Feifei Wang

Prof. Feifei Wang

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2011 in Science China Technological Sciences
Verified
Journal Article
Closed access
PDF file
Pengfei LiPengfei Li
Pengfei Li
JMJianchun Mi
Jianchun Mi
BDBassam Dally
Bassam Dally
FWFeifei Wang
Feifei Wang
LWLin Wang
Lin Wang
CZChuGuang Zheng
ChuGuang Zheng

1 August 2018 in Energy
Verified
Journal Article
Closed access
FWFeifei Wang
Feifei Wang
PLPengfei Li
Pengfei Li
JMJianchun Mi
Jianchun Mi
JWJinbo Wang
Jinbo Wang

1 April 2018 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
XJXudong Jiang
Xudong Jiang
PLPengfei Li
Pengfei Li
JGJunjun Guo
Junjun Guo
FHFan Hu
Fan Hu
FWFeifei Wang
Feifei Wang
ZLZhaohui Liu
Zhaohui Liu

17 February 2021 in Environmental Research
Verified
Journal Article
Closed access
CJChen Jiaxin
Chen Jiaxin
HHHui Hu
Hui Hu
FWFeifei Wang
Feifei Wang
ZMZhang Mi
Zhang Mi
ZTZhou Ting
Zhou Ting
HHHuang Hao
Huang Hao

1 July 2020 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
MWMinghao Wang
Minghao Wang
PLPengfei Li
Pengfei Li
FWFeifei Wang
Feifei Wang

10 October 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Chong ZhangChong Zhang
Chong Zhang
JWJinbo Wang
Jinbo Wang
LLLiao Li
Liao Li
FWFeifei Wang
Feifei Wang
WGWenjie Gang
Wenjie Gang
An earth-to-air heat exchanger (EAHE) system utilizes the low-grade thermal energy of underground soil to warm up and cool down the flowing air within an underground buried pipe. Integrating the EAHE system with building ventilation can reduce the energy demand for conditioning ventilation air. The main purposes of this paper are to estimate the year-round energy-saving potential of the EAHE-assisted building ventilation system and provide its design guidelines in a hot-summer and cold-winter climate. A steady-state heat transfer model was proposed to calculate the outlet air temperature of an EAHE and further identify its ability to preheat and precool ventilation air. Influences of depth, length, and diameter of a buried pipe on the year-round thermal performance of the EAHE system were evaluated. The results show that considering the compromise between thermal performance and construction costs of the EAHE system, a depth of 5 m and a length of 80 m are recommended. The EAHE system can provide a mean daily cooling and heating capacity of 19.6 kWh and 19.3 kWh, respectively. Moreover, the utilization of the EAHE system can reduce by 16.0% and 50.1% the energy demand for cooling and heating ventilation air throughout the whole year.