Pengbai Xu

Pengbai Xu

Auto-generated profile, based on publicly available information

Pengbai Xu


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2022 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
JZJiarui Zhang
Jiarui Zhang
XDXinyong Dong
Xinyong Dong
PXPengbai Xu
Pengbai Xu
DLDajuan Lv
Dajuan Lv
JYJun Yang
Jun Yang
YQYuwen Qin
Yuwen Qin
An optical fiber thermal anemometer with a light source-heated Fabry–Perot interferometer (FPI) is proposed. The FPI is fabricated on the tip of a single-mode fiber using an ultraviolet-cured adhesive. A broadband light source acts as a heating light source as well, eliminating the need for a heating resistor or a pump laser which are usually required in optical fiber thermal anemometers. The interference fringe of the FPI shifts with airflow velocity because airflow not only reduces temperature of the FPI but also introduces strain due to wind force. Airflow velocity is therefore measured by detecting wavelength shift of the interference fringe. In the experiment, a high sensitivity up to −3.13 nm/(m·s −1 ) was achieved at the low velocity region, reducing to ∼−0.2 nm/(m·s −1 ) at the high velocity region within the measurement range of 0–7 m/s. The response and recovery time is 250 and 580 ms, respectively. It is worth noting that the anemometer maintains a relatively high sensitivity at the high velocity region due to the contribution of wind force effect that makes it outperform most of the fiber thermal anemometers.

15 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YZYu Jun Zhe
Yu Jun Zhe
PXPengbai Xu
Pengbai Xu
ZYZhangjun Yu
Zhangjun Yu
KWKunhua Wen
Kunhua Wen
JYJun Yang
Jun Yang
YQYuwen Qin
Yuwen Qin
Submarine optical cables, utilized as fiber-optic sensors for seismic monitoring, are gaining increasing interest because of their advantages of extending the detection coverage, improving the detection quality, and enhancing long-term stability. The fiber-optic seismic monitoring sensors are mainly composed of the optical interferometer, fiber Bragg grating, optical polarimeter, and distributed acoustic sensing, respectively. This paper reviews the principles of the four optical seismic sensors, as well as their applications of submarine seismology over submarine optical cables. The advantages and disadvantages are discussed, and the current technical requirements are concluded, respectively. This review can provide a reference for studying submarine cable-based seismic monitoring.

15 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YZYusong Zhong
Yusong Zhong
PXPengbai Xu
Pengbai Xu
JYJun Yang
Jun Yang
XDXinyong Dong
Xinyong Dong
An optical fiber Fabry–Perot interferometer (FPI) is constructed for relative humidity measurement by fusion splicing a short hollow core fiber (HCF) to the end of a single-mode fiber and coating the tip of the HCF with a layer of gelatin. The thickness of the gelatin film changes with ambient humidity level and modulates cavity length of the FPI. Humidity measurement is therefore realized by measuring the wavelength shift of the interreference fringe. RH sensitivity of 0.192 nm/%RH is achieved within a measurement range of 20–80%RH. Dynamic measurement shows a response and recovery time of 240 and 350 ms, respectively. Sensor performance testing shows good repeatability and stability at room temperature but also reveals slight dependence of the RH sensitivity on environmental temperature. Therefore, a fiber Bragg grating is cascaded to the FPI sensing probe to monitor temperature simultaneously with temperature sensitivity of 10 pm/°C.

3 December 2020 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
PXPengbai Xu
Pengbai Xu
CPChao Pang
Chao Pang
XDXinyong Dong
Xinyong Dong
YQYuwen Qin
Yuwen Qin
YDYongkang Dong
Yongkang Dong
In this article, fast measurement of Brillouin optical time-domain reflectometry (BOTDR) based on a linearly frequency modulated (LFM) pulse and a digital matched filter is studied theoretically and demonstrated experimentally. The Brillouin frequency shift (BFS) change is detected by measuring the time shift of the Brillouin gain spectrum (BGS) along the time axis instead of the frequency shift, as in traditional BOTDR. In the experiment, we propose to use a positive- and negative-swept pulse, named bipolar-chirped pulse pair (BPP), to determine the BFS change with high accuracy. A BGS acquisition of up to 320 Hz is obtained for a fiber length of 2 km with a strain measurement accuracy of ±8 με. Strain measurements in a range of up to 10000 με are conducted, and the resulting strain coefficient is equal to 0.048 MHz/MHz/με, which matches that of standard single-mode fibers. The BPP-BOTDR technique is an intrinsic one-end-injection truly distributed system that exhibits high measurement speed and high accuracy, which may pave the way for various BOTDR applications.

13 February 2023 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
PXPengbai Xu
Pengbai Xu
YPYihao Peng
Yihao Peng
KWKunhua Wen
Kunhua Wen
YSYuehui Sun
Yuehui Sun
XDXinyong Dong
Xinyong Dong
YQYuwen Qin
Yuwen Qin
Temperature–strain cross-sensitivity and bending-induced optical loss are two major limitations that challenge the in-situ application of distributed optical fiber sensors. Researchers have attempted to solve these two issues but seldom can overcome both. This paper proposes a novel bending-loss-resistant distributed temperature and strain discriminative sensor that is based on a 98 mol% germania-doped few-mode fiber and a standard Brillouin optical time-domain analysis setup. In a proof-of-concept demonstration, distributed temperature and strain discriminative measurements were conducted under a bending radius of 0.6 cm, where the maximum temperature and strain deviation were 2.78 ℃ and 33.2 μϵ , respectively.

9 December 2020 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
ZYZhangjun Yu
Zhangjun Yu
CHChengcheng Hou
Chengcheng Hou
YYYonggui Yuan
Yonggui Yuan
PXPengbai Xu
Pengbai Xu
XDXinyong Dong
Xinyong Dong
YQYuwen Qin
Yuwen Qin
Polarization extinction ratio (PER) is a quantitative indicator of the polarization-maintaining (PM) ability of a device. In this work, we present a distributed PER measurement method based on white-light interferometry. It can accurately measure the PER distribution of a PM device even in the presence of strong polarization crosstalk. We show that the distributed PER can be expressed as the reciprocal of the accumulated polarization crosstalk along the device. Thus, the PER distribution of a PM device can be calculated from the distributed polarization crosstalk. In the presence of strong polarization crosstalk, we introduced a concept of polarization crosstalk induced loss to prove that there is a significant error of the measured distributed polarization crosstalk. The error can be accurately estimated and be calibrated out from the measurement result. To verify the measurement method and the calibration accuracy, we used a commercial PER meter that can only measure the total PER of a device as the reference. We simulated a quasi-distributed PER device under test (DUT) by successively splicing 15 pieces of PM fibers and measured its total PER after splicing each piece of fiber. The calculated distributed PER of the DUT after error calibration matches well with the quasi-distributed result at the corresponding locations. Finally, we applied the method to measure the distributed PER and total PER of a PM fiber coil. After error calibration, the residual error (i.e., the difference with the commercial PER meter) in the total PER, thus of the distributed PER, is less than 0.1 dB.