Kentaro Takagi

Prof. Kentaro Takagi

Toyohashi University of Technology
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2013 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
ZZZicai Zhu
Zicai Zhu
KAKinji Asaka
Kinji Asaka
LCLongfei Chang
Longfei Chang
KTKentaro Takagi
Kentaro Takagi
HCHualing Chen
Hualing Chen
Water-based ionic polymer–metal composites (IPMCs) exhibit complex deformation properties, especially with decreasing water content. Based on our experimental understanding, we developed a systemic actuation mechanism for IPMCs in which the water swelling was taken as the basic cause of deformation. We focused on Nafion-IPMC, and formulated a multiphysical model to describe the complicated deformation properties. The model emphasizes pressure-induced convection fluxes and the significance of the water distribution on deformation. It shows that there are three eigen stresses activated by the migration of ions and water, namely, osmotic pressure, electrostatic stress, and capillary pressure. The model also provides a convenient way of simultaneously handling the internal eigen stresses and the external mechanical load. In this paper, we used a fundamental model, which only considered the hydrostatic pressure in the multiphysical model, to analyze the general transport properties of cations and water by numerical methods. Three effects were investigated: (1) the inter-coupling effects between cations and water, which slow down cation migration and attenuate the back-diffusion of water; (2) the pressure effect, which rarely influences the electric field and the cation distribution, but greatly changes the profile of the water concentration and then the deformation behavior; and (3) the hydration effect, which has a significant impact on the distribution profiles of the cations and the electrical potential. In contrast to the findings of traditional studies, the water concentration displays an almost uniform gradient across the thickness in the bulk, and the cation concentration at the cathode is greatly reduced by the volume effect of the hydrated cations.

1 October 2006
Verified
Conference Paper
Closed access
KTKentaro Takagi
Kentaro Takagi
MYMasanori Yamamura
Masanori Yamamura
ZLZhi-Wei Luo
Zhi-Wei Luo
MOMasaki Onishi
Masaki Onishi
SHShinya Hirano
Shinya Hirano
YHYoshikazu Hayakawa
Yoshikazu Hayakawa
Ionic polymer-metal composite (IPMC), which is one of the electro-active polymer actuators, is expected as artificial muscles for robots. An interesting property of IPMC is that it requires water to work, therefore it is suitable for underwater robots. In this paper, we developed an underwater robot which mimics rajiform swimming, that is the swimming form of a ray fish. Fins are designed using sixteen IPMCs. For autonomous operation, miniaturization of the electrical devices such as a micro controllers and small amplifiers are performed. A simple traveling wave control input is employed to generate moment on the fin. In the experiment, propulsion speed is measured under various control parameters. Furthermore, incremental wave of the fin is observed although the amplitude of the control input is spatially uniform. We also discuss this phenomenon from the point of view of interaction between elasticity of the actuator and fluid dynamics

1 April 2011 in Control Engineering Practice
Verified
Journal Article
Closed access
GNGou Nishida
Gou Nishida
KTKentaro Takagi
Kentaro Takagi
BMBernhard Maschke
Bernhard Maschke
TOTakaaki Osada
Takaaki Osada

22 March 2016 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
ZZZicai Zhu
Zicai Zhu
LCLongfei Chang
Longfei Chang
THTetsuya Horiuchi
Tetsuya Horiuchi
KTKentaro Takagi
Kentaro Takagi
AAAlvo Aabloo
Alvo Aabloo
KAKinji Asaka
Kinji Asaka
Ion-migration based electrical potential widely exists not only in natural systems but also in ionic polymer materials. We presented a multi-physical model and investigated the transport process of cation and water of ionic polymer-metal composites based on our thorough understanding on the ionic sensing mechanisms in this paper. The whole transport process was depicted by transport equations concerning convection flux under the total pressure gradient, electrical migration by the built-in electrical field, and the inter-coupling effect between cation and water. With numerical analysis, the influence of critical material parameters, the elastic modulus Ewet, the hydraulic permeability coefficient K, the diffusion coefficient of cation dII and water dWW, and the drag coefficient of water ndW, on the distribution of cation and water was investigated. It was obtained how these parameters correlate to the voltage characteristics (both magnitude and response speed) under a step bending. Additionally, it was found that the effective relative dielectric constant εr has little influence on the voltage but is positively correlated to the current. With a series of optimized parameters, the predicted voltage agreed with the experimental results well, which validated our model. Based on our physical model, it was suggested that an ionic polymer sensor can benefit from a higher modulus Ewet, a higher coefficient K and a lower coefficient dII, and a higher constant εr.

4 August 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
ZZZicai Zhu
Zicai Zhu
LCLongfei Chang
Longfei Chang
KTKentaro Takagi
Kentaro Takagi
YWYanjie Wang
Yanjie Wang
HCHualing Chen
Hualing Chen
DLDichen Li
Dichen Li
Water-based ionic polymer–metal composites (IPMCs) exhibit an anode deformation followed by a back-relaxation deformation under a direct current voltage. The latter is strongly related to the water content. This Letter proposes an evaluation method of the critical water content for relaxation deformation. Based on Nafion-IPMC doped with various alkali cations, continuous deformations are measured under a periodic pulse voltage in air. A transformation of the relaxation deformation is found to exist between two successive pulses. The critical water content is confined between the two pulses and evaluated gravimetrically. Removal of no more than 4 wt. % water or 1.4–2 water molecules per cation from the saturated material can completely eliminate the large relaxation deformation in Nafion-IPMC doped with alkali cations.

28 August 2016 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
ZZZicai Zhu
Zicai Zhu
THTetsuya Horiuchi
Tetsuya Horiuchi
KTKentaro Takagi
Kentaro Takagi
JTJun Takeda
Jun Takeda
LCLongfei Chang
Longfei Chang
KAKinji Asaka
Kinji Asaka
In this study, we investigated the effects of various cations on the electrical responses of ionic polymer–metal composite (IPMC) sensors at various ambient humidities. Four typical Au–Nafion IPMC samples were prepared with H+, Li+, Na+, and K+ cations. The voltage and current responses of the IPMCs were investigated under static and dynamic bending displacements. The orders of the voltage and current amplitudes were generally Li+ > Na+ > K+ > H+ and depended on the cation transport properties and the water content. The static voltage response first increased to a peak and then slowly decreased to a steady state. A negative steady-state voltage was initially observed for the IPMC with H+ cations under near saturation conditions. The voltage amplitude increased monotonously with increasing frequency from 0.1 to 10 Hz at a high relative humidity (RH, ∼90%), first increased and then decreased at moderate humidity (RH, ∼50%), and decreased continuously at low humidity (RH, ∼20%). The static current response first rapidly increased to a peak and then quickly decayed. During current decay, free oscillation decay occurred at high humidity and attenuated with decreasing humidity. This was confirmed to be the result of cation movement in the IPMC. There are three necessary conditions for oscillation: sufficient migrated cations, high cation mobility, and high stiffness of the polymer network. For the dynamic current response, the amplitude increased with increasing frequency (0.1–10 Hz) and showed good linearity. The underlying physics, mainly involving cation forward migration and back diffusion caused by mechano-chemo-electrical coupling, was clarified.