Marie Allen

Prof. Marie Allen

Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2022 in Genes
Verified
Journal Article
Open access
PDF file
MNMartina Nilsson
Martina Nilsson
HMHanne De Maeyer
Hanne De Maeyer
MAMarie Allen
Marie Allen
Decontamination strategies and their efficiencies are crucial when performing routine forensic analysis, and many factors influence the choice of agent to use. In this study, the effects of ten different cleaning strategies were evaluated to compare their ability to remove contaminating DNA molecules. Cell-free DNA or blood was deposited on three surfaces (plastic, metal, and wood) and decontaminated with various treatments. The quantities of recovered DNA, obtained by swabbing the surfaces after cleaning using the different strategies, was analyzed by real-time PCR. Large differences in the DNA removal efficiencies were observed between different cleaning strategies, as well as between different surfaces. The most efficient cleaning strategies for cell-free DNA were the different sodium hypochlorite solutions and Trigene®, for which a maximum of 0.3% DNA was recovered on all three surfaces. For blood, a maximum of 0.8% of the deposited DNA was recovered after using Virkon® for decontamination. The recoveries after using these cleaning strategies correspond to DNA from only a few cells, out of 60 ng of cell-free DNA or thousands of deposited blood cells.

1 September 2019 in Forensic Science International: Genetics
Verified
Journal Article
Closed access
MBMagdalena M. Buś
Magdalena M. Buś
MLMaria Lembring
Maria Lembring
AKAnna Kjellström
Anna Kjellström
CSChristina Strobl
Christina Strobl
BZBettina Zimmermann
Bettina Zimmermann
MAMarie Allen
Marie Allen

1 September 2016 in Forensic Science International: Genetics
Verified
Journal Article
Closed access
MNMartina Nilsson
Martina Nilsson
JGJoakim Grånemo
Joakim Grånemo
MBMagdalena M. Buś
Magdalena M. Buś
MHMikael Havsjö
Mikael Havsjö
MAMarie Allen
Marie Allen


Verified
Journal Article
Open access
PDF file
KSKimberly Sturk-Andreaggi
Kimberly Sturk-Andreaggi
JRJoseph D. Ring
Joseph D. Ring
Adam AmeurAdam Ameur
Adam Ameur
UGUlf Gyllensten
Ulf Gyllensten
MBMartin Bodner
Martin Bodner
MAMarie Allen
Marie Allen
Whole-genome sequencing (WGS) data present a readily available resource for mitochondrial genome (mitogenome) haplotypes that can be utilized for genetics research including population studies. However, the reconstruction of the mitogenome is complicated by nuclear mitochondrial DNA (mtDNA) segments (NUMTs) that co-align with the mtDNA sequences and mimic authentic heteroplasmy. Two minimum variant detection thresholds, 5% and 10%, were assessed for the ability to produce authentic mitogenome haplotypes from a previously generated WGS dataset. Variants associated with NUMTs were detected in the mtDNA alignments for 91 of 917 (~8%) Swedish samples when the 5% frequency threshold was applied. The 413 observed NUMT variants were predominantly detected in two regions (nps 12,612–13,105 and 16,390–16,527), which were consistent with previously documented NUMTs. The number of NUMT variants was reduced by ~97% (400) using a 10% frequency threshold. Furthermore, the 5% frequency data were inconsistent with a platinum-quality mitogenome dataset with respect to observed heteroplasmy. These analyses illustrate that a 10% variant detection threshold may be necessary to ensure the generation of reliable mitogenome haplotypes from WGS data resources.

23 February 2024 in Genes
Verified
Journal Article
Open access
PDF file
Muhammad ShahzadMuhammad Shahzad
Muhammad Shahzad
HMHanne De Maeyer
Hanne De Maeyer
GSGhassan Ali Salih
Ghassan Ali Salih
MNMartina Nilsson
Martina Nilsson
AHAnastasia Haratourian
Anastasia Haratourian
MAMarie Allen
Marie Allen
DNA analysis of traces from commonly found objects like knives, smartphones, tapes and garbage bags related to crime in aquatic environments is challenging for forensic DNA laboratories. The amount of recovered DNA may be affected by the water environment, time in the water, method for recovery, transport and storage routines of the objects before the objects arrive in the laboratory. The present study evaluated the effect of four storage conditions on the DNA retrieved from bloodstains, touch DNA, fingerprints and hairs, initially deposited on knives, smartphones, packing tapes, duct tapes and garbage bags, and submerged in lake water for three time periods. After retrieval, the objects were stored either through air-drying at room temperature, freezing at −30 °C, in nitrogen gas or in lake water. The results showed that the submersion time strongly influenced the amount and degradation of DNA, especially after the longest submersion time (21 days). A significant variation was observed in success for STR profiling, while mtDNA profiling was less affected by the submersion time interval and storage conditions. This study illustrates that retrieval from water as soon as possible and immediate storage through air-drying or freezing before DNA analysis is beneficial for the outcome of DNA profiling in crime scene investigations.