Johannes Van Dijk

Dr. Johannes Van Dijk

Kempenhaeghe, Heeze, The Netherlands
+2
orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1990 in Free Radical Biology and Medicine
Verified
Journal Article
Closed access
JSJos.M. Simons
Jos.M. Simons
BHBert 't Hart
Bert 't Hart
TCTheo.R.A.M. Ip Vai Ching
Theo.R.A.M. Ip Vai Ching
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
RLRudi P. Labadie
Rudi P. Labadie

1 January 2004 in Journal of Applied Physiology
Verified
Journal Article
Closed access
BLB. G. Lapatki
B. G. Lapatki
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
IJI. E. Jonas
I. E. Jonas
MZM. J. Zwarts
M. J. Zwarts
DSD. F. Stegeman
D. F. Stegeman
Although the value of high-density surface electromyography (sEMG) has already been proven in fundamental research and for specific diagnostic questions, there is as yet no broad clinical application. This is partly due to limitations of construction principles and application techniques of conventional electrode array systems. We developed a thin, highly flexible, two-dimensional multielectrode sEMG grid, which is manufactured by using flexprint techniques. The material used as electrode carrier (Polyimid, 50 μm thick) allows grids to be cut out in any required shape or size. One universal grid version can therefore be used for many applications, thereby reducing costs. The reusable electrode grid is attached to the skin by using specially prepared double-sided adhesive tape, which allows the selective application of conductive cream only directly below the detection surfaces. To explore the practical possibilities, this technique was applied in single motor unit analysis of the facial musculature. The high mechanical flexibility allowed the electrode grid to follow the skin surface even in areas with very uneven contours, resulting in good electrical connections in the whole recording area. The silverchloride surfaces of the electrodes and their low electrode-to-skin impedances guaranteed high baseline stability and a low signal noise level. The electrode-to-skin attachment proved to withstand saliva and great tensile forces due to mimic contractions. The inexpensive, universally adaptable and minimally obstructive sensor allows the principal advantages of high-density sEMG to be extended to all skeletal muscles accessible from the skin surface and may lay the foundation for more broad clinical application of this noninvasive, two-dimensional sEMG technique.

1 April 2012 in Neuromuscular Disorders
Verified
Journal Article
Closed access
MJMerel Jansen
Merel Jansen
NANens van Alfen
Nens van Alfen
RSRia Nijhuis-van der Sanden
Ria Nijhuis-van der Sanden
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
SPSigrid Pillen
Sigrid Pillen
IGImelda J.M. de Groot
Imelda J.M. de Groot

1 October 2007 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
BKBert U. Kleine
Bert U. Kleine
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
BLBernd G. Lapatki
Bernd G. Lapatki
MZMachiel J. Zwarts
Machiel J. Zwarts
DSDick F. Stegeman
Dick F. Stegeman

19 March 2009 in Muscle & Nerve
Verified
Journal Article
Closed access
PDF file
SPSigrid Pillen
Sigrid Pillen
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
GWGert Weijers
Gert Weijers
WRWilma Raijmann
Wilma Raijmann
CKChris L. de Korte
Chris L. de Korte
MZMachiel J. Zwarts
Machiel J. Zwarts

20 November 2018 in Neurology
Verified
Journal Article
Open access
PDF file
JAJohan Arends
Johan Arends
RTRoland D. Thijs
Roland D. Thijs
TGThea Gutter
Thea Gutter
CUConstantin Ungureanu
Constantin Ungureanu
PCPierre Cluitmans
Pierre Cluitmans
TCthe Dutch Tele-Epilepsy Consortium
the Dutch Tele-Epilepsy Consortium
Objective To develop and prospectively evaluate a method of epileptic seizure detection combining heart rate and movement. Methods In this multicenter, in-home, prospective, video-controlled cohort study, nocturnal seizures were detected by heart rate (photoplethysmography) or movement (3-D accelerometry) in persons with epilepsy and intellectual disability. Participants with >1 monthly major seizure wore a bracelet (Nightwatch) on the upper arm at night for 2 to 3 months. Major seizures were tonic-clonic, generalized tonic >30 seconds, hyperkinetic, or others, including clusters (>30 minutes) of short myoclonic/tonic seizures. The video of all events (alarms, nurse diaries) and 10% completely screened nights were reviewed to classify major (needing an alarm), minor (needing no alarm), or no seizure. Reliability was tested by interobserver agreement. We determined device performance, compared it to a bed sensor (Emfit), and evaluated the caregivers’ user experience. Results Twenty-eight of 34 admitted participants (1,826 nights, 809 major seizures) completed the study. Interobserver agreement (major/no major seizures) was 0.77 (95% confidence interval [CI] 0.65–0.89). Median sensitivity per participant amounted to 86% (95% CI 77%–93%); the false-negative alarm rate was 0.03 per night (95% CI 0.01–0.05); and the positive predictive value was 49% (95% CI 33%–64%). The multimodal sensor showed a better sensitivity than the bed sensor (n = 14, median difference 58%, 95% CI 39%–80%, p < 0.001). The caregivers9 questionnaire (n = 33) indicated good sensor acceptance and usability according to 28 and 27 participants, respectively. Conclusion Combining heart rate and movement resulted in reliable detection of a broad range of nocturnal seizures.