Marcello Mancini

Dr. Marcello Mancini

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2009 in Metabolism
Verified
Journal Article
Closed access
MMMarcello Mancini
Marcello Mancini
APAnna Prinster
Anna Prinster
GAGiovanni Annuzzi
Giovanni Annuzzi
RLRaffaele Liuzzi
Raffaele Liuzzi
RGRosalba Giacco
Rosalba Giacco
MSMarco Salvatore
Marco Salvatore

12 October 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MMMarcello Mancini
Marcello Mancini
AMAngelo Salomone Megna
Angelo Salomone Megna
MRMonica Ragucci
Monica Ragucci
MLMassimo De Luca
Massimo De Luca
GMGiuseppina Marino Marsilia
Giuseppina Marino Marsilia
MIMariarosaria Incoronato
Mariarosaria Incoronato
The presence of significant fibrosis is an indicator for liver disease staging and prognosis. The aim of the study was to determine reproducibility of real-time shear wave elastography using a hepatic biopsy as the reference standard to identify patients with chronic liver disease. Forty patients with chronic liver disease and 12 normal subjects received shear wave elastography performed by skilled operators. Interoperator reproducibility was studied in 29 patients. Fibrosis was evaluated using the Metavir score. The median and range shear wave elastography values in chronic liver disease subjects were 6.15 kPa and 3.14–16.7 kPa and were 4.49 kPa and 2.92–7.32 kPa in normal subjects, respectively. With respect to fibrosis detected by liver biopsy, shear wave elastography did not change significantly between F0 and F1 (p = 0.334), F1 and F2 (p = 0.611), or F3 and F4 (0.327); a significant difference was observed between the F0-F2 and F3-F4 groups (p = 0.002). SWE also correlated with inflammatory activity (Rs = 0.443, p = 0.0023) and ALT levels (Rs = 0.287, p = 0.0804). Age, sex and body mass index did not affect shear wave elastography measurements. Using receiver operator characteristic curves, two threshold values for shear wave elastography were identified: 5.62 kPa for patients with fibrosis (≥F2; sensitivity 80%, specificity 69.4%, and accuracy 77%) and 7.04 kPa for patients with severe fibrosis (≥F3; sensitivity 88.9%, specificity 81%, and accuracy 89%). Overall interobserver agreement was excellent and was analysed using an interclass correlation coefficient (0.94; CI 0.87–0.97).This study shows that shear wave elastography executed by skilled operators can be performed on almost all chronic liver disease patients with high reproducibility. It is not influenced by age, sex or body mass index, identifies severely fibrotic patients and is also related to inflammatory activity.

26 October 2011 in BMC Neurology
Verified
Journal Article
Open access
PDF file
SBStefano Bastianello
Stefano Bastianello
ARAlfredo Romani
Alfredo Romani
GVGisela Viselner
Gisela Viselner
ETEnrico Colli Tibaldi
Enrico Colli Tibaldi
EGElisabetta Giugni
Elisabetta Giugni
RBRoberto Bergamaschi
Roberto Bergamaschi
Chronic cerebrospinal venous insufficiency (CCSVI) has recently been reported to be associated with multiple sclerosis (MS). However, its actual prevalence, possible association with specific MS phenotypes, and potential pathophysiological role are debated.

1 March 2012 in Radiology
Verified
Journal Article
Closed access
MMMarcello Mancini
Marcello Mancini
VMVincenzo Brescia Morra
Vincenzo Brescia Morra
ODOrlando Di Donato
Orlando Di Donato
VMValentina Maglio
Valentina Maglio
RLRoberta Lanzillo
Roberta Lanzillo
MSMarco Salvatore
Marco Salvatore
Purpose: To assess cerebral circulation times (CCTs) in patients with multiple sclerosis (MS) and control subjects by using contrast material-enhanced ultrasonography (US) to determine whether vascular abnormalities can be detected in this disease. Materials and Methods: This study was approved by the local ethics committee, and informed consent was obtained from all subjects. One hundred three patients with MS and 42 control subjects underwent extracranial and transcranial venous echo-color Doppler ultrasonography (US) and contrast-enhanced US. CCT was defined as the difference in arrival time of the US contrast agent bolus between the carotid artery and the internal jugular vein. The presence of chronic cerebrospinal venous insufficiency (CCSVI) was defined according to previously reported criteria for the extracranial and transcranial US techniques. Nonparametric statistics, including the Mann-Whitney U test and the Kruskal-Wallis analysis of variance, were used to compare contrast-enhanced US parameters between groups. Results: The longest and average CCTs were substantially prolonged in patients with MS compared with those in control subjects (median longest CCT in patients with MS, 6.47 seconds [range, 3.29-29.24 seconds]; that in control subjects, 5.54 seconds [range, 2.57-7.63 seconds]; P < .001; median average CCT in patients with MS, 5.76 seconds [range, 2.64-17.51 seconds]; that in control subjects, 5.01 seconds [range, 2.57-7.06 seconds]; P < .002). No correlation was found between CCTs and clinical parameters. The prevalence of CCSVI was higher in patients with MS than in control subjects (77% vs 28%, P < .0001). CCT was not significantly different between patients with MS who had CCSVI and patients with MS who did not (P = .182). Conclusion: These results suggest that contrast-enhanced US with CCT assessment may have a role in the evaluation of cerebral blood flow in patients with MS and that a vascular impairment could be associated with MS. The finding of a prolonged CCT at contrast-enhanced US does not result from outflow impairment. Further studies are required to verify these observations and to clarify if CCT and CCSVI have any physiologic and clinical relevance in MS

11 June 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MMMarcello Mancini
Marcello Mancini
AGAdelaide Greco
Adelaide Greco
ETEnrico Tedeschi
Enrico Tedeschi
Giuseppe PalmaGiuseppe Palma
Giuseppe Palma
MRMonica Ragucci
Monica Ragucci
MSMarco Salvatore
Marco Salvatore
To characterize the anatomy of the venous outflow of the mouse brain using different imaging techniques. Ten C57/black male mice (age range: 7-8 weeks) were imaged with high-frequency Ultrasound, Magnetic Resonance Angiography and ex-vivo Microcomputed tomography of the head and neck. Under general anesthesia, Ultrasound of neck veins was performed with a 20MHz transducer; head and neck Magnetic Resonance Angiography data were collected on 9.4T or 7T scanners, and ex-vivo Microcomputed tomography angiography was obtained by filling the vessels with a radiopaque inert silicone rubber compound. All procedures were approved by the local ethical committee. The dorsal intracranial venous system is quite similar in mice and humans. Instead, the mouse Internal Jugular Veins are tiny vessels receiving the sigmoid sinuses and tributaries from cerebellum, occipital lobe and midbrain, while the majority of the cerebral blood, i.e. from the olfactory bulbs and fronto-parietal lobes, is apparently drained through skull base connections into the External Jugular Vein. Three main intra-extracranial anastomoses, absent in humans, are: 1) the petrosquamous sinus, draining into the posterior facial vein, 2) the veins of the olfactory bulb, draining into the superficial temporal vein through a foramen of the frontal bone 3) the cavernous sinus, draining in the External Jugular Vein through a foramen of the sphenoid bone. The anatomical structure of the mouse cranial venous outflow as depicted by Ultrasound, Microcomputed tomography and Magnetic Resonance Angiography is different from humans, with multiple connections between intra- and extra- cranial veins.

13 December 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
ASAnnachiara Sarnella
Annachiara Sarnella
YFYlenia Ferrara
Ylenia Ferrara
CTCristina Terlizzi
Cristina Terlizzi
SASandra Albanese
Sandra Albanese
Serena MontiSerena Monti
Serena Monti
MMMarcello Mancini
Marcello Mancini
The chicken embryo has emerged as a valuable model for preclinical studies due to its unique combination of accessibility, affordability, and relevance to human biology. Its rapid development, external growth environment, and clear structural visibility offer distinct advantages over traditional mammalian models. These features facilitate the study of real-time biological processes, including tissue development, tumor growth, angiogenesis, and drug delivery, using various imaging modalities, such as optical imaging, magnetic resonance imaging, positron emission tomography, computed tomography, and ultrasound. The chicken embryo model also minimizes ethical concerns compared to mammalian models, as it allows for early-stage research without the complexity of a fully developed animal. Moreover, its ability to integrate human tumor cells into xenograft models provides a reliable platform for cancer research, enabling high-throughput screening of therapeutic interventions and tracking molecular dynamics in vivo. Advances in molecular imaging techniques further enhance the resolution and depth of data obtained from these studies, offering insights into cellular and molecular mechanisms underlying disease. Given its versatility, cost-effectiveness, and translational potential, the chicken embryo represents a promising tool for advancing preclinical research, particularly in drug development, cancer biology, and regenerative medicine.