Alexei Ossadtchi

Dr. Alexei Ossadtchi

Center for Bioelectric Interfaces, HSE University

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2019 in Frontiers in Neuroinformatics
Verified
Journal Article
Open access
PDF file
KVKsenia Volkova
Ksenia Volkova
MLMikhail Lebedev
Mikhail Lebedev
AKAlexander Kaplan
Alexander Kaplan
AOAlexei Ossadtchi
Alexei Ossadtchi
Electrocorticography (ECoG) holds promise to provide efficient neuroprosthetic solutions for people suffering from neurological disabilities. This recording technique combines adequate temporal and spatial resolution with the lower risks of medical complications compared to the other invasive methods. ECoG is routinely used in clinical practice for preoperative cortical mapping in epileptic patients. During the last two decades, research utilizing ECoG has considerably grown, including the paradigms where behaviorally relevant information is extracted from ECoG activity with decoding algorithms of different complexity. Several research groups have advanced toward the development of assistive devices driven by brain-computer interfaces (BCIs) that decode motor commands from multichannel ECoG recordings. Here we review the evolution of this field and its recent tendencies, and discuss the potential areas for future development.

1 December 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
ABAnastasiia Belinskaia
Anastasiia Belinskaia
NSNikolai Smetanin
Nikolai Smetanin
MLMikhail Lebedev
Mikhail Lebedev
AOAlexei Ossadtchi
Alexei Ossadtchi
Objective. Feedback latency was shown to be a critical parameter in a range of applications that imply learning. The therapeutic effects of neurofeedback (NFB) remain controversial. We hypothesized that often encountered unreliable results of NFB intervention could be associated with large feedback latency values that are often uncontrolled and may preclude the efficient learning. Approach. We engaged our subjects into a parietal alpha power unpregulating paradigm facilitated by visual NFB based on the individually extracted envelope of the alpha-rhythm at P4 electrode. NFB was displayed either as soon as electroencephalographic (EEG) envelope was processed, or with an extra 250 or 500 ms delay. The feedback training consisted of 15 two-minute long blocks interleaved with 15 s pauses. We have also recorded 2 min long baselines immediately before and after the training. Main results. The time course of NFB-induced changes in the alpha rhythm power clearly depended on NFB latency, as shown with the adaptive Neyman test. NFB had a strong effect on the alpha-spindle incidence rate, but not on their duration or amplitude. The sustained changes in alpha activity measured after the completion of NFB training were negatively correlated to latency, with the maximum change for the shortest tested latency and no change for the longest. Significance. Here we for the first time show that visual NFB of parietal EEG alpha-activity is efficient only when delivered to human subjects at short latency, which guarantees that NFB arrives when an alpha spindle is still ongoing. Such a considerable effect of NFB latency on the alpha-activity temporal structure could explain some of the previous inconsistent results, where latency was neither controlled nor documented. Clinical practitioners and manufacturers of NFB equipment should add latency to their specifications while enabling latency monitoring and supporting short-latency operations.

19 June 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AOAlexei Ossadtchi
Alexei Ossadtchi
TSTatiana Shamaeva
Tatiana Shamaeva
EOElizaveta Okorokova
Elizaveta Okorokova
VMVictoria Moiseeva
Victoria Moiseeva
MLMikhail Lebedev
Mikhail Lebedev
Although the first experiments on alpha-neurofeedback date back nearly six decades ago, when Joseph Kamiya reported successful operant conditioning of alpha-rhythm in humans, the effectiveness of this paradigm in various experimental and clinical settings is still a matter of debate. Here, we investigated the changes in EEG patterns during a continuously administered neurofeedback of P4 alpha activity. Two days of neurofeedback training were sufficient for a significant increase in the alpha power to occur. A detailed analysis of these EEG changes showed that the alpha power rose because of an increase in the incidence rate of alpha episodes, whereas the amplitude and the duration of alpha oscillations remained unchanged. These findings suggest that neurofeedback facilitates volitional control of alpha activity onset, but alpha episodes themselves appear to be maintained automatically with no volitional control – a property overlooked by previous studies that employed continuous alpha-power neurofeedback. We propose that future research on alpha neurofeedback should explore reinforcement schedules based on detection of onsets and offsets of alpha waves, and employ these statistics for exploration and quantification of neurofeedback induced effects.

2 March 2021 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
APArtur Petrosyan
Artur Petrosyan
MSMikhail Sinkin
Mikhail Sinkin
MLMikhail Lebedev
Mikhail Lebedev
AOAlexei Ossadtchi
Alexei Ossadtchi
Objective. Brain–computer interfaces (BCIs) decode information from neural activity and send it to external devices. The use of Deep Learning approaches for decoding allows for automatic feature engineering within the specific decoding task. Physiologically plausible interpretation of the network parameters ensures the robustness of the learned decision rules and opens the exciting opportunity for automatic knowledge discovery. Approach. We describe a compact convolutional network-based architecture for adaptive decoding of electrocorticographic (ECoG) data into finger kinematics. We also propose a novel theoretically justified approach to interpreting the spatial and temporal weights in the architectures that combine adaptation in both space and time. The obtained spatial and frequency patterns characterizing the neuronal populations pivotal to the specific decoding task can then be interpreted by fitting appropriate spatial and dynamical models. Main results. We first tested our solution using realistic Monte-Carlo simulations. Then, when applied to the ECoG data from Berlin BCI competition IV dataset, our architecture performed comparably to the competition winners without requiring explicit feature engineering. Using the proposed approach to the network weights interpretation we could unravel the spatial and the spectral patterns of the neuronal processes underlying the successful decoding of finger kinematics from an ECoG dataset. Finally we have also applied the entire pipeline to the analysis of a 32-channel EEG motor-imagery dataset and observed physiologically plausible patterns specific to the task. Significance. We described a compact and interpretable CNN architecture derived from the basic principles and encompassing the knowledge in the field of neural electrophysiology. For the first time in the context of such multibranch architectures with factorized spatial and temporal processing we presented theoretically justified weights interpretation rules. We verified our recipes using simulations and real data and demonstrated that the proposed solution offers a good decoder and a tool for investigating motor control neural mechanisms.

15 June 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MPMikhail Petrenko
Mikhail Petrenko
SDSergei P. Dmitriev
Sergei P. Dmitriev
APAnatoly S. Pazgalev
Anatoly S. Pazgalev
AOAlexei Ossadtchi
Alexei Ossadtchi
AVAnton Vershovskii
Anton Vershovskii
Magnetic sensors developed for application in magnetoencephalography must meet a number of requirements; the main ones are compactness, sensitivity and response speed. We present a quantum optically pumped atomic sensor with cell volume of 0.5 cm 3 that meets these requirements and is operable in nonzero magnetic fields. The ultimate sensitivity of the sensor was estimated as (using the criteria of the ratio of the slope of the magnetic resonance signal to the shot noise spectral density) to be better than 5 fT/ √Hz. The actual sensitivity, measured in a gradiometric scheme, reaches 13 fT/ √Hz per sensor. We also present a novel and fast algorithm for optimization of the geometric properties of non-zero field sensor array with respect to maximization of the information transfer rate for cortical sources.

1 December 2018 in NeuroImage
Verified
Journal Article
Closed access
AOAlexei Ossadtchi
Alexei Ossadtchi
DAD. Altukhov
D. Altukhov
KJK. Jerbi
K. Jerbi