Randy Purves

Dr. Randy Purves

University of Saskatchewan, College of Pharmacy and Nutrition
+1
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 1999 in Analytical Chemistry
Verified
Journal Article
Closed access
Randy PurvesRandy Purves
Randy Purves
RGRoger Guevremont
Roger Guevremont

1 December 1998 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
Randy PurvesRandy Purves
Randy Purves
RGRoger Guevremont
Roger Guevremont
SDStephen Day
Stephen Day
CPCharles W. Pipich
Charles W. Pipich
MMMatthew S. Matyjaszczyk
Matthew S. Matyjaszczyk
Ion mobility spectrometry (IMS) has become an important method for the detection of many compounds because of its high sensitivity and amenability to miniaturization for field-portable monitoring; applications include detection of narcotics, explosives, and chemical warfare agents. High-field asymmetric waveform ion mobility spectrometry (FAIMS) differs from IMS in that the electric fields are applied using a high-frequency periodic asymmetric waveform, rather than a dc voltage. Furthermore, in FAIMS the compounds are separated by the difference in the mobility of ions at high electric field relative to low field, rather than by compound to compound differences in mobility at low electric field (IMS). We report here the first cylindrical-geometry-FAIMS interface with mass spectrometry (FAIMS-MS) and the MS identification of the peaks observed in a FAIMS compensation voltage (CV) spectrum. Using both an electrometer-based-FAIMS (FAIMS-E) and FAIMS-MS, several variables that affect the sensitivity of ion detection were examined for two (polarity reversed) asymmetric waveforms (modes 1 and 2) each of which yields a unique spectrum. An increase in the dispersion voltage (DV) was found to improve the sensitivity and separation observed in the FAIMS CV spectrum. This increase in sensitivity and the unexpected dissimilarity in modes 1 and 2 suggest that atmospheric pressure ion focusing is occurring in the FAIMS analyzer. The sensitivity and peak locations in the CV spectra were affected by temperature, gas flow rates, operating pressure, and analyte concentration.

21 February 2012 in The Plant Journal
Verified
Journal Article
Open access
PDF file
JSJake M. Stout
Jake M. Stout
ZBZakia Boubakir
Zakia Boubakir
SAStephen J. Ambrose
Stephen J. Ambrose
Randy PurvesRandy Purves
Randy Purves
JPJonathan E. Page
Jonathan E. Page
Summary: The psychoactive and analgesic cannabinoids (e.g. Δ9‐tetrahydrocannabinol (THC)) in Cannabis sativa are formed from the short‐chain fatty acyl‐coenzyme A (CoA) precursor hexanoyl‐CoA. Cannabinoids are synthesized in glandular trichomes present mainly on female flowers. We quantified hexanoyl‐CoA using LC‐MS/MS and found levels of 15.5 pmol g−1 fresh weight in female hemp flowers with lower amounts in leaves, stems and roots. This pattern parallels the accumulation of the end‐product cannabinoid, cannabidiolic acid (CBDA). To search for the acyl‐activating enzyme (AAE) that synthesizes hexanoyl‐CoA from hexanoate, we analyzed the transcriptome of isolated glandular trichomes. We identified 11 unigenes that encoded putative AAEs including CsAAE1, which shows high transcript abundance in glandular trichomes. In vitro assays showed that recombinant CsAAE1 activates hexanoate and other short‐ and medium‐chained fatty acids. This activity and the trichome‐specific expression of CsAAE1 suggest that it is the hexanoyl‐CoA synthetase that supplies the cannabinoid pathway. CsAAE3 encodes a peroxisomal enzyme that activates a variety of fatty acid substrates including hexanoate. Although phylogenetic analysis showed that CsAAE1 groups with peroxisomal AAEs, it lacked a peroxisome targeting sequence 1 (PTS1) and localized to the cytoplasm. We suggest that CsAAE1 may have been recruited to the cannabinoid pathway through the loss of its PTS1, thereby redirecting it to the cytoplasm. To probe the origin of hexanoate, we analyzed the trichome expressed sequence tag (EST) dataset for enzymes of fatty acid metabolism. The high abundance of transcripts that encode desaturases and a lipoxygenase suggests that hexanoate may be formed through a pathway that involves the oxygenation and breakdown of unsaturated fatty acids.

1 February 1999 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
RGRoger Guevremont
Roger Guevremont
Randy PurvesRandy Purves
Randy Purves
The focusing of ions at atmospheric pressure and room temperature in a high-field asymmetric waveform ion mobility spectrometer (FAIMS) has been investigated. FAIMS operates with the application of a high-voltage, high-frequency asymmetric waveform across parallel plates. This establishes conditions wherein an ion migrates towards one of the plates because of a difference in the ion mobility at the low and high electric field conditions during application of the waveform. The migration can be stopped by applying a dc compensation voltage (CV) which serves to create a “balanced” condition wherein the ion experiences no net transverse motion. This method has also been called “transverse field compensation ion mobility spectrometry” and “field ion spectrometry®.” If this experiment is conducted using a device with cylindrical geometry, rather than with flat plates, an ion focusing region can exist in the annular space between the two concentric cylinders. Ion trajectory modeling showed that the behavior of the ions in the cylindrical geometry FAIMS analyzer was unlike any previously described atmospheric pressure ion optics system. The ions appeared to be trapped, or focused by being caught between two opposing forces. Requirements for establishing this focus for a given ion were identified: the applied waveform must be asymmetric, the electric field must be sufficiently high that the mobility of the ion deviates from its low-field value during the high-voltage portion of the asymmetric waveform, and finally, the electric field must be nonuniform in space (e.g., cylindrical or spherical geometry). Experimental observations with a prototype FAIMS device, which was designed to measure the radial distribution of ions in the FAIMS analyzer region, have confirmed the results of ion trajectory modeling.

1 September 2019 in Trends in Food Science & Technology
Verified
Journal Article
Open access
Hamid KhazaeiHamid Khazaei
Hamid Khazaei
Randy PurvesRandy Purves
Randy Purves
JHJessa Hughes
Jessa Hughes
WLWolfgang Link
Wolfgang Link
DODonal M. O'SUllivan
Donal M. O'SUllivan
FSFrederick L. Stoddard
Frederick L. Stoddard

1 August 2016 in Analytica Chimica Acta
Verified
Journal Article
Open access
JWJamie L. Willems
Jamie L. Willems
MKMona M. Khamis
Mona M. Khamis
WMWaleed A Mohammed-Saeid
Waleed A Mohammed-Saeid
Randy PurvesRandy Purves
Randy Purves
GKGeorge Katselis
George Katselis
AEAnas El-Aneed
Anas El-Aneed
Chlorogenic acids are among the most abundant phenolics found in the human diet. Of these, the mono-caffeoylquinic acids are the predominant phenolics found in fruits, such as apples and pears, and products derived from them. In this research, a comprehensive study of the electrospray ionization (ESI) tandem mass spectrometric (MS/MS) dissociation behavior of the three most common mono-caffeoylquinic acids, namely 5-O-caffeoylquinic acid (5-CQA), 3-O-caffeoylquinic acid (3-CQA) and 4-O-caffeoylquinic acid (4-CQA), were determined using both positive and negative ionization. All proposed structures of the observed product ions were confirmed with second-generation MS(3) experiments. Similarities and differences between the dissociation pathways in the positive and negative ion modes are discussed, confirming the proposed structures and the established MS/MS fingerprints. MS/MS dissociation was primarily driven via the cleavage of the ester bond linking the quinic acid moiety to the caffeic acid moiety within tested molecules. Despite being structural isomers with the same m/z values and dissociation behaviors, the MS/MS data in the negative ion mode was able to differentiate the three isomers based on ion intensity for the major product ions, observed at m/z 191, 179 and 173. This differentiation was consistent among various MS instruments. In addition, ESI coupled with high-field asymmetric waveform ion mobility spectrometry-mass spectrometry (ESI-FAIMS-MS) was employed for the separation of these compounds for the first time. By combining MS/MS data and differential ion mobility, a method for the separation and identification of mono-caffeoylquinic in apple/pear juice samples was developed with a run time of less than 1 min. It is envisaged that this methodology could be used to identify pure juices based on their chlorogenic acid profile (i.e., metabolomics), and could also be used to detect juice-to-juice adulteration (e.g., apple juice addition to pear juice).