Flanagan Flanagan

Dr. Flanagan Flanagan

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2005 in Implant Dentistry
Verified
Journal Article
Closed access
Flanagan FlanaganFlanagan Flanagan
Flanagan Flanagan
There are 3 arteries that supply the maxillary sinus (i.e., the posterior superior alveolar, infraorbital, and posterior lateral nasal arteries), any of which may be encountered during lateral approach sinus elevation surgery. These arteries are ultimate branches of the maxillary artery. Although it has not been reported, there is a theoretical potential for severing an intraosseously located artery during a vigorous cur-ettage for sinus lining elevation in the posterior medial wall of the sinus. Techniques for cessation of bleeding are discussed, such as electrocautery and endoscopic ligation. Head elevation can significantly decrease blood flow to the area.

1 June 2017 in Medical Devices: Evidence and Research
Verified
Journal Article
Open access
PDF file
Flanagan FlanaganFlanagan Flanagan
Flanagan Flanagan
Dental implants are placed endosseously, and the bone is the ultimate bearer of the occlusal load. Patients are not uniform in the maximum bite force they can generate. The occlusal biting load in the posterior jaw is usually about three times of that found in the anterior. It is possible for supporting implants to be overloaded by the patients’ biting force, resulting in bone loss and failure of the fixture. Bite force measurement may be an important parameter when planning dental implant treatment. Some patients can generate extreme biting loads that may cause a luxation of the fixture and subsequent loss of osseointegration. A patient with low biting force may be able to have a successful long-term outcome even with poor anatomical bone qualities. Patients with a high bite force capability may have an increased risk for late component fracture or implant failure. There is no correlation of any bite force value that would indicate any overload of a given implant in a given osseous site. Nonetheless, after bite force measurement, a qualitative judgement may be made by the clinician for the selection of an implant diameter and length and prosthetic design.

1 April 2011 in Journal of Oral Implantology
Verified
Journal Article
Closed access
Flanagan FlanaganFlanagan Flanagan
Flanagan Flanagan
Andrea Felice MascoloAndrea Felice Mascolo
Andrea Felice Mascolo
Dental implant treatment can restore oral function to edentulous patients. Recently, mini implants have been shown to be successful in minimally invasive treatment. There are initial reports of mini implants retaining removable prostheses and supporting fixed partial and complete dentures. This article reviews the treatment of edentulous patients with prostheses and mini implants and offers guidelines for successful outcomes.

1 June 2008 in Implant Dentistry
Verified
Journal Article
Closed access
Flanagan FlanaganFlanagan Flanagan
Flanagan Flanagan
Very small diameter (1.8-3.3 mm) dental implants may be successfully used to support fixed partial dentures in edentulous sites of compromised bone width or length. Very small implants can be successfully used in highly selected sites where there is adequate bone density and bone volume for immediate implant stability. Adequate or augmentable attached gingiva may be a requirement. A small diameter implant presents less of an obstacle for angiogenesis and there is less percutaneous exposure and bone displacement as compared with standard sized implants. In posterior sites, rounded and narrow prosthetic teeth present small occlusal tables to minimize axial and off-axial directed forces. Multiple splinted implants may be necessary to minimize metal fatigue from cyclic loading. Anterior restorations supported by mini implants may need occlusal relief to minimize the effects of cyclic loading.

1 February 2017 in Journal of Oral Implantology
Verified
Journal Article
Closed access
Flanagan FlanaganFlanagan Flanagan
Flanagan Flanagan
Enterococcus faecalis appears in many tooth root infections and is not eliminated by root canal therapy. It can reside in tooth root canals and the surrounding bone. This species may vegetate in bone after extraction of an infected tooth and colonize a dental implant after placement in the healed site. A colonization may cause fixture loss or marginal bone loss. These colonizations are generally multibacterial and pathogenic properties can be shared via plasmids. However, E faecalis is not detectable with some culture techniques and thus can be missed. It is usually not a dominant species in these infections. Nonetheless, E faecalis may be a “keystone” player in dental implant bone loss or peri-implantitis. That is, E faecalis may be the pathogenic determinant for any particular peri-implantitis infection of a multiple-species infection.

1 June 2010 in Implant Dentistry
Verified
Journal Article
Closed access
Flanagan FlanaganFlanagan Flanagan
Flanagan Flanagan
Surgical placement of dental implants requires an osteotomy. There is suspicion that osseous drilling may generate detrimental heat in the site that may cause localized bone necrosis and, subsequently, failure of the dental implant to osseointegrate. Cooling aqueous irrigation has been advocated to prevent such overheating. However, irrigation can interfere with operator vision and precludes bone shaving collection from the drill flukes for use in autogenous grafting. Small diameter drills may generate more heat than larger diameter drills and may need to be irrigated when smaller diameter implants are to be placed in dense bone. Contemporary larger diameter drills may not generate detrimental heat and may incrementally remove any heat damaged bone from the previous drilling. It may be safe not to use irrigation for less bone dense sites when larger diameter drills are used. In addition, higher drill force and speed may minimize osseous heating by minimizing the time of in-bone drill operation and heat generation. Irrigation to prevent bone heating during the osteotomy may not be necessary when using contemporary drill designs with an expeditious drilling technique.