Yaowen Zhang

Ms. Yaowen Zhang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2023 in Radiotherapy and Oncology
Verified
Journal Article
Open access
FNFaegheh Noorian
Faegheh Noorian
RARosa Abellana
Rosa Abellana
YZYaowen Zhang
Yaowen Zhang
AMAntonio Herreros Martínez
Antonio Herreros Martínez
CBClara Baltrons
Clara Baltrons
Ángeles RovirosaÁngeles Rovirosa
Ángeles Rovirosa
To compare two vaginal brachytherapy (VBT) schedules in postoperative endometrial carcinoma (PEC) patients considering vaginal-cuff relapses (VCR), late toxicities, dosimetry analysis and vaginal dilator use. 110 PEC patients were treated with exclusive high-dose-rate VBT using two schedules. Group-1:44-patients received 6 Gy×3fractions (September-2011-April-2014); Group-2:66-patients were treated with 7.5 Gy×2fractions with a dose limit of equivalent total doses in 2-Gy fr (EQD2(α/β=3)) of 68 Gy in the most exposed 2 cm3 of clinical target volume (CTV) (July-2015-November-2021). The dose was prescribed at 5 mm from the applicator surface. Were evaluated the overall radiation dose delivered to 90% of the CTV (D90), the CTV receiving 100% of the prescription dose (V100) and the EQD2(α/β=3) received in the most exposed 2 cm3 to dose in CTV. Late toxicity was prospectively assessed using RTOG scores for bladder and rectum and objective LENT-SOMA criteria for late vaginal toxicity (LVT). Descriptive analysis, Chi-square, Student's t-tests and Kaplan and Meier method. The median follow-up was 60 months (15.9-60). There were no VCR or late toxicities in bladder or rectum. LVT ≥ G1 appeared in 26/44 (59.1%) in Group-1 and 25/66 (37.9%) in Group-2. The mean EQD2(α/β=3) received by the most exposed 2 cm3 of CTV was 63.7 Gy ± 10.0 in Group-1 and 60.5 Gy ± 3.8 in Group-2 (p = 0.063). There were no differences in adherence to vaginal dilator use ≥9 months, overall D90 and V100. Considering the lack of vaginal relapses and similar LVT over time, 7.5 Gy×2fractions seem more efficient in terms of patient comfort, workload, and cost. This is the first study using dosimetry parameters to compare effectivity of schedules. Larger series are needed to confirm the present results.

Verified
Journal Article
Open access
PDF file
FNFaegheh Nooriankafshgari
Faegheh Nooriankafshgari
RARosa Abellana
Rosa Abellana
YZYaowen Zhang
Yaowen Zhang
AMAntonio Herreros Martínez
Antonio Herreros Martínez
VLValentina Lancellotta
Valentina Lancellotta
Ángeles RovirosaÁngeles Rovirosa
Ángeles Rovirosa
Background: This study evaluated the clinical outcomes of applying a 68 Gy EQD2(α/β=3) dose constraint to the most exposed 2 cm3 area of the vagina in post-operative endometrial cancer patients treated with vaginal-cuff brachytherapy after external beam irradiation and the impact of vaginal dilator use on late vaginal complications. Material and methods: We analyzed 131 patients treated with vaginal-cuff brachytherapy after external beam irradiation. Group-1 (65 patients) received one fraction of 7 Gy, and Group-2 (66 patients) received one fraction of between 5.5 and 7.0 Gy after applying a 68 Gy EQD2(α/β=3) dose constraint. Vaginal-cuff relapse, late toxicity, clinical target volume, vaginal dilator use, D90, and EQD2(α/β=3) at 2 cm3 of the most exposed part of the clinical target volume were evaluated. Descriptive analysis, the chi-squared test, Student’s t-test, and the Cox proportional and Kaplan–Meier models were used for the statistical analysis. Results: With a median follow-up of 60 months, the vaginal-cuff relapse rate was 1/131 (0.8%). Late vaginal complications appeared in 36/65 (55.4%) Group-1 patients and 17/66 (25.8%) Group-2 patients (p = 0.003). Multivariate analysis showed that belonging to Group-1 and vaginal dilator use of <9 months were independent prognostic factors of late vaginal complications with hazard ratios of 1.99 (p = 0.021) and 3.07 (p = 0.010), respectively. Conclusions: A 68 Gy EQD2(α/β=3) constraint at 2 cm3 of clinical target volume and vaginal dilator use of ≥9 months were independent prognostic factors, having protective effects on late vaginal complications.