We aimed to compare the performance of the C-MAC video laryngoscope (C-MAC) to the Macintosh laryngoscope for intubation of blunt trauma patients in the ED. This was a prospective randomized study. The primary outcome measure is overall successful intubation. Secondary outcome measures are first attempt successful intubation, Cormack-Lehane (CL) grade, and indicators of the reasons for unsuccessful intubation at the first attempt with each device. Adult patients who suffered from blunt trauma and required intubation were randomized to video laryngoscopy with C-MAC device or direct laryngoscopy (DL). During a 17-month period, a total of 150 trauma intubations were performed using a C-MAC and DL. Baseline characteristics of patients were similar between the C-MAC and DL group. Overall success for the C-MAC was 69/75 (92%, 95% CI 0.83 to 0.96) while for the DL it was 72/75 (96%, 95% CI 0.88 to 0.98). First attempt success for the C-MAC was 47/75 (62.7%, 95% CI 0.51 to 0.72) while for the DL it was 44/75 patients (58.7%, 95% CI 0.47 to 0.69). The mean time to achieve successful intubation was 33.4 ± 2.5 s for the C-MAC versus 42.4 ± 5.1 s for the DL (p = 0.93). There was a statistically significant difference between the DL and C-MAC in terms of visualizing the glottic opening and esophageal intubation in favor of the C-MAC (p = 0.002 and p = 0.013 respectively). The overall success rates were similar. The C-MAC demonstrated improved glottic view and decrease in esophageal intubation rate.
1 February 2016 in The American Journal of Emergency Medicine
We aimed to determine the value of sidestream end-tidal carbon dioxide (SS-ETCO2) measurement in patients with chronic obstructive pulmonary disease (COPD) in the emergency department. Cross-sectional associations between ETCO2 and PaCO2 were examined in the study. This prospective cross-sectional study has been carried out over a 3-month period in a tertiary care university hospital emergency department with an annual census of 75 000 visits. During the study period, simultaneous SS-ETCO2 measurement using a Medlab Cap 10 sidestream capnograph was performed on every COPD patient requiring arterial blood gas analysis. The demographics, diagnosis, vital signs, laboratory test results and clinical outcomes of the patients were recorded. SS-ETCO2 measurement and arterial blood gas analysis were carried out on 118 patients. Mean arterial PCO2 levels were 43.24±14.73 and mean ETCO2 levels were 34.23±10.86 mmHg. Agreement between PCO2 and ETCO2 measurements was 8.4 mmHg and a precision of 11.1 mmHg. As there is only a moderate correlation between PCO2 and ETCO2 levels in COPD patients, ETCO2 measurement should not be considered as a part of the decision-making process to predict PaCO2 level in COPD patients.
1 January 2010 in The American Journal of Emergency Medicine
Objective To determine if the serum levels of creatine kinase and myoglobin can be used to differentiate the grandmal tonic–clonic seizure and syncope activities in the emergency department (ED). Methods Consecutive patients over 16 years old who presented to an ED of a tertiary care hospital with a witnessed tonic–clonic seizure activity and a history of a transient loss of consciousness with normal neurological exams in the ED were selected to either seizure or syncope groups. Patients with an unclear history of seizure or syncope with more than 4 h of the activity and with any conditions that could elevate creatine kinase and myoglobin levels were excluded. Serum samples were drawn at presentation and at the fourth hour of the event. Results Thirty-seven syncope and 26 generalized tonic–clonic seizure patients with a definite history were assigned to study groups. There was not a statistically significant difference in the time of drawing of the first serum sample among groups. No statistically significant differences were determined with the first samples of creatine kinase and myoglobin for both groups. Serum levels of creatine kinase drawn at the fourth hour of the activity were significantly higher in favor of the seizure group. However, myoglobin levels were insignificant at the fourth hour. Conclusion Serum creatine kinase measured at the fourth hour of loss of consciousness may be a potentially useful laboratory test to differentiate tonic–clonic seizure from syncope. Patently, it requires and warrants further study.
1 June 2009 in The American Journal of Emergency Medicine