The measurements of proton–nucleus scattering and high resolution neutrino–nucleus interaction imaging are key in reducing neutrino oscillation systematic uncertainties in future experiments. A High Pressure Time Projection Chamber (HPTPC) prototype has been constructed and operated at the Royal Holloway University of London and CERN as a first step in the development of a HPTPC that is capable of performing these measurements as part of a future long-baseline neutrino oscillation experiment, such as the Deep Underground Neutrino Experiment. In this paper, we describe the design and operation of the prototype HPTPC with an argon based gas mixture. We report on the successful hybrid charge and optical readout using four CCD cameras of signals from sources.
This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g., , producing -emissions with energies ranging from 10 to several 100 when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance as a detector of X-rays and low energy -rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 to 60 are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2%. The Neo sCMOS is not sensitive to X-rays with energies below . The smallest detectable rate is , corresponding to an incident activity on the chip of . The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08(2)% (0.0011(2)%) at (). Taking calorimetric information into account we measure a minimal detectable rate of () for () -rays, which corresponds to an incident activity of (). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a - and X-ray detector with sensitivity at the few to 100 ppb level for in a sample.
This paper reports the design of a biosensor for sensitive, low-cost measurement of lead in drinking water. The biosensor uses a genetically-modified strain of Escherichia coli, which serves as both signal amplifier and reporter of lead in water, measured via colour change. We developed the PlomBOX measurement platform to image this colour change and we demonstrate its capability to detect concentrations as low as the World Health Organisation upper limit for drinking water of 10 ppb. Our approach does not require expensive infrastructure or expert operators, and its automated sensing, detection and result visualisation platform is user-friendly and robust compared to existing lead biosensors—critical features to enable measurement by non-experts at the point of use.
21 March 2025 in Monthly Notices of the Royal Astronomical Society
PSR B1828–11 is a radio pulsar that undergoes periodic modulations (∼500 d) of its spin-down rate and beamwidth, providing a valuable opportunity to understand the rotational dynamics of neutron stars. The periodic modulations have previously been attributed to planetary companion(s), precession, or magnetospheric effects and have several interesting features: they persist over 10 cycles, there are at least two harmonically related components, and the period is decreasing at a rate of about 5 d per cycle. PSR B1828–11 also experienced a glitch, a sudden increase in its rotation frequency, at $55040.9 \,{\rm MJD}$. By studying the interaction of the periodic modulations with the glitch, we seek to find evidence to distinguish explanations of the periodic modulation. Using a phenomenological model, we analyse a data set from Jodrell Bank Observatory, providing the longest and highest resolution measurements of the pulsar’s spin-down rate data. Our phenomenological model consists of step changes in the amplitude, modulation frequency, and phase of the long-term periodic modulation and the usual spin-down glitch behaviour. We find clear evidence with a (natural-log) Bayes factor of 1486 to support that not only is there a change to these three separate parameters but that the shifts occur before the glitch. We also present model-independent evidence which demonstrates visually how and when the modulation period and amplitude change. Discontinuities in the modulation period are difficult to explain if a planetary companion sources the periodic modulations, but we conclude with a discussion on the insights into precession and magnetospheric switching.
In their fourth observing run, the LIGO-Virgo-KAGRA gravitational-wave observatories have found hundreds of new signals, but many are contaminated by non-Gaussian transient noise artifacts known as glitches. Left unaddressed, glitches can bias parameter inference and lead to misleading astrophysical conclusions. We present a series of case studies using ilby, a parameter estimation tool that employs a time-domain likelihood jointly modeling the astrophysical signal with a physical waveform and non-Gaussian noise with a Gaussian process. We first show that when the detector noise is Gaussian, ilby produces results consistent with those obtained with the standard Gaussian-noise likelihood, and then consider events affected by non-Gaussian features. For GW231123, the highest-mass binary black hole candidate observed to date, analyses using reveal coherent residual structure that leads to measurable shifts in inferred source parameters. In contrast, analyses employing show no significant excess residual power and remain consistent across likelihood choices. This demonstrates that waveform systematics and flexible noise modeling are intrinsically coupled, as the Gaussian process terms can partially absorb coherent waveform mismatches. For GW191109, we find that evidence for spin misalignment remains robust despite glitches in both LIGO detectors. For GW230630_070659, excluded from GWTC-4.0 owing to poor data quality, we find the data to be consistent with a binary black hole waveform model, with no additional residual power identified by the Gaussian process component. Overall, these results highlight how ilby can be used to perform glitch-robust inference and as a tool to understand waveform modeling systematics.
The World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity range of low-cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 ( $${}^{210}$$ Pb), as a means to increase the solute’s concentration. $${}^{210}$$ Pb is a radioactive lead isotope and its concentration in a water sample can be measured with e.g. High Purity Germanium (HPGe) detectors at the Boulby Underground Germanium Suite. Concentrations close to the WHO limit have not been examined. This paper presents a measurement of the volume reduction technique retaining $$99\pm (9)$$ % of $${}^{210}$$ Pb starting from a concentration of $$1.9 \times 10^{-6}$$ ppb before reduction and resulting in $$2.63 \times 10^{-4}$$ ppb after reduction. This work also applies the volume reduction technique to London tap water and reports the radioassay results from gamma counting in HPGe detectors. Among other radio-isotopes, $${}^{40}$$ K, $${}^{210}$$ Pb, $${}^{131}$$ I and $${}^{177}$$ Lu were identified at measured concentrations of $$2.83 \times 10^{3}$$ ppb, $$2.55 \times 10^{-7}$$ ppb, $$5.06 \times 10^{-10}$$ ppb and $$5.84 \times 10^{-10}$$ ppb in the London tap water sample. This technique retained $${90 \pm 50}{\%}$$ of $${}^{40}$$ K. Stable lead was inferred from the same water sample at a measured concentration of 0.012 ppb, prior to reduction.
About Me
I am a Physics PhD student from Royal Holloway, University of London.
I am a Physics PhD student from Royal Holloway, University of London.