Kuldeep Dixit

Mr. Kuldeep Dixit

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Sagnik DeySagnik Dey
Sagnik Dey
BPBhavesh Purohit
Bhavesh Purohit
PBPalak Balyan
Palak Balyan
KDKuldeep Dixit
Kuldeep Dixit
KBKunal Bali
Kunal Bali
VSV. K. Shukla
V. K. Shukla
Fine particulate matter (PM2.5) is a major criteria pollutant affecting the environment, health and climate. In India where ground-based measurements of PM2.5 is scarce, it is important to have a long-term database at a high spatial resolution for an efficient air quality management plan. Here we develop and present a high-resolution (1-km) ambient PM2.5 database spanning two decades (2000–2019) for India. We convert aerosol optical depth from Moderate Resolution Imaging Spectroradiometer (MODIS) retrieved by Multiangle Implementation of Atmospheric Correction (MAIAC) algorithm to surface PM2.5 using a dynamic scaling factor from Modern-Era Retrospective analysis for Research and Applications Version 2 (MERRA-2) data. The satellite-derived daily (24-h average) and annual PM2.5 show a R2 of 0.8 and 0.97 and root mean square error of 25.7 and 7.2 μg/m3, respectively against surface measurements from the Central Pollution Control Board India network. Population-weighted 20-year averaged PM2.5 over India is 57.3 μg/m3 (5–95 percentile ranges: 16.8–86.9) with a larger increase observed in the present decade (2010–2019) than in the previous decade (2000 to 2009). Poor air quality across the urban–rural transact suggests that this is a regional scale problem, a fact that is often neglected. The database is freely disseminated through a web portal ‘satellite-based application for air quality monitoring and management at a national scale’ (SAANS) for air quality management, epidemiological research and mass awareness.

4 January 2021 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
RAVI SAHURAVI SAHU
RAVI SAHU
ANAyush Nagal
Ayush Nagal
KDKuldeep Dixit
Kuldeep Dixit
HUHarshavardhan Unnibhavi
Harshavardhan Unnibhavi
SMSrikanth Mantravadi
Srikanth Mantravadi
STSachchida N Tripathi
Sachchida N Tripathi
Low-cost sensors offer an attractive solution to the challenge of establishing affordable and dense spatio-temporal air quality monitoring networks with greater mobility and lower maintenance costs. These low-cost sensors offer reasonably consistent measurements but require in-field calibration to improve agreement with regulatory instruments. In this paper, we report the results of a deployment and calibration study on a network of six air quality monitoring devices built using the Alphasense O3 (OX-B431) and NO2 (NO2-B43F) electrochemical gas sensors. The sensors were deployed in two phases over a period of 3 months at sites situated within two megacities with diverse geographical, meteorological and air quality parameters. A unique feature of our deployment is a swap-out experiment wherein three of these sensors were relocated to different sites in the two phases. This gives us a unique opportunity to study the effect of seasonal, as well as geographical, variations on calibration performance. We report an extensive study of more than a dozen parametric and non-parametric calibration algorithms. We propose a novel local non-parametric calibration algorithm based on metric learning that offers, across deployment sites and phases, an R2 coefficient of up to 0.923 with respect to reference values for O3 calibration and up to 0.819 for NO2 calibration. This represents a 4–20 percentage point increase in terms of R2 values offered by classical non-parametric methods. We also offer a critical analysis of the effect of various data preparation and model design choices on calibration performance. The key recommendations emerging out of this study include (1) incorporating ambient relative humidity and temperature into calibration models; (2) assessing the relative importance of various features with respect to the calibration task at hand, by using an appropriate feature-weighing or metric-learning technique; (3) using local calibration techniques such as k nearest neighbors (KNN); (4) performing temporal smoothing over raw time series data but being careful not to do so too aggressively; and (5) making all efforts to ensure that data with enough diversity are demonstrated in the calibration algorithm while training to ensure good generalization. These results offer insights into the strengths and limitations of these sensors and offer an encouraging opportunity to use them to supplement and densify compliance regulatory monitoring networks.

1 April 2025 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
ASAshutosh Shukla
Ashutosh Shukla
STSachchida N Tripathi
Sachchida N Tripathi
STShamitaksha Talukdar
Shamitaksha Talukdar
VMVishnu Murari
Vishnu Murari
SGSreenivas Gaddamidi
Sreenivas Gaddamidi
APAndré S. H. Prévôt
André S. H. Prévôt
High-time-resolution aerosol measurements across various Indo-Gangetic Plain (IGP) regions are critical due to these regions' dense populations, intense industrial activities, recurring pollution episodes, and agricultural practices, as well as the associated health impacts and broader climate implications of aerosol. However, studies (mostly offline) have been predominantly concentrated in the upper IGP (U-IGP), with limited spatial coverage across the central IGP (C-IGP). This study aims to bridge the gap by examining both U-IGP and C-IGP regions, offering an in-depth analysis of elemental concentrations, source apportionment, inter-regional comparisons, seasonal variations, meteorological influences, and health risks through high-resolution Xact measurements conducted at three urban locations. During the colder seasons, elements such as sulfur (S), chlorine (Cl), and potassium (K) were found to dominate elemental PM2.5 concentrations, while the warm seasons showed notable changes in aluminum (Al), silica (Si), strontium (Sr), and barium (Ba) concentrations. These variations underscore the influence of meteorological conditions and different emission sources on pollution levels. From a health perspective, average levels of carcinogenic elements (lead (Pb), nickel (Ni), arsenic (As), and chromium (Cr)) were usually kept below reference levels. However, Pb concentrations exceeded these thresholds by 40 %–50 % during both periods in the U-IGP, largely attributed to coal combustion and lead smelting activities. Using the Multilinear Engine 2 (ME-2) solver, positive matrix factorization (PMF) deconvolved Cl-rich, coal combustion, Cu-rich, dust, solid fuel combustion 1 (SFC1), SFC2, and S-rich components. In both IGP regions, Cl-rich sources, S-rich sources, and SFC1 dominated the elemental sources, with differences observed in their relative contributions, indicating the influence of regional emissions. The role of meteorology in elemental PM2.5 variations during both clean and polluted episodes in the IGP regions was observed. During pollution episodes, the relative contribution of Cl-rich sources increased when PM2.5 concentrations showed a sharp increase as compared to clean periods, especially during cold periods, indicating the role of emissions from trash burning (plastic and PVC) and steel industries along with favorable meteorological conditions in the formation and accumulation of pollutants. During the warm period, the relative contribution of Cl-rich sources in the C-IGP is less, but during the cold period, both the U-IGP and the C-IGP have significant Cl-rich source contributions (44 %), indicating the role of chlorine in extreme haze air pollution in the whole IGP region. During warm periods, high-pollution events occurred across the IGP with major contributions from SFC1 (crop residue burning), indicating that severe pollution events also depend on seasonal emission sources despite less favorable meteorological conditions. These findings provide valuable insights into the spatial and temporal dynamics of elemental pollution across the IGP, offering a robust foundation for devising targeted mitigation strategies and regulatory policies to safeguard public health in this densely populated region.

18 March 2025 in ACS Earth and Space Chemistry
Verified
Journal Article
Closed access
AKAlok Kumar
Alok Kumar
FIFahad Imam
Fahad Imam
KDKuldeep Dixit
Kuldeep Dixit
ECEkta Chaudhary
Ekta Chaudhary
SSSumit Sharma
Sumit Sharma
Sagnik DeySagnik Dey
Sagnik Dey

12 July 2024
Verified
Other
Open access
ASAshutosh Shukla
Ashutosh Shukla
STSachchida Nand Tripathi
Sachchida Nand Tripathi
STShamitaksha Talukdar
Shamitaksha Talukdar
VMVishnu Murari
Vishnu Murari
SGSreenivas Gaddamidi
Sreenivas Gaddamidi
APAndre Stephan Henry Prevot
Andre Stephan Henry Prevot

12 July 2024 in EGUsphere
Verified
Preprint
Open access
PDF file
ASAshutosh Shukla
Ashutosh Shukla
STSachchida N Tripathi
Sachchida N Tripathi
STShamitaksha Talukdar
Shamitaksha Talukdar
VMVishnu Murari
Vishnu Murari
SGSreenivas Gaddamidi
Sreenivas Gaddamidi
APAndre Stephan Henry Prevot
Andre Stephan Henry Prevot
High time-resolution aerosol measurements across various regions of the Indo-Gangetic Plain (IGP) are essential due to its dense population, intense industry, pollution episodes, agriculture, health impacts, and climate implications. However, absence of studies in Central IGP (C-IGP) limits the comprehensive understanding, as research has been primarily concentrated in Upper IGP (U-IGP) with limited spatial coverage. To address this gap, the study aimed to provide insights into elemental concentrations, sources, regional comparisons, seasonal variations, meteorological influences, and health risks using Xact at three urban sites in U-IGP and C-IGP regions. During cold, S, Cl, and K were major contributors to elemental-PM2.5, while warm periods exhibited significant variations in Al, Si, Sr, and Ba concentrations, indicating seasonal influences on pollution levels. Average concentrations of carcinogenic elements (Pb, Ni, As, and Cr) typically stayed below recommended levels, but individual exceedances of Pb was 40–50 % during both periods in U-IGP, linked to coal combustion and lead smelting. Positive Matrix Factorization (PMF) using ME-2 (Multilinear engine 2) solver was performed, resolving Cl-rich, coal combustion, Cu-rich, dust, SFC1 (Solid fuel combustion 1), SFC2, and S-rich. Cl-rich, S-rich, and SFC1 in both regions, with differences observed in their relative contributions, indicating the influence of regional emissions. Role of meteorology in variation of elemental-PM2.5 during clean and polluted episodes in IGP regions were observed. During pollution episodes, when PM2.5 concentrations showed sharp increase as compared to clean periods especially during cold, the relative contribution of Cl-rich increased which is due to the condensation of Chloride during low temperature, indicating the role of steel industries as well as trash (plastic and PVC (Polyvinyl chloride) mixed) in the pollution episode as well as haze formations. However, the clean periods during warm were dominated by Dust and S-rich. Overall, the study highlights the variation of elemental pollution across IGP regions, its health impact and factors driving the pollution episodes. These findings aid in understanding spatial and temporal dynamics of elemental pollution, informing mitigation strategies and policies for public health protection in the region.