ticiane santa rita

Dr. ticiane santa rita


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2020 in Genes
Verified
Journal Article
Open access
PDF file
Gustavo Barcelos BarraGustavo Barcelos Barra
Gustavo Barcelos Barra
TRticiane santa rita
ticiane santa rita
PMPedro Mesquita
Pedro Mesquita
RJRafael Henriques Jacomo
Rafael Henriques Jacomo
LNLídia Freire Abdalla Nery
Lídia Freire Abdalla Nery
WHO declared the novel coronavirus (COVID-19) outbreak a global pandemic on 11 March 2020. The establishment of standardized RT-qPCR protocols for respiratory secretions testing, as well as sharing of specimens, data, and information became critical. Here, we investigate the analytical performance of two interim RT-qPCR protocols (Charité and Centers for Disease Control (CDC)) for the qualitative detection of SARS-CoV-2 executed in a fully automated platform. Analytical specificity, PCR amplification efficiency, analytical sensitivity (limit of detection), and cross-reactivity were evaluated using contrived samples. The on-going accuracy was evaluated by retrospective analysis of our test results database (real clinical samples). N1, E, and a modified version of RdRP assays presented adequate analytical specificity, amplification efficiency, and analytical sensitivity using contrived samples. The three assays were applied to all individuals who requested the SARS-CoV-2 molecular test assay in our laboratory and it was observed that N1 gave more positive results than E, and E gave more positive results than RdRP (modified). The RdRP and E were removed from the test and its final version, based on N1 assay only, was applied to 30,699 Brazilian individuals (from 19 February 2020 to 8 May 2020). The aggregated test results available in the database were also presented.

6 September 2017 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
TRticiane santa rita
ticiane santa rita
RBRenata Barcelos Barra
Renata Barcelos Barra
GPGisele Pasquali Peixoto
Gisele Pasquali Peixoto
PMPedro Mesquita
Pedro Mesquita
Gustavo Barcelos BarraGustavo Barcelos Barra
Gustavo Barcelos Barra
In early 2015, an outbreak of an acute exanthematous illness with dengue-like symptoms occurred in northeastern Brazil. By the end of the same year, an unexpected increase in the number of cases of microcephaly was observed in the region. The microcephaly outbreak cause was unknown and rumors pointing to various potential causes arose. Since we were unaware at the time if this scenario would attract the interest of the broader scientific community, due to the neglected regions associated and as often happens with many others health conditions related to infectious diseases in Latin America. This coupled with the fact that diagnostic testing for Zika virus was not available, prompted us to design a study that could demonstrate the correlation between the development of an exanthematous illness with Zika-like symptoms during pregnancy and the delivery of a newborn with congenital microcephaly. Mothers who experienced symptoms associated with the Zika virus during pregnancy had 10 times higher odds of delivering newborns with congenital microcephaly when compared with mothers who did not exhibit Zika-like symptoms. Thus, the acute exanthematous illness outbreak could be associated with the congenital microcephaly outbreak. We could not distinguish which virus caused the acute exanthematous illness in the study subjects (Zika, dengue or chikungunya), but these results could help to reduce the misquided speculation in regards to the cause of the microcephaly and could have expedited public health policies intended for controlling the mosquito vector. In addition to the lower head circumference, microcephalic neonates also had lower thoracic circumference, lower height and lower weight compared to non-microcephalic babies suggesting intrauterine growth restriction. Additionally, we found borderline association between mothers classified as homemakers and, who had past dengue infections with microcephaly. Prior contraction of dengue virus seems to play a role in the risk for the condition reflecting the domestication of the Aedes Aegypti and the enhancement of the Zika virus infection by dengue antibodies, respectively. The limitations of this study are: (a) participants recall bias, (b) absence of laboratory test results for Zika virus and other arboviruses and (c) incomplete test results for other pathogens that could lead to microcephaly. The study protocol was registered at ClinicalTrial.gov under the identifier NCT02741882. Registered on April 13th, 2016

12 March 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
Gustavo Barcelos BarraGustavo Barcelos Barra
Gustavo Barcelos Barra
TRticiane santa rita
ticiane santa rita
AAAna Luisa Almeida
Ana Luisa Almeida
RJRafael Henriques Jácomo
Rafael Henriques Jácomo
LNLídia Freire Abdalla Nery
Lídia Freire Abdalla Nery
Detection of the Janus Kinase-2 (JAK2) V617F mutation is a diagnostic criterion for myeloproliferative neoplasms, and high levels of mutant alleles are associated with worse outcomes. This mutation is usually tested on blood DNA by allele-specific qPCR (AS-qPCR) and measured using absolute quantification. However, some automated DNA extractions co-extracts of PCR inhibitors from blood and qPCR absolute quantification need increased efforts in order to maintain standard curves. JAK2 V617F can also be detected in serum using droplet digital PCR (ddPCR), a specimen with less inhibitors and favorable to automated extractions, but ddPCR instruments are not wide available as qPCR thermocyclers. Here, we evaluate whether JAK2 V617F could be accurately quantified by AS-qPCR using the 2-∆∆Cq method on blood DNA and validate the assay using gold-standard molecular diagnostic protocols. Next, we apply the validated method to assess if the mutation could be reliably detected/quantified in serum. JAK2 V617F could be quantified by AS-qPCR using the 2-∆∆Cq method—the assay was highly accurate (bias of 1.91%) compared to a commercial kit, highly precise (total CV% of 0.40%, 1.92%, 11.12% for samples with 93%, 54%, and 2.5% of mutant allele), highly sensitive (limit of detection of 0.15%), and demonstrated a linear detection response from 1.1% to 99.9%. Serum presented a higher mutant allele burden compared to the paired whole blood (mean of 4%), which allows for an increased JAK2 mutant detection rate and favors increased JAK2 V617F high-throughput analysis.

11 January 2019 in Diagnostics
Verified
Journal Article
Open access
PDF file
Gustavo Barcelos BarraGustavo Barcelos Barra
Gustavo Barcelos Barra
TRticiane santa rita
ticiane santa rita
DJDaniella Paniago Jardim
Daniella Paniago Jardim
PMPedro Mesquita
Pedro Mesquita
CNCamila Santos Nobre
Camila Santos Nobre
LNLídia Freire Abdalla Nery
Lídia Freire Abdalla Nery
The cell-free genomic DNA (gDNA) concentration in serum ranges from 1500 to 7500 copies/mL within 2 h after phlebotomy (6–24 times the concentration observed in plasma). Here, we aimed to evaluate the gDNA size distribution in serum with time after coagulation and to test if crude serum can be directly used as a source of gDNA for qPCR. Next, we investigated if single nucleotide polymorphisms (SNPs) could be genotyped directly from the crude serum isolated from capillary blood using a hand-powered paper centrifuge. All tested PCR targets (65, 100, 202 and 688 base pairs) could be successfully amplified from DNA extracted from serum, irrespective of their amplicon size. The observed qPCR quantitation cycles suggested that the genomic DNA yield increased in serum with incubation at room temperature. Additionally, only 65 and 101 base pair qPCR targets could be amplified from crude serum soon after the coagulation. Incubation for 4 days at room temperature was necessary for the amplification of PCR targets of 202 base pairs. The 688 base pair qPCR target could not be amplified from serum directly. Lastly, serum was successfully separated from capillary blood using the proposed paper centrifuge and the genotypes were assigned by testing the crude serum using allele-specific qPCR, producing small amplicon sizes in complete agreement with the genotypes assigned by testing the DNA extracted from whole blood. The serum can be used directly as the template in qPCR for SNP genotyping, especially if small amplicon sizes are applied. This shortcut in the SNP genotyping process could further molecular point-of-care diagnostics due to elimination of the DNA extraction step.

3 March 2025 in LabMed
Verified
Journal Article
Open access
PDF file
Gustavo Barcelos BarraGustavo Barcelos Barra
Gustavo Barcelos Barra
TRticiane santa rita
ticiane santa rita
RJRafael Henriques Jacomo
Rafael Henriques Jacomo
LNLídia Freire Abdalla Nery
Lídia Freire Abdalla Nery
Cell-free DNA (cfDNA) analysis is a pivotal tool in non-invasive diagnostics, including cancer monitoring and prenatal testing. However, the preanalytical phase, particularly the choice of anticoagulant, significantly impacts cfDNA integrity and yield. This study aims to compare cfDNA yield, stability, and DNase activity in plasma-citrate and plasma-heparin, using plasma-EDTA and serum as established controls, to explore more deeply the impact of blood DNAse activity on cfDNA in these specimens. Blood samples from 15 healthy volunteers were collected in four types of tubes (citrate, heparin, EDTA, and serum). cfDNA was extracted and quantified using qPCR, and endogenous DNase activity was assessed through hydrolysis probe assays. Samples were incubated at 37 °C for 24 h to evaluate cfDNA degradation rates. Heparin-plasma exhibited the highest DNase activity, with baseline cfDNA levels intermediate—higher than EDTA but lower than serum—leading to substantial cfDNA degradation (85.3%). Combined with its known PCR inhibition, this renders heparin-plasma unsuitable for cfDNA analysis. Citrate-plasma, with baseline cfDNA levels similar to EDTA, showed partial DNase inhibition, resulting in intermediate cfDNA degradation (13.3%), a limitation that diminishes its viability compared to EDTA-plasma. Serum, with the highest baseline cfDNA levels, exhibited high DNase activity and significant cfDNA degradation (55.6%), making it unsuitable for cfDNA preservation. EDTA-plasma demonstrated complete DNase inhibition and minimal cfDNA degradation (8%), confirming it as the most suitable specimen for cfDNA analysis. These findings emphasize the importance of anticoagulant selection, highlighting critical limitations of heparin-plasma and citrate-plasma while reinforcing EDTA-plasma as the gold standard for preserving cfDNA integrity in diagnostic applications.

10 September 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Gustavo Barcelos BarraGustavo Barcelos Barra
Gustavo Barcelos Barra
TRticiane santa rita
ticiane santa rita
RJRafael Henriques Jacomo
Rafael Henriques Jacomo
LNLídia Freire Abdalla Nery
Lídia Freire Abdalla Nery
Cell-free DNA (cfDNA) analysis is a pivotal tool in non-invasive diagnostics, including cancer monitoring and prenatal testing. However, the preanalytical phase, particularly the choice of anticoagulant, significantly impacts cfDNA integrity and yield. This study aims to compare cfDNA yield, stability, and DNase activity across plasma-citrate, plasma-heparin, plasma-EDTA, and serum, to identify the most suitable specimen for cfDNA analysis among the tested anticoagulants. Blood samples from 15 healthy volunteers were collected in four types of tubes (citrate, heparin, EDTA, and serum). cfDNA was extracted and quantified using qPCR, and endogenous DNase activity was assessed through hydrolysis probe assays. Samples were incubated at 37°C for 24 hours to evaluate cfDNA degradation rates. Statistical analyses were performed using repeated measures ANOVA and Sidak's multiple comparison tests. Baseline cfDNA levels were highest in serum, followed by heparin-plasma, while EDTA and citrate-plasma exhibited the lowest levels. DNase activity was fully inhibited in EDTA-plasma, partially inhibited in citrate-plasma, and active in both heparin-plasma and serum. cfDNA degradation was most pronounced in heparin-plasma (85.3%) and serum (55.6%), compared to minimal degradation in EDTA (8%) and citrate-plasma (13.3%). Among the tested anticoagulants, EDTA-plasma proved to be the most suitable specimen for cfDNA analysis due to its low DNase activity and minimal gDNA contamination. Citrate-plasma, with intermediate DNase inhibition, could be an alternative if the citrate concentration were increased. Heparin-plasma and serum showed significant cfDNA degradation, rendering them unsuitable for cfDNA analysis. These findings highlight the importance of anticoagulant selection in preserving cfDNA integrity for diagnostic applications.