Vygandas Rutkunas

Prof. Vygandas Rutkunas

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2020 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
FMFrancesco Mangano
Francesco Mangano
OAOleg Admakin
Oleg Admakin
MBMatteo Bonacina
Matteo Bonacina
HLHenriette Lerner
Henriette Lerner
VRVygandas Rutkunas
Vygandas Rutkunas
Carlo  ManganoCarlo Mangano
Carlo Mangano
Background: The literature has not yet validated the use of intraoral scanners (IOSs) for full-arch (FA) implant impression. Hence, the aim of this in vitro study was to assess and compare the trueness of 12 different IOSs in FA implant impression. Methods: A stone-cast model of a totally edentulous maxilla with 6 implant analogues and scanbodies (SBs) was scanned with a desktop scanner (Freedom UHD®) to capture a reference model (RM), and with 12 IOSs (ITERO ELEMENTS 5D®; PRIMESCAN® and OMNICAM®; CS 3700® and CS 3600®; TRIOS3®; i-500®; EMERALD S® and EMERALD®; VIRTUO VIVO® and DWIO®; RUNEYES QUICKSCAN®). Ten scans were taken using each IOS, and each was compared to the RM, to evaluate trueness. A mesh/mesh method and a nurbs/nurbs method were used to evaluate the overall trueness of the scans; linear and cross distances between the SBs were used to evaluate the local trueness of the scans. The analysis was performed using reverse engineering software (Studio®, Geomagics; Magics®, Materialise). A statistical evaluation was performed. Results: With the mesh/mesh method, the best results were obtained by CS 3700® (mean error 30.4 μm) followed by ITERO ELEMENTS 5D® (31.4 μm), i-500® (32.2 μm), TRIOS 3® (36.4 μm), CS 3600® (36.5 μm), PRIMESCAN® (38.4 μm), VIRTUO VIVO® (43.8 μm), RUNEYES® (44.4 μm), EMERALD S® (52.9 μm), EMERALD® (76.1 μm), OMNICAM® (79.6 μm) and DWIO® (98.4 μm). With the nurbs/nurbs method, the best results were obtained by ITERO ELEMENTS 5D® (mean error 16.1 μm), followed by PRIMESCAN® (19.3 μm), TRIOS 3® (20.2 μm), i-500® (20.8 μm), CS 3700® (21.9 μm), CS 3600® (24.4 μm), VIRTUO VIVO® (32.0 μm), RUNEYES® (33.9 μm), EMERALD S® (36.8 μm), OMNICAM® (47.0 μm), EMERALD® (51.9 μm) and DWIO® (69.9 μm). Statistically significant differences were found between the IOSs. Linear and cross distances between the SBs (local trueness analysis) confirmed the data that emerged from the overall trueness evaluation. Conclusions: Different levels of trueness were found among the IOSs evaluated in this study. Further studies are needed to confirm these results.

30 September 2014 in Micromachines
Verified
Journal Article
Open access
PDF file
MMMangirdas Malinauskas
Mangirdas Malinauskas
SRSima Rekštytė
Sima Rekštytė
LLLaurynas Lukoševičius
Laurynas Lukoševičius
SBSimas Butkus
Simas Butkus
EBEvaldas Balciunas
Evaldas Balciunas
Saulius JuodkazisSaulius Juodkazis
Saulius Juodkazis
A 3D printing fused filament fabrication (FFF) approach has been implemented for the creation of microstructures having an internal 3D microstructure geometry. These objects were produced without any sacrificial structures or additional support materials, just by precisely tuning the nozzle heating, fan cooling and translation velocity parameters. The manufactured microporous structures out of polylactic acid (PLA) had fully controllable porosity (20%–60%) and consisted of desired volume pores (~0.056 μm3). The prepared scaffolds showed biocompatibility and were suitable for the primary stem cell growth. In addition, direct laser writing (DLW) ablation was employed to modify the surfaces of the PLA structures, drill holes, as well as shape the outer geometries of the created objects. The proposed combination of FFF printing with DLW offers successful fabrication of 3D microporous structures with functionalization capabilities, such as the modification of surfaces, the generation of grooves and microholes and cutting out precisely shaped structures (micro-arrows, micro-gears). The produced structures could serve as biomedical templates for cell culturing, as well as biodegradable implants for tissue engineering. The additional micro-architecture is important in connection with the cell types used for the intention of cell growing. Moreover, we show that surface roughness can be modified at the nanoscale by immersion into an acetone bath, thus increasing the hydrophilicity. The approach is not limited to biomedical applications, it could be employed for the manufacturing of bioresorbable 3D microfluidic and micromechanic structures.

1 January 2010 in Dental Materials Journal
Verified
Journal Article
Closed access
PDF file
VRVygandas Rutkunas
Vygandas Rutkunas
VSVaidotas Sabaliauskas
Vaidotas Sabaliauskas
HMHiroshi Mizutani
Hiroshi Mizutani
The main objective was to investigate the effects of different polishing techniques on the color stability of provisional prosthetic materials upon exposure to different staining agents by mimicking the oral environment in vitro. Fifty-six cylindrical specimens were prepared for each type of material: bis-acryl and light-polymerized composite resins, and methyl methacrylate- and ethyl methacrylatebased resins. The specimens were polished using seven different polishing techniques and then immersed in four different staining agents. Color was measured with a spectrophotometer before and after immersion, and color changes (ΔE) were calculated. The effects of the type of provisional material, polishing procedure, staining agent, and their interactions on color stability were significant (p<0.05). Amongst these factors, the staining agent exerted the strongest effect on color stability. Amongst the provisional materials tested, methacrylate-based resins exhibited the highest color stability irrespective of polishing technique and staining agent.

1 April 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
IGIeva Gendviliene
Ieva Gendviliene
ESEgidijus Simoliunas
Egidijus Simoliunas
SRSima Rekstyte
Sima Rekstyte
MMMangirdas Malinauskas
Mangirdas Malinauskas
LZLinas Zaleckas
Linas Zaleckas
VRVygandas Rutkunas
Vygandas Rutkunas

9 June 2006 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
VRVygandas Rutkunas
Vygandas Rutkunas
HMH. Mizutani
H. Mizutani
HTH. Takahashi
H. Takahashi

1 January 2011 in Dental Materials Journal
Verified
Journal Article
Closed access
VRVygandas Rutkunas
Vygandas Rutkunas
HMHiroshi Mizutani
Hiroshi Mizutani
HTHidekazu Takahashi
Hidekazu Takahashi
NINaohiko Iwasaki
Naohiko Iwasaki
The aim of this study was to evaluate wear effects on overdenture resilient attachments. Six commercially available attachments were investigated: ERA orange and white (EO and EW), Locator pink, white and blue (LRP, LRW and LRB) and OP anchor (OP). Five specimens were used for wear simulation while other two specimens served as controls. Fifteen thousands insertion-removal cycles were simulated. Dimensional changes and surface characteristics were evaluated using light microscopy and SEM, respectively. Sudden decrease of retentive force was characteristic for EO and EW attachments. Retentive force of Locator attachments fluctuated throughout the wear simulation period. Dimensional changes and surface wear was more expressed on plastic cores than on plastic rings of attachment males. Based on SEM analysis, some of the specimens obtained smoother surface after wear simulation. Mechanism of retention loss of resilient overdenture attachments can be only partially explained by dimensional changes and surface alterations.