This article sets forth a study to identify and summaries the various techniques for improving the performance (COP) and energy efficiency of the domestic refrigerators. The techniques which are used for improving the performance, such as use of the suction line heat exchanger (SLHX), thermal storage materials (PCMs) and variation in a geometric configuration of the refrigerator condensers. The main purpose of this study to quantify the influence of these techniques for performance and energy efficiency of the refrigerators and to develop an energy efficient refrigerator. The previous results indicate that these techniques have a positive influence on performance and energy efficiency of the refrigerators. This article comments that the use of such techniques can improve the performance (COP) and energy efficiency up to 30% compared to the existing refrigerator configuration.
This article reports an experimental study on the energy efficiency of domestic refrigerator with a helical coil condenser (Elliptical configuration with a minor axis 76mm and major axis 381mm) and conventional refrigerator. The Elliptical configuration of condenser coil helps to improve the turbulence of the fluid (both refrigeration and air side). The air side turbulence in elliptical configuration is more than conventional condenser. This increases the heat transfer rate and correspondingly the sub-cooling of the refrigerant after the condenser. The results show that the heat loss is increased in refrigerator B compared to other two configurations and energy consumption per day is decreasing for same operating conditions.