Yan Wang

Dr. Yan Wang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
QTQitao TAN
Qitao TAN
YWYan Wang
Yan Wang
TCTony Lin-Wei Chen
Tony Lin-Wei Chen
DWDuo Wai-Chi Wong
Duo Wai-Chi Wong
FYFei Yan
Fei Yan
MZMing Zhang
Ming Zhang
This research aims to investigate the development of muscle fatigue and the recovery process revealed by tissue oxygenation. The tissue hemodynamics were measured by near-infrared spectroscopy (NIRS) during a 30-min pre-exercise rest, a 40-cycle heel-lift exercise and a 30-min post-exercise recovery. Wavelet transform was used to obtain the normalized wavelet energy in six frequency intervals (I–VI) and inverse wavelet transform was applied to extract exercise-induced oscillations from the hemodynamic signals. During the exercise phase, the contraction-related oscillations in the total hemoglobin signal (ΔtHb) showed a decreasing trend while the fluctuations in the tissue oxygenation index (TOI) displayed an increasing tendency. The mean TOI value was significantly higher (p < 0.001) under recovery (65.04% ± 2.90%) than that under rest (62.35% ± 3.05%). The normalized wavelet energy of the ΔtHb signal in frequency intervals I (p < 0.001), II (p < 0.05), III (p < 0.05) and IV (p < 0.01) significantly increased by 43.4%, 23.6%, 18.4% and 21.6% during the recovery than that during the pre-exercise rest, while the value in interval VI (p < 0.05) significantly decreased by 16.6%. It could be concluded that NIRS-derived hemodynamic signals can provide valuable information related to muscle fatigue and recovery.

8 July 2022 in Biology
Verified
Journal Article
Open access
PDF file
THTommy Tung-Ho Hong
Tommy Tung-Ho Hong
YWYan Wang
Yan Wang
DWDuo Wai-Chi Wong
Duo Wai-Chi Wong
GZGuoxin Zhang
Guoxin Zhang
QTQitao TAN
Qitao TAN
MZMing Zhang
Ming Zhang
Sleeping support systems can influence spinal curvature, and the misalignment of the spinal curvature can lead to musculoskeletal problems. Previous sleep studies on craniocervical support focused on pillow variants, but the mattress supporting the pillow has rarely been considered. This study used a cervical pillow and three mattresses of different stiffnesses, namely soft, medium, and hard, with an indentation load deflection of 20, 42, and 120 lbs, respectively. A novel electronic curvature measurement device was adopted to measure the spinal curvature, whereby the intervertebral disc loading was computed using the finite element method. Compared with the medium mattress, the head distance increased by 30.5 ± 15.9 mm, the cervical lordosis distance increased by 26.7 ± 14.9 mm, and intervertebral disc peak loading increased by 49% in the soft mattress environment. Considering that the pillow support may increase when using a soft mattress, a softer or thinner pillow is recommended. The head distance and cervical lordosis distance in the hard mattress environment were close to the medium mattress, but the lumbar lordosis distance reduced by 10.6 ± 6.8 mm. However, no significant increase in intervertebral disc loading was observed, but contact pressure increased significantly, which could cause discomfort and health problems.

7 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
GZGuoxin Zhang
Guoxin Zhang
IWIvy Kwan-Kei Wong
Ivy Kwan-Kei Wong
TCTony Lin-Wei Chen
Tony Lin-Wei Chen
THTommy Tung-Ho Hong
Tommy Tung-Ho Hong
DWDuo Wai-Chi Wong
Duo Wai-Chi Wong
MZMing Zhang
Ming Zhang
Real-time detection of fatigue in the elderly during physical exercises can help identify the stability and thus falling risks which are commonly achieved by the investigation of kinematic parameters. In this study, we aimed to identify the change in gait variability parameters from inertial measurement units (IMU) during a course of 60 min brisk walking which could lay the foundation for the development of fatigue-detecting wearable sensors. Eighteen elderly people were invited to participate in the brisk walking trials for 60 min with a single IMU attached to the posterior heel region of the dominant side. Nine sets of signals, including the accelerations, angular velocities, and rotation angles of the heel in three anatomical axes, were measured and extracted at the three walking times (baseline, 30th min, and 60th min) of the trial for analysis. Sixteen of eighteen participants reported fatigue after walking, and there were significant differences in the median acceleration (p = 0.001), variability of angular velocity (p = 0.025), and range of angle rotation (p = 0.0011), in the medial–lateral direction. In addition, there were also significant differences in the heel pronation angle (p = 0.005) and variability and energy consumption of the angles in the anterior–posterior axis (p = 0.028, p = 0.028), medial–lateral axis (p = 0.014, p = 0.014), and vertical axis (p = 0.002, p < 0.001). Our study demonstrated that a single IMU on the posterior heel of the dominant side can address the variability of kinematics parameters for elderly performing prolonged brisk walking and could serve as an indicator for walking instability, and thus fatigue.

6 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
GZGuoxin Zhang
Guoxin Zhang
DWDuo Wai-Chi Wong
Duo Wai-Chi Wong
IWIvy Kwan-Kei Wong
Ivy Kwan-Kei Wong
TCTony Lin-Wei Chen
Tony Lin-Wei Chen
THTommy Tung-Ho Hong
Tommy Tung-Ho Hong
MZMing Zhang
Ming Zhang
Evaluation of potential fatigue for the elderly could minimize their risk of injury and thus encourage them to do more physical exercises. Fatigue-related gait instability was often assessed by the changes of joint kinematics, whilst planar pressure variability and asymmetry parameters may complement and provide better estimation. We hypothesized that fatigue condition (induced by the treadmill brisk-walking task) would lead to instability and could be reflected by the variability and asymmetry of plantar pressure. Fifteen elderly adults participated in the 60-min brisk walking trial on a treadmill without a pause, which could ensure that the fatigue-inducing effect is continuous and participants will not recover halfway. The plantar pressure data were extracted at baseline, the 30th minute, and the 60th minute. The median of contact time, peak pressure, and pressure-time integrals in each plantar region was calculated, in addition to their asymmetry and variability. After 60 min of brisk walking, there were significant increases in peak pressure at the medial and lateral arch regions, and central metatarsal regions, in addition to their impulses (p < 0.05). In addition, the variability of plantar pressure at the medial arch was significantly increased (p < 0.05), but their asymmetry was decreased. On the other hand, the contact time was significantly increased at all plantar regions (p < 0.05). The weakened muscle control and shock absorption upon fatigue could be the reason for the increased peak pressure, impulse, and variability, while the improved symmetry and prolonged plantar contact time could be a compensatory mechanism to restore stability. The outcome of this study can facilitate the development of gait instability or fatigue assessment using wearable in-shoe pressure sensors.

1 July 2021 in Clinical Biomechanics
Verified
Journal Article
Closed access
YWYating Wei
Yating Wei
CLCecilia W.P. Li-Tsang
Cecilia W.P. Li-Tsang
JWJun Wu
Jun Wu
WZWalei Zhang
Walei Zhang
YZYingying Zhang
Yingying Zhang
YWYan Wang
Yan Wang

28 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
QTQitao TAN
Qitao TAN
YWYan Wang
Yan Wang
ZLZengyong Li
Zengyong Li
DWDAIFA WANG
DAIFA WANG
WLWing Kai Lam
Wing Kai Lam
MZMing Zhang
Ming Zhang
Spectral analysis of blood flow or blood volume oscillations can help to understand the regulatory mechanisms of microcirculation. This study aimed to explore the relationship between muscle hemodynamic response in the recovery period and exercise quantity. Fifteen healthy subjects were required to perform two sessions of submaximal plantarflexion exercise. The blood volume fluctuations in the gastrocnemius lateralis were recorded in three rest phases (before and after two exercise sessions) using near-infrared spectroscopy. Wavelet transform was used to analyze the total wavelet energy of the concerned frequency range (0.005–2 Hz), which were further divided into six frequency intervals corresponding to six vascular regulators. Wavelet amplitude and energy of each frequency interval were analyzed. Results showed that the total energy raised after each exercise session with a significant difference between rest phases 1 and 3. The wavelet amplitudes showed significant increases in frequency intervals I, III, IV, and V from phase 1 to 3 and in intervals III and IV from phase 2 to 3. The wavelet energy showed similar changes with the wavelet amplitude. The results demonstrate that local microvascular regulators contribute greatly to the blood volume oscillations, the activity levels of which are related to the exercise quantity.