Considering that vehicle exhaust contributes the majority of nitrogen oxides (NOx), which is harmful to environment and climate it is important to measure NOx concentrations in sustainable developments. This paper proposes to apply spectroscopic gas sensing methods and an innovative deep learning network algorithm for obtaining high-precision NOx data. Tha adopted mid-infrared sensor technology is based on mid-infrared spectroscopy combined with an advanced substrate-integrated hollow waveguide (iHWG) sensing interface. Using extreme learning machine (ELM) algorithms with an exceptionally fast learning speed when dealing with big data problems next to excellent generalization abilities, a deep learning network for regressing NOx concentrations was implemented. Moreover, to further improve the regression performance the proposed deep ELM was provided with features derived from supervised learning improving its ability to address target constituents. Finally, experiments with gas mixtures containing three species relevant in exhaust emission monitoring have confirmed the utility of the developed approach.
7 December 2022 in Journal of Lightwave Technology
Noise induced by the fluctuation of laser phase, frequency, intensity, etc., can deteriorate the point spread function (PSF) in distributed optical fiber sensing and testing systems, which is the core concern for measurement performance, such as measurement spatial resolution, length range, accuracy and dynamic range. In this paper, we review the development of noise compensation methods for improving the PSF in optical fiber frequency sweeping interferometry (OFFSI) systems and provide a reference to select appropriate compensation methods in different applications (e.g., fiber optics component characterization, optical fiber network diagnosis). A discussion of noise impacts on PSF is made, including laser source phase noise, laser source intensity noise and ambient noise. The most serious noise is the laser source phase noise involved in frequency tunable lasers, including deterministic frequency tuning nonlinearity and stochastic laser phase noise. Also, a comprehensive and detailed classification of the compensation strategies for different noise is provided according to the dominant noise in the laser source. Recent progress on each kind of compensation method is analyzed based on the principles, performance, advantages and limitations, and a comparison of compensation methods is presented. Finally, an overview of trends and future developments is given.
Submarine optical cables, utilized as fiber-optic sensors for seismic monitoring, are gaining increasing interest because of their advantages of extending the detection coverage, improving the detection quality, and enhancing long-term stability. The fiber-optic seismic monitoring sensors are mainly composed of the optical interferometer, fiber Bragg grating, optical polarimeter, and distributed acoustic sensing, respectively. This paper reviews the principles of the four optical seismic sensors, as well as their applications of submarine seismology over submarine optical cables. The advantages and disadvantages are discussed, and the current technical requirements are concluded, respectively. This review can provide a reference for studying submarine cable-based seismic monitoring.
30 December 2020 in Journal of Lightwave Technology
Distributed polarization measurement is a significant way to evaluate polarization-maintaining fiber. It can assess the fiber's polarization preserving ability and locate internal defects and external perturbations of a long-distance PM fiber. Distributed polarization crosstalk of a fiber-optic polarization device accurately describes its time-dependent optical performance. Therefore, distributed polarization measurement technology can be used to predict and prevent the performance degradation and failure. However, the remaining shortcomings of existing measurement methods are low dynamic range, short measurement length, inadequate spatial resolution, and low diagnostic ability. This paper reviews recent advances in solving the above issues and presents ways to obtain high performances: a dynamic range $\gt 90 {\text {dB}}$ , a measurement length $\gt 10 {\text {km}}$ , a full range spatial resolution $\lt 10 {\text {cm}}$ , and developments in time domain, frequency domain, and time-frequency domain diagnosis methods. All these high-performance techniques have led to more effective diagnosis of fiber optic sensing coils. This can be demonstrated by a series of comparative measurements and analysis of three PM fiber optic sensing coils in various configurations such as a randomly-wound spool of fiber and a free-standing coil quadrupole-pattern-wound from it, a second coil with and without a flange at various temperatures, and a third coil spliced to a Y waveguide. Each is one of the key configurations during the production processes or the application of the fiber sensing coil. The technical progress reviewed here will greatly promote the development, production, and application of fiber sensing coils.
A dual cross-axis interference polarization-maintaining fiber interferometer (DCAI-PMFI) for simultaneous measurement of strain and temperature is proposed. By using the cross-interference of the fast and slow axes in the polarization-maintaining fiber interferometer with dual axis independent detection, common path dual cross-axis interferometers (DCAIs) are realized. Since the fast and slow axes are different in refractive index and thermo-optic coefficient, the DCAIs have different phase sensitivities to strain and temperature. A sensitivity matrix for simultaneous measurement of temperature and strain is constructed. The temperature phase sensitivities can be adjusted by changing the length ratio of two arms of the DCAI-PMFI to optimize the decoupling performance of temperature and strain. It is found that the temperature sensitivities are opposite signs when the length ratio of two arms is between the ratio of the temperature optical path coefficients of the fast and slow axis and its reciprocal, and the best measurement resolution can be obtained when two arms are equal in length. In the experimental setup of DCAI-PMFI with equal length of two arms, the strain sensitivities are 1.5648 rad/ μϵ and 1.5790 rad/ μϵ respectively at 0.35m strain sensing fiber, the temperature sensitivities are −25.4990 rad/°C and 24.6000 rad/°C respectively at 10m arm length, the resolutions are 2.4 μϵ in strain and 0.02°C in temperature. The experimental results show that the proposed sensor can solve the crosstalk between strain and temperature of interferometer, and can be applied to various interferometric fiber sensors without changing the topology.
10 April 2023 in IEEE Transactions on Instrumentation and Measurement
Simultaneous measurement of thickness and refractive index is an important quality control scheme in high-end fabrication. However, the precise measurement of large-range thickness is still technically difficult. In this paper, we propose a high-precision simultaneous measurement method of thickness and group refractive index using differential white light interferometry. Using the bi-directional white light interferometer with a high dynamic range, we can get access to the optical paths on both sides of the specimen. We evaluate the performance of the proposed method by measuring specimens of three different materials, with different thicknesses ranging from 200 μm to 2000 μm. The measurement data are in good agreement with the nominal thickness, and the standard deviations of repeated measurements are ≤0.009 μm and ≤1.63×10 -4 RIU for thickness and group refractive index respectively. In addition, we evaluate the impact of the temperature change on the group refractive index. A quasi-linear relationship between group refractive index and temperature is observed, and the slope of linear fit of silicon specimen around 20 °C is about 3.29×10 -4 RIU/°C@1310 nm. We also analyze and summarize the main factors which may introduce uncertainty in the measurement results. The expanded uncertainties ( k =2) of measured thickness and group refractive index are ≤4.21×10 -2 μm and ≤7.84×10 -4 RIU respectively. The repeatability and uncertainty of group refractive index measurement both decrease as the thickness of specimen increases.