Particulate matter (PM) less than 2.5 micron (PM 2.5 ) issue is 1 of the important targets of concern by the United Nations’ Sustainable Development Goals. Bangkok is a megacity and facing air pollution problems. This study analyzed PM, PM 2.5 and PM less than 10 micron (PM 10 ), monitoring data from stations located in Bangkok, and aimed to present their variations in diurnal, weekly, and intra-annual timescales. High PM concentrations are related to calm wind. The diurnal variation of PM 2.5 /PM 10 suggested a greater accumulation of PM 2.5 than PMcoarse during the low wind speed. Potential source areas affecting PM rising at each monitoring station were identified using statistical technique, bivariate polar plot, and conditional bivariate probability function. Results showed that Ratchathewi District Monitoring Station identified 3 potential source areas related to emissions from transportation sources creating rising PM concentrations. The first potential source was located in the northwest direction, namely, the Rama VI Road close to the conjunction with Ratchawithi Road. The second potential source area was located around the cross-section between Phaya Thai Road and Rama I Road, while the third was located at the intersection of the Phaya Thai Road to Yothi Street and Rang Nam Road. These potential source areas constitute useful information for managing and reducing PM.
16 October 2020 in Biomass Conversion and Biorefinery
Particulate matter less than 2.5 μm in diameter (PM2.5) pollution has gained more concern, as can be seen from the World Health Organization (WHO) revised air quality guideline (AQG) value. To compare with the 24-h AQG value, the 24-h mean (daily average) of hourly monitoring data has been widely used, but the nature of data in hourly variation has been lost. The 24-h moving average can be an alternative approach to preserving hourly data behavior, while various positions of the hour (leftmost, center, or rightmost hour) can be used to store the moving average. In this study, similarity testing by cross-correlation and Euclidean distance was performed to present a suitable 24-h moving average time series for hourly data, and then presented proportions of PM2.5 concentrations within each interim target and AQG ranges. The PM2.5 time series of the leftmost and rightmost 24-h moving average revealed lags of − 13 to − 10 h and 10 to 13 h for the observed hourly data, respectively. The lags of the center 24-h moving average time series were of − 2 to 1 h, which showed more similar events to the hourly PM2.5 fluctuation than the leftmost and rightmost time series. The center 24-h moving average concentrations measured in Bangkok were categorized into interim target and AQG ranges. The results revealed that the proportion of concentrations lower than AQG during nighttime and daytime was approximately 40 and 28%, respectively. However, the results given from the leftmost and rightmost time series showed time shifts and differences in diurnal variation caused by the position used to store the average value. To keep hourly PM2.5 variation that can be compared with the 24-h WHO guidelines, this should be performed with careful and precautionary consideration of misinterpretation over a time scale, especially for implementing countermeasures and policies.
12 August 2020 in Environmental Engineering Research