Ahmad Alzahrani

Dr. Ahmad Alzahrani

Electrical Engineering, Najran University, Najrān, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Procedia Computer Science
Verified
Journal Article
Open access
AAAhmad Alzahrani
Ahmad Alzahrani
PSPourya Shamsi
Pourya Shamsi
CDCihan Dagli
Cihan Dagli
MFMehdi Ferdowsi
Mehdi Ferdowsi

27 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
AAAhmad Alzahrani
Ahmad Alzahrani
Senthil Kumar RamuSenthil Kumar Ramu
Senthil Kumar Ramu
GDGunapriya Devarajan
Gunapriya Devarajan
IVIndragandhi Vairavasundaram
Indragandhi Vairavasundaram
Subramaniyaswamy VairavasundaramSubramaniyaswamy Vairavasundaram
Subramaniyaswamy Vairavasundaram
Hydrogen is acknowledged as a potential and appealing energy carrier for decarbonizing the sectors that contribute to global warming, such as power generation, industries, and transportation. Many people are interested in employing low-carbon sources of energy to produce hydrogen by using water electrolysis. Additionally, the intermittency of renewable energy supplies, such as wind and solar, makes electricity generation less predictable, potentially leading to power network incompatibilities. Hence, hydrogen generation and storage can offer a solution by enhancing system flexibility. Hydrogen saved as compressed gas could be turned back into energy or utilized as a feedstock for manufacturing, building heating, and automobile fuel. This work identified many hydrogen production strategies, storage methods, and energy management strategies in the hybrid microgrid (HMG). This paper discusses a case study of a HMG system that uses hydrogen as one of the main energy sources together with a solar panel and wind turbine (WT). The bidirectional AC-DC converter (BAC) is designed for HMGs to maintain power and voltage balance between the DC and AC grids. This study offers a control approach based on an analysis of the BAC’s main circuit that not only accomplishes the function of bidirectional power conversion, but also facilitates smooth renewable energy integration. While implementing the hydrogen-based HMG, the developed control technique reduces the reactive power in linear and non-linear (NL) loads by 90.3% and 89.4%.

1 January 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
AAAhmad Alzahrani
Ahmad Alzahrani
MFMehdi Ferdowsi
Mehdi Ferdowsi
PSPourya Shamsi
Pourya Shamsi

9 January 2019 in IEEE Access
Verified
Journal Article
Open access
AAAhmad Alzahrani
Ahmad Alzahrani
MFMehdi Ferdowsi
Mehdi Ferdowsi
PSPourya Shamsi
Pourya Shamsi

3 February 2023 in Applied Energy
Verified
Journal Article
Closed access
AAAhmad Alzahrani
Ahmad Alzahrani
KSKhizar Sajjad
Khizar Sajjad
Ghulam HafeezGhulam Hafeez
Ghulam Hafeez
SMSadia Murawwat
Sadia Murawwat
SKSheraz Khan
Sheraz Khan
AKAftab Aslam Parwaz Khan
Aftab Aslam Parwaz Khan

29 March 2023 in IEEE Access
Verified
Journal Article
Open access
AAAhmad Alzahrani
Ahmad Alzahrani
MRMujeeb Ur Rahman
Mujeeb Ur Rahman
Ghulam HafeezGhulam Hafeez
Ghulam Hafeez
GRGul Rukh
Gul Rukh
SASajjad Ali
Sajjad Ali
AAAzher M. Abed
Azher M. Abed
Multi-objective energy optimization is pivotal for reliable and secure power system operation. However, multi-objective energy optimization is challenging due to interdependent and conflicting objectives. Thus, a multi-objective optimization model is needed to cater to conflicting objectives. On this note, a multi-objective optimization model is developed, where a non-dominated genetic sorting algorithm is employed to optimize objectives pollution emission, operation cost, and loss of load expectation (LOLE) considering renewable energy sources (RES). RES, like wind and solar, are intermittent and uncertain, which are modelled using a beta probability density function (PDF). The developed method’s effectiveness and applicability are analyzed by implementing it on the 30-bus system, and the results are compared for two cases. Findings reveal that the developed multi-objective optimization model minimizes operation cost, pollution emission, and LOLE by 59%, 7%, and 2.67%, respectively, compared to existing models.