Restenosis after percutaneous transluminal angioplasty (PTA) of the superficial femoral artery (SFA) may occur in 45% of patients at 2 years follow-up. Paclitaxel-coated balloons have been found to reduce neointimal hyperplasia, and thus reduce restenosis. Recently, the Legflow® paclitaxel-coated balloon (Cardionovum Sp.z.o.o., Warsaw, Poland) (LPEB) has been introduced. This balloon is covered with shellac, a Food and Drug Administration (FDA) approved natural resin, to obtain an equally distributed tissue concentration of paclitaxel. The RAPID trial is designed to assess restenosis after PTA using the Legflow balloon combined with nitinol stenting versus uncoated balloons with nitinol stenting in SFA lesions >5 cm.
Critical limb ischemia (CLI) is the clinical end stage of peripheral artery disease and is associated with high amputation, mortality rates and poor quality of life. For CLI patients with no revascularization options, venous arterialization could be an alternative technique for limb salvage. A systematic review and meta-analysis published in 2017 concluded that venous arterialization may be considered a viable alternative. A recent development, is the Percutaneous Deep Vein Arterialization (pDVA), that is CE-marked and currently under investigation of the FDA. This procedure, called LimFlow, is a novel, minimally invasive, endovascular approach to perform a venous arterialization procedure. The limited evidence for its use necessitates a scientific judgement of the pDVA. Therefore, we initiated a prospective clinical post market trial to investigate the outcome of the pDVA in no-option critical limb ischemia. The objective of this prospective study is to collect “real-life” clinical data among a population of patients treated with the pDVA in order to evaluate the clinical effectiveness and safety of the LimFlow System in patients with no-option critical limb ischemia. This study is a single-arm, open-label, prospective, post-market follow-up study to be conducted on up to fifty (50) eligible patients with a twelve-month follow-up period. The Primary endpoint is measured by amputation free survival. Secondary endpoints are complete wound healing, primary and secondary patency, limb salvage, renal function and technical and procedural success. Patients will be assessed at regular intervals during one year after the initial percutaneous deep vein arterialization procedure through clinical evaluation and self-completed questionnaires. The last decade several studies have been published with promising results and the number of treated patients has considerably grown. Venous arterialization could be a valuable treatment option in patients with often no other options than amputation of the affected limb. The first results in men are promising although more research and long term follow up is needed to establish the efficacy of this new treatment modality. With this prospective study, we evaluate the clinical effectiveness and safety in patients with no-option CLI treated with the pDVA (LimFlow System). NCT03321552 .
Background: Computed tomography (CT) is considered the imaging modality of choice to diagnose pulmonary arteriovenous malformations PAVMs. The drawback of this technique is that it requires ionizing radiation. Magnetic resonance (MR) imaging does not have the limitation, but little is known about the performance of MR compared to CT for the detection of PAVMs. The aim of this study is to investigate the sensitivity of contrast-enhanced MR angiography (CE-MRA) in the detection of PAVMs with feeding artery diameters (FAD) > 2 mm. Methods: Patients with a grade 2 or 3 shunt on screening transthoracic contrast echocardiography (TTCE) were asked to participate. Included patients underwent chest CT and CE-MRA. CT was considered the reference standard. CT and CE-MRA scans were anonymized and assessed for the presence of PAVMs with FAD > 2 mm by one and two readers respectively. Data analysis was performed on per patient and per PAVM basis. Results: Fifty-three patients were included. 105 PAVMs were detected on CT, 45 with a FAD ≥ 2 mm. In per patient analysis, sensitivity and specificity of CE-MRA were 92% and 97% respectively for reader 1 and 92% and 62% for reader 2. Negative and positive predictive value (NPV/PPV) were 93% and 96% for R1 and 90% and 67% for R2. In per PAVM analysis, sensitivity, specificity, NPV and PPV were 96%, 99%, 100% and 86% for R1 and 93%, 96%, 100% and 56% for R2, respectively. Conclusions: CE-MRA has excellent sensitivity and NPV for detection of PAVMs with FAD ≥ 2 mm and can therefore be used to detect these PAVMs. We are hopeful that future advancements in CE-MRA technology will reduce false positive rates and allow for more broad use of CE-MRA in PAVM diagnosis and management.
Endovascular iliac artery interventions rely on the use of two-dimensional digital subtraction angiographies with an iodinated contrast agent and ionizing radiation. The amount of iodinated contrast agent should be limited because of its potentially nephrotoxic effects. Three-dimensional (3D) image fusion requires registration of a preprocedural magnetic resonance angiogram (MRA) or computed tomography (CT) angiogram to a perprocedurally acquired cone-beam CT or two fluoroscopic orthogonal projections. After registration, the 3D angiography images can be overlaid on the fluoroscopy screen and will follow table and C-arm movements. This study will assess the added value of the 3D image fusion technique in iliac artery interventions regarding the amount of the iodinated contrast agent administered. The study cohort will comprise 106 patients (> 18 years) with symptomatic common and/or external iliac artery stenoses or occlusions and a recent (< 6 months) diagnostic MRA from the pelvis through the lower extremities, for which an endovascular intervention is indicated. Patients will be randomized into the control or study group (i.e. treatment without or with 3D image fusion guidance). The primary endpoint is the amount of administered iodinated contrast agent (mL). Secondary outcomes are technical success of the procedure, defined as < 30% residual stenosis over the treated lesion, fluoroscopy time, and radiation dose as dose area product (mGycm2). Patient participation in the study will be completed after hospital discharge. This study is a randomized controlled multicenter trial to provide evidence on the effect of the 3D image fusion technique on the amount of administered iodinated contrast during endovascular common and/or external iliac artery interventions. Nederlands Trial Register, NTR5008 . Registered on 16 December 2014.
Purpose: To determine pulmonary arteriovenous malformation (PAVM) persistence and safety of high-volume detachable non-fibred (HVDNF) coil embolisation of de novo simple PAVMs using computed tomography pulmonary angiography (CTPA) at 6-month and 3-year follow-up. Methods: This retrospective single-cohort study included patients who underwent embolisation of de novo simple PAVMs, exclusively with HVDNF coils, between January 2018 and January 2021. Primary endpoints were PAVM persistence at 6 months, cumulative persistence at 3 years and coil recanalisation at 6 months and 3 years. Secondary endpoints were technical success, safety, repeat embolisation and vein diameter reduction. Persistence and recanalisation were confirmed with digital subtraction angiography (DSA). Results: This study included 50 patients with 75 de novo PAVMs. PAVM persistence at 6 months was 13.2%; cumulative persistence at 3 years was 17.4%. Coil recanalisation was the persistence mechanism in 10.3% of the cases at 6 months; at 3 years, this was 13.0%. Technical success rate was 98.7%. There were no procedure- or PAVM-related serious adverse events. Repeat embolisation with HVDNF coils was performed in 4 PAVMs after 6 months and 5 PAVMs after 3 years. Mean vein diameter reduction was 38.3% (SD 29.4%) at 6 months and 44.6% (SD 36.5%) at 3 years. Conclusions: HVDNF coils are safe to use for de novo PAVM embolisation, show an excellent technical success rate and are associated with acceptable 6-month and 3-year persistence and coil recanalisation rates.