Ja-Yu Lu

Prof. Ja-Yu Lu

Department of Photonics, National Cheng Kung University, Tainan City 701, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2008 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
TLTzu-Ming Liu
Tzu-Ming Liu
JLJa-Yu Lu
Ja-Yu Lu
HCHung-Ping Chen
Hung-Ping Chen
CKChung-Chiu Kuo
Chung-Chiu Kuo
MYMeng-Ju Yang
Meng-Ju Yang
CSChi-Kuang Sun
Chi-Kuang Sun
Taking advantage of the specific core-shell charge separation structure in the CdSe∕CdTe core-shell type-II nanocrystals, we experimentally observed and verified the existence of the resonance-enhanced dipolar interaction between terahertz photons and their corresponding confined acoustic phonons. From the measured terahertz transmission spectra, we found that the photon frequency of the terahertz resonant absorption is inversely proportional to the diameter D of the nanocrystals and agrees with that of dipolar active l=1 , n=0 confined acoustic modes. The corresponding absorption cross section shows a D4 dependence, supporting a charged simple-harmonic-oscillator model. These facts verify the occurrence of dipolar interaction between terahertz photons and confined terahertz acoustic phonons.

3 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JLJa-Yu Lu
Ja-Yu Lu
Borwen YouBorwen You
Borwen You
JWJiun-You Wang
Jiun-You Wang
SJSheng-Syong Jhuo
Sheng-Syong Jhuo
THTun-Yao Hung
Tun-Yao Hung
CYChin-Ping Yu
Chin-Ping Yu
Gas sensing to recognize volatile liquids is successfully conducted through pipe-guided terahertz (THz) radiation in a reflective and label-free manner. The hollow core of a pipe waveguide can efficiently deliver the sensing probe of the THz confined waveguide fields to any place where dangerous vapors exist. Target vapors that naturally diffuse from a sample site into the pipe core can be detected based on strong interaction between the probe and analyte. The power variation of the THz reflectance spectrum in response to various types and densities of vapors are characterized experimentally using a glass pipe. The most sensitive THz frequency of the pipe waveguide can recognize vapors with a resolution at a low part-per-million level. The investigation found that the sensitivity of the pipe-waveguide sensing scheme is dependent on the vapor absorption strength, which is strongly related to the molecular amount and properties including the dipole moment and mass of a gas molecule.

23 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
JLJa-Yu Lu
Ja-Yu Lu
PCPo-Lun Chen
Po-Lun Chen
Borwen YouBorwen You
Borwen You
Terahertz (THz) spectroscopy has been proven as an effective detection means for the label-free and nondestructive sensing of biochemical molecules based on their unique roto-vibrational transitions. However, the conventional THz spectroscopic system is unsuitable for minute material sensing due to its far-field detection scheme, low sample amount, and lack of spectral characteristics, leading to low absorption cross-sections and sensitivity. In this study, a 3D plasmonic structure based on a metal-coated woven-wire mesh (MCWM) was experimentally and numerically demonstrated for sensing trace amounts of analytes combined with THz spectroscopy. Dual sharp spectral features were exhibited in the transmission spectrum, originating from the resonant excitation of THz surface electromagnetic modes via the aperture and periodicity of the MCWM unit cell. According to the finite element simulation, an enhanced and localized surface field was formed at THz resonant frequencies and was concentrated at the metal gaps near the periodic corrugations of the MCWM, resulting in enormous resonant dip shifts caused by the tiny variations in membrane thicknesses and refractive indices. Different types and quantities of analytes, including hydrophilic biopolymer (PAA) membrane, nonuniformly distributed microparticles to mimic macro-biomolecules or cells, and electrolyte salts of PBS, were successfully identified by the MCWM sensor with the best thickness and refractive index sensitivities approaching 8.26 GHz/μm and 547 GHz/RIU, respectively. The demonstrated detection limit of thickness and molecular concentration could respectively achieve nanometer and femtomolar scales in PAA macromolecular detection, surpassing the available metallic mesh devices. The MCWM-based sensing platform presents a rapid, inexpensive, and simple analysis method, potentially paving the way for a new generation of label-free microanalysis sensors.

4 August 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Borwen YouBorwen You
Borwen You
Chih-Feng HuangChih-Feng Huang
Chih-Feng Huang
JLJa-Yu Lu
Ja-Yu Lu
A simple and compact intensity-interrogated terahertz (THz) relative humidity (RH) sensing platform is successfully demonstrated in experiments on the basis of combining a porous polymer sensing membrane and a continuous THz electronic system. The RH-sensing membrane is fabricated by surface modification of a porous polymer substrate with hydrophilic and photosensitive copolymer brushes via a UV-induced graft-polymerization process. The intensity interrogation sensing scheme indicated that the power reduction of the 0.4 THz wave is dependent on the grafting density of the copolymer brushes and proportional to the RH percent levels in the humidity-controlled air-sealed chamber. This finding was verified by the water contact angle measurement. Based on the slope of the proportional relation, the best sensitivity of the hydrophilic surface-modified sensing membrane was demonstrated at 0.0423 mV/% RH at the copolymer brush density of 1.57 mg/mm3 grafted on the single side of the sensing membrane. The sensitivity corresponds to a detection limit of approximately 1% RH. The THz RH sensing membrane was proven to exhibit the advantages of low loss, low cost, flexibility, high sensitivity, high RH resolution, and a wide RH working range of 25–99%. Thus, it is a good candidate for novel applications of wearable electronics, water- or moisture-related industrial and bio-sensing.

2 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
Borwen YouBorwen You
Borwen You
JLJa-Yu Lu
Ja-Yu Lu
PCPo-Lun Chen
Po-Lun Chen
THTun-Yao Hung
Tun-Yao Hung
CYChin-Ping Yu
Chin-Ping Yu
Metal-hole-supported terahertz (THz) waves through the structure of a metal-wire-woven hole array (MWW-HA) present high-frequency-passed transmittance spectra of one plasmonic metamaterial with artificial plasmonic frequencies, which are inversely proportional to metal-hole widths. For the transmitted THz waves of MWW-HA, transverse-electric (TE) and transverse-magnetic (TM) waveguide modes mix within a symmetric metal-hole boundary. THz resonance waves transversely crossing the holes of MWW-HA are experimentally characterized with spectral peaks in the frequency range of 0.1–2 THz that are correlated with aperture sizes, unit-cell-hole widths, metal-wire thicknesses, and wire-bending angles. The metal-hole-transported resonance waves of MWW-HA are dominated by TE waveguide modes instead of TM ones because a hole width of MWW-HA is approximate to the half wavelength of a resonance wave. The round metal edges of the woven metal wires can minimize the effective optical length of a thick metal hole to transmit THz resonance waves, thereby resulting the smallest rotation angle of linear polarization and high transmittance up to 0.94. An MWW-HA structure is therefore reliable for supporting metal-hole resonance waves with low resistance, whereas a metal-slab-perforated hole array cannot achieve the same result.

10 December 2023 in Results in Physics
Verified
Journal Article
Open access
JLJa-Yu Lu
Ja-Yu Lu
CCChien-Yu Chen
Chien-Yu Chen
BYBorwen You
Borwen You