Toru Yamada

Dr. Toru Yamada


Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TYToru Yamada
Toru Yamada
SUShinji Umeyama
Shinji Umeyama
KMKeiji Matsuda
Keiji Matsuda
In conventional functional near-infrared spectroscopy (fNIRS), systemic physiological fluctuations evoked by a body's motion and psychophysiological changes often contaminate fNIRS signals. We propose a novel method for separating functional and systemic signals based on their hemodynamic differences. Considering their physiological origins, we assumed a negative and positive linear relationship between oxy- and deoxyhemoglobin changes of functional and systemic signals, respectively. Their coefficients are determined by an empirical procedure. The proposed method was compared to conventional and multi-distance NIRS. The results were as follows: (1) Nonfunctional tasks evoked substantial oxyhemoglobin changes, and comparatively smaller deoxyhemoglobin changes, in the same direction by conventional NIRS. The systemic components estimated by the proposed method were similar to the above finding. The estimated functional components were very small. (2) During finger-tapping tasks, laterality in the functional component was more distinctive using our proposed method than that by conventional fNIRS. The systemic component indicated task-evoked changes, regardless of the finger used to perform the task. (3) For all tasks, the functional components were highly coincident with signals estimated by multi-distance NIRS. These results strongly suggest that the functional component obtained by the proposed method originates in the cerebral cortical layer. We believe that the proposed method could improve the reliability of fNIRS measurements without any modification in commercially available instruments.

1 January 2009 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
TYToru Yamada
Toru Yamada
SUShinji Umeyama
Shinji Umeyama
KMKeiji Matsuda
Keiji Matsuda
Functional near-infrared spectroscopy has the potential to easily detect cerebral functional hemodynamics. However, in practical fNIRS measurements, a subject’s physical or systemic physiological activities often cause undesirable artifacts. Such activities can be evoked even by task execution. In this case, observed artifacts may correlate strongly with the task sequence, and it is difficult to eliminate them by conventional signal filtering techniques. We present a theoretical analysis and Monte Carlo simulations of layered media in which both scattering and absorption changes occur, and show that a multidistance probe arrangement is effective in removing artifacts and extracting functional hemodynamics. The probe arrangement is determined based on simulation results. Artifacts induced by nonfunctional tasks (body tilting, head nodding, and breath holding) are clearly observed when a conventional method is used; such artifacts are appreciably reduced by the proposed method. Signals evoked by single-sided finger movements are observed at both hemispheres when we use a conventional method. On the other hand, localized signals at the primary motor area are observed by the proposed method. A statistically significant increase in oxygenated hemoglobin and decrease in deoxygenated hemoglobin are simultaneously observed at the contralateral primary motor area.

1 January 2009 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
SUShinji Umeyama
Shinji Umeyama
TYToru Yamada
Toru Yamada
The performance of near-infrared spectroscopy is sometimes degraded by the systemic physiological interference in the extracerebral layer. There is some systemic interference, which is highly correlated with the functional response evoked by a task execution. This kind of interference is difficult to remove by using ordinary techniques. A multidistance measurement method is one of the possible solutions for this problem. The multidistance measurement method requires estimation parameters derived from partial pathlength values of tissue layers to calculate an absorption coefficient change from a temporal absorbance change. Because partial path lengths are difficult to obtain, experimentally, we estimated them by a Monte Carlo simulation based on a five-layered slab model of a human adult head. Model parameters such as thickness and the transport scattering coefficient of each layer depend on a subject and a measurement position; thus, we assumed that these parameters obey normal distributions around standard parameter values. We determined the estimation parameters that provide a good separation performance in average for the model parameter distribution. The obtained weighting is robust to model parameter deviation and provides smaller errors on average compared to the parameters, which are determined without considering parameter distribution.

1 February 2020 in The Astrophysical Journal
Verified
Journal Article
Open access
KMKen Mawatari
Ken Mawatari
AIAkio K. Inoue
Akio K. Inoue
THTakuya Hashimoto
Takuya Hashimoto
JSJohn Silverman
John Silverman
MKMasaru Kajisawa
Masaru Kajisawa
TNTohru Nagao
Tohru Nagao
We search for galaxies with a strong Balmer break (Balmer break galaxies; BBGs) at z ∼ 6 over a 0.41 deg2 effective area in the COSMOS field. Based on rich imaging data, including data obtained with the Atacama Large Millimeter/submillimeter Array (ALMA), three candidates are identified by their extremely red K–[3.6] colors, as well as by nondetection in the X-ray, optical, far-infrared, and radio bands. The nondetection in the deep ALMA observations suggests that they are not dusty galaxies but BBGs at z ∼ 6, although contamination from active galactic nuclei at z ∼ 0 cannot be completely ruled out for the moment. Our spectral energy distribution analyses reveal that the BBG candidates at z ∼ 6 have stellar masses of ≈5 × 1010 M ⊙ dominated by old stellar populations with ages of ≳ 700 Myr. Assuming that all three candidates are real BBGs at z ∼ 6, we estimate the stellar mass density to be Mpc−3. This is consistent with an extrapolation from the lower-redshift measurements. The onset of star formation in the three BBG candidates is expected to be several hundred million yr before the observed epoch of z ∼ 6. We estimate the star formation rate density (SFRD) contributed by progenitors of the BBGs to be 2.4–12 × 10−5 M ⊙ yr−1 Mpc−3 at z > 14 (99.7% confidence range). Our result suggests a smooth evolution of the SFRD beyond z = 8.

2 November 2015 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
TYToru Yamada
Toru Yamada
SUShinji Umeyama
Shinji Umeyama
MOMitsuo Ohashi
Mitsuo Ohashi
Functional near-infrared spectroscopy (fNIRS) has been increasingly utilized for detecting human cerebral activity in many disciplines because of the potential for less-restraining conditions. However, users often suffer from motion artifacts originating from optode fluctuation during task execution when the task includes motion. In such cases, the optode fluctuation induces changes both in the reflection by hair and in the transmission between the optode and scalp. If part of the reflected light is directly received by the detector optode (short-circuited light), it will contaminate the fNIRS signal. The transmittance change at the optode–scalp gap will also contaminate the signal. In this study, we proposed an optical model on the influence of optode fluctuation on the fNIRS signal and a method for removing the influence. The model revealed the following: (1) the received short-circuited light and the gap transmittance change generated a baseline change in the detected light intensity, and (2) the signal from the tissues was downscaled with increases in the receiving intensity of short-circuited light. To avoid erroneous detection of short-circuited light, we developed a method that optically eliminated hair-reflected light from the detection using linearly polarized light sources and an orthogonally polarized analyzer. The method was validated with an optical phantom possessing a haired surface. The optical absorbance change of a close source–detector (S-D) pair equipped with polarizers was very similar to that of distant S-D pairs, even though these optodes were artificially fluctuated. By combining the multidistance optode arrangement technique with the short-circuited light elimination method, the measurement could effectively eliminate motion artifacts originating from optode fluctuation.

25 May 2017 in The Astrophysical Journal
Verified
Journal Article
Open access
PDF file
YJYoun Kil Jung
Youn Kil Jung
AUA. Udalski
A. Udalski
IBI. A. Bond
I. A. Bond
JYJennifer C. Yee
Jennifer C. Yee
AGAndrew Gould
Andrew Gould
AYA. Yonehara
A. Yonehara
We report the analysis of the first resolved caustic-crossing binary-source microlensing event OGLE-2016-BLG-1003. The event is densely covered by round-the-clock observations of three surveys. The light curve is characterized by two nested caustic-crossing features, which is unusual for typical caustic-crossing perturbations. From the modeling of the light curve, we find that the anomaly is produced by a binary source passing over a caustic formed by a binary lens. The result proves the importance of high-cadence and continuous observations, and the capability of second-generation microlensing experiments to identify such complex perturbations that are previously unknown. However, the result also raises the issues of the limitations of current analysis techniques for understanding lens systems beyond two masses and of determining the appropriate multiband observing strategy of survey experiments.