Paul Fazio

Paul Fazio


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 1997 in Journal of Architectural Engineering
Verified
Journal Article
Closed access
PFPaul Fazio
Paul Fazio
AAAndreas K. Athienitis
Andreas K. Athienitis
CMCedric Marsh
Cedric Marsh
JRJiwu Rao
Jiwu Rao
This paper describes the design and development of an environmental chamber for investigation of building envelope performance as a function of heat, air, and moisture transfer, and the interaction between the building envelope and the indoor environment. The environmental chamber is the first of its kind in Canada and is unique in concept. It is located in a specially constructed laboratory of the Centre for Building Studies (CBS), in downtown Montreal. Experiments can be performed on envelope assemblies up to 7.2 m high and 4.1 m wide. The environmental chamber consists of two chambers representing dynamic indoor and outdoor conditions, denoted as hot and cold boxes, respectively. Between the hot and cold boxes, a rectangular frame is sandwiched, in which building envelope components can be built up. A metering box is also located on the hot box side of the test specimen to measure heat flow and temperature drop across it for thermal resistance measurement based on the guarded hot box method. Without the metering chamber, the facility can be used for tests similar to the calibrated hot box method. The second major function of the facility is its use as one large environmental chamber for testing full rooms.

31 December 2008 in Building and Environment
Verified
Journal Article
Closed access
AAArslan Alturkistani
Arslan Alturkistani
PFPaul Fazio
Paul Fazio
JRJiwu Rao
Jiwu Rao
QMQian Mao
Qian Mao

1 December 2007 in Journal of Architectural Engineering
Verified
Journal Article
Closed access
PFPaul Fazio
Paul Fazio
QMQian Mao
Qian Mao
Hua GeHua Ge
Hua Ge
AAArslan Alturkistani
Arslan Alturkistani
JRJiwu Rao
Jiwu Rao
Rainwater penetration is the source of moisture that causes the greatest damage to building envelope assemblies. The building envelope should be designed to reduce the amount of rainwater penetration by deflection and drainage. Since it is not realistic to assume a perfect wall without any leakage, the envelope should have the drying capacity to tolerate defects that may arise from the design, construction, and aging of the exterior wall system. Systems with a greater capacity to evacuate moisture from the stud cavity are less likely to undergo moisture damage. A new testing method is developed and deployed to evaluate the relative drying capacity of six wood-framed wall panels of different configurations built into a test hut and tested within a large scale environmental chamber. The wall panels used plywood, oriented strand board (OSB), or fiberboard as sheathing, but did not include cladding. A uniform moisture source was introduced in a water tray set on a load cell at the bottom of each stud cavity. The protocol is based on the hypothesis that the potential for moving a water molecule from the bottom plate to the exterior of the stud cavity is independent of the previous journey of that molecule, i.e., whether it has traveled from the interior of the bottom plate to the surface of the plate or whether it comes from free water in a tray at the level of the bottom plate. For a given set of boundary conditions, this potential is a function of the characteristics of the wall panel, and is identified as the drying capacity of the panel or its drying by evaporation index (DEI). The value of DEI corresponds to the evaporation rate. The moisture response of wall materials enclosing the stud cavity and the evaporation rate of the moisture source were monitored. The results show that this index can be used as an indicator of the relative drying capacity of different wall systems.

31 August 2009 in Building and Environment
Verified
Journal Article
Closed access
CHCaroline Hachem-Vermette
Caroline Hachem-Vermette
PFPaul Fazio
Paul Fazio
JRJiwu Rao
Jiwu Rao
KBKaren Bartlett
Karen Bartlett
YCYogendra P. Chaubey
Yogendra P. Chaubey

23 July 2007
Verified
Conference Paper
Closed access
XTXiangyang Tan
Xiangyang Tan
AHAmin Hammad
Amin Hammad
PFPaul Fazio
Paul Fazio
The need to satisfy many functional requirements makes building envelope performance assessment difficult. Furthermore, complexity and diversity of building regulations make the understanding of building codes and regulations a complicated task. This paper presents a method for automatically checking building code compliance according to the simulation results of building envelope performance. Firstly, building codes or regulations are represented as a knowledge base using decision tables in XML (Extensible Markup Language). Then, building envelope information is extracted from an IFC (Industry Foundation Classes) digital building model. Simulation programs are used to simulate the functional performance of building envelopes under variable exterior conditions. Finally, a prototype system HAMBE (Heat, Air and Moisture performance of Building Envelope) is developed for automated building code compliance checking. With the aid of this application, the automated building code compliance checking can help architects, engineers and other users query building codes and regulations quickly and efficiently.

31 August 2009 in Building and Environment
Verified
Journal Article
Closed access
JRJiwu Rao
Jiwu Rao
PFPaul Fazio
Paul Fazio
KBKaren Bartlett
Karen Bartlett
DYDian-Qing Yang
Dian-Qing Yang