Nuankanya Sathirapongsasuti

Dr. Nuankanya Sathirapongsasuti

Mahidol Univerisy
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2022 in Journal of Biological Chemistry
Verified
Journal Article
Open access
KDKassaporn Duangkumpha
Kassaporn Duangkumpha
NJNarumol Jariyasopit
Narumol Jariyasopit
KWKwanjeera Wanichthanarak
Kwanjeera Wanichthanarak
EDEsha Dhakal
Esha Dhakal
PWPattipong Wisanpitayakorn
Pattipong Wisanpitayakorn
SKSakda Khoomrung
Sakda Khoomrung
Two dimensional GC (GC × GC)–time-of-flight mass spectrometry (TOFMS) has been used to improve accurate metabolite identification in the chemical industry, but this method has not been applied as readily in biomedical research. Here, we evaluated and validated the performance of high resolution GC × GC-TOFMS against that of GC-TOFMS for metabolomics analysis of two different plasma matrices, from healthy controls (CON) and diabetes mellitus (DM) patients with kidney failure (DM with KF). We found GC × GC-TOFMS outperformed traditional GC-TOFMS in terms of separation performance and metabolite coverage. Several metabolites from both the CON and DM with KF matrices, such as carbohydrates and carbohydrate-conjugate metabolites, were exclusively detected using GC × GC-TOFMS. Additionally, we applied this method to characterize significant metabolites in the DM with KF group, with focused analysis of four metabolite groups: sugars, sugar alcohols, amino acids, and free fatty acids. Our plasma metabolomics results revealed 35 significant metabolites (12 unique and 23 concentration-dependent metabolites) in the DM with KF group, as compared with those in the CON and DM groups (N = 20 for each group). Interestingly, we determined 17 of the 35 (14/17 verified with reference standards) significant metabolites identified from both the analyses were metabolites from the sugar and sugar alcohol groups, with significantly higher concentrations in the DM with KF group than in the CON and DM groups. Enrichment analysis of these 14 metabolites also revealed that alterations in galactose metabolism and the polyol pathway are related to DM with KF. Overall, our application of GC × GC-TOFMS identified key metabolites in complex plasma matrices.

NSNuankanya Sathirapongsasuti
Nuankanya Sathirapongsasuti
KKKasetsin Khonchom
Kasetsin Khonchom
TPThunyaporn Poonsawat
Thunyaporn Poonsawat
MPMitila Pransilpa
Mitila Pransilpa
SOSupaporn Ongsara
Supaporn Ongsara
STSatariya Trakulsrichai
Satariya Trakulsrichai
Box jellyfish are extremely potent venom-producing marine organisms. While they have been found worldwide, the highest health burden has been anticipated to be the tropical Indo-Pacific of Southeast Asia (SEA). At least 12 Cubozoan species have now been documented in Thai waters, and many of them inflict acutely lethal strings, especially those under the order Chirodropida. Our previous study has successfully differentiated species of box jellyfish using DNA sequencing to support the morphological study. In this study, we specifically designed polymerase chain reaction (PCR) primers for the 16S ribosomal RNA (rRNA) gene and the mitochondrial DNA cytochrome oxidase subunit I (COI) gene of lethal Thai Chironex species. The SYBR green-based real-time PCR panel was performed for rapid species identification. The sensitivity and specificity of the panel were determined by testing samples of different species. Moreover, we applied the panel to the tentacle sample from a real patient, which helped confirm the animal-of-cause of envenomation. Our results show a success for species identification of box jellyfish using 16S rRNA and COI PCR panel, which revealed congruence between molecular and morphological identification. Furthermore, the panel worked very well with the unknown samples and jellyfish tissue from the real envenomation case. The results demonstrated that molecular panels were able to identify three species of Chironex box jellyfish both rapidly and accurately, and can be performed without having a complete specimen or morphological study.

11 January 2022 in Briefings in Bioinformatics
Verified
Journal Article
Open access
PDF file
VMVivek Bhakta Vivek Bhakta Mathema
Vivek Bhakta Vivek Bhakta Mathema
KDKassaporn Duangkumpha
Kassaporn Duangkumpha
KWKwanjeera Wanichthanarak
Kwanjeera Wanichthanarak
NJNarumol Jariyasopit
Narumol Jariyasopit
EDEsha Dhakal
Esha Dhakal
SKSakda Khoomrung
Sakda Khoomrung
Two-dimensional gas chromatography–time-of-flight mass spectrometry (GC × GC–TOFMS) provides a large amount of molecular information from biological samples. However, the lack of a comprehensive compound library or customizable bioinformatics tool is currently a challenge in GC × GC–TOFMS data analysis. We present an open-source deep learning (DL) software called contour regions of interest (ROI) identification, simulation and untargeted metabolomics profiler (CRISP). CRISP integrates multiple customizable deep neural network architectures for assisting the semi-automated identification of ROIs, contour synthesis, resolution enhancement and classification of GC × GC–TOFMS-based contour images. The approach includes the novel aggregate feature representative contour (AFRC) construction and stacked ROIs. This generates an unbiased contour image dataset that enhances the contrasting characteristics between different test groups and can be suitable for small sample sizes. The utility of the generative models and the accuracy and efficacy of the platform were demonstrated using a dataset of GC × GC–TOFMS contour images from patients with late-stage diabetic nephropathy and healthy control groups. CRISP successfully constructed AFRC images and identified over five ROIs to create a deepstacked dataset. The high fidelity, 512 × 512-pixels generative model was trained as a generator with a Fréchet inception distance of 0.96 and a classification accuracy of >95.00% for datasets with and without column bleed. Overall, CRISP demonstrates good potential as a DL-based approach for the rapid analysis of 4-D GC × GC–TOFMS untargeted metabolite profiles by directly implementing contour images. CRISP is available at https://github.com/vivekmathema/GCxGC-CRISP.

22 June 2021 in Polymers
Verified
Journal Article
Open access
PDF file
NSNuankanya Sathirapongsasuti
Nuankanya Sathirapongsasuti
APAnuchan Panaksri
Anuchan Panaksri
SBSani Boonyagul
Sani Boonyagul
SCSomchai Chutipongtanate
Somchai Chutipongtanate
Nuttapol TanadchangsaengNuttapol Tanadchangsaeng
Nuttapol Tanadchangsaeng
The adsorption of proteins on membranes has been used for simple, low-cost, and minimal sample handling of large volume, low protein abundance liquid samples. Syringe-push membrane absorption (SPMA) is an innovative way to process bio-fluid samples by combining a medical syringe and protein-absorbable membrane, which makes SPMA a simple, rapid protein and proteomic analysis method. However, the membrane used for SPMA is only limited to commercially available protein-absorbable membrane options. To raise the method’s efficiency, higher protein binding capacity with a lower back pressure membrane is needed. In this research, we fabricated electrospun polybutylene succinate (PBS) membrane and compared it to electrospun polyvinylidene fluoride (PVDF). Rolling electrospinning (RE) and non-rolling electrospinning (NRE) were employed to synthesize polymer fibers, resulting in the different characteristics of mechanical and morphological properties. Adding graphene oxide (GO) composite does not affect their mechanical properties; however, electrospun PBS membrane can be applied as a filter membrane and has a higher pore area than electrospun PVDF membrane. Albumin solution filtration was performed using all the electrospun filter membranes by the SPMA technique to measure the protein capture efficiency and staining of the protein on the membranes, and these membranes were compared to the commercial filter membranes—PVDF, nitrocellulose, and Whatman no. 1. A combination of rolling electrospinning with graphene oxide composite and PBS resulted in two times more captured protein when compared to commercial membrane filtration and more than sixfold protein binding than non-composite polymer. The protein staining results further confirmed the enhancement of the protein binding property, showing more intense stained color in compositing polymer with GO.