Surface-enhanced Raman spectroscopy (SERS) based on nanosilver colloid substrates has great potential for rapid detection of pesticide residues because of its advantages of sensitivity, rapidity, simplicity, low cost, etc. However, its poor repeatability and narrow linear quantitative range limit its practical application. In this paper, a silver colloid SERS analysis method combined with an exhaustive peak-seeking method was introduced for quantitative determination of thiram and ziram. This method can establish a linear quantitative relationship in a wide range by use of an own characteristic peak of analysis as an internal standard (IS) which is found via judging the linear correlation between the intensity ratios of two SERS peaks of analytes and the concentrations. Combined with improving the preparation method of silver colloids, adding suitable activators and optimizing the detection process, a liquid detection system with good repeatability and a wide linear quantitation range was obtained. The relative standard deviation (RSD) of the strongest SERS peak is no more than 8.98%, which is better than the general case of the silver colloid SERS substrate. The ratio of I1384/I1148 has a good linear relationship with the concentration of thiram solution, and the 1148 cm−1 characteristic peak was utilized as the IS to establish the standard curve equation for the determination of thiram concentration. The equation is I1384/I1148 = −1.7930 × lg[cthiram (ppm)] + 6.0078 with a linear range of 10−2 to 102 ppm (4.16 × 10−8 to 4.16 × 10−4 mol L−1) and a limit of detection (LOD) of 10−2 ppm. The peak of IS for the determination of ziram concentration is at 938 cm−1, and the equation is I1384/I938 = 4.5531 × lg[cziram (ppm)] + 6.4792 with a linear range of 10−1 to 102 ppm (3.27 × 10−7 to 3.27 × 10−4 mol L−1) and a LOD of 10−4 ppm. Thiram or ziram in apple juice was successfully detected by using this liquid detection system. This analysis system effectively solves the problem of poor repeatability and a narrow linear quantification range in SERS analysis based on silver colloid substrates, and the linear quantification range meets the requirements of the national standard (GB-2763-2019).
Perturbation-induced infrared spectroscopy combined with a deep learning-based chemical image identification method enables rapid and non-destructive identification of different samples with a quite similar composition and morphological complexity.
Attenuated total reflection (ATR) – Fourier transform infrared (FTIR) spectroscopy with the pretreatment of converting the absorption spectrum into angle spectrum (CASAS) and partial least squares (PLS) was employed to rapidly and simultaneously determine the ingredients of cellulose slurries and solutions during lyocell production. ATR was employed to rapidly and conveniently collect the spectra of the swollen slurries and viscous solutions during production. CASAS was used to eliminate the influence on modeling by the optical path differences due to uneven ingredient distributions in the samples. The PLS models for the cellulose, water, and N-methylmorpholine N-oxide (NMMO) concentrations of the cellulose slurry/solution were constructed using the raw spectra, pretreated spectra by CASAS, and common pretreatment methods, respectively. The results show that CASAS eliminates interferences due to the differences in optical path and improves the performance of PLS model for each analyte. The standard errors of prediction (SEP) of models using CASAS for cellulose, NMMO, and water concentration of cellulose slurry were 0.368, 0.196 and 0.171, while the values for the cellulose solution were 0.442, 0.353, and 0.066, respectively. The standard errors of prediction (SEPs) of CASAS models are significantly lower than the reproducibility requirement of the reference method, 0.5. The reported approach using ATR-FTIR spectroscopy combined with CASAS and PLS is rapid and accurate for determining the ingredients of the cellulose slurries and solutions and offers potential for identifying similar samples.
Melt flow rate (MFR) and vinyl acetate content (VAC) are the target parameters for quality control of poly(ethylene vinyl acetate) (EVA) pellets in production processes. Standard test methods for these two properties are too time consuming to meet the actual instant needs in industry. In order to solve this problem, an online near-infrared spectroscopy (NIR) system was integrated in this study to determine the MFR and VAC of EVA pellets in process. When collecting spectra, the difference of sample loading density and optical path will cause noise and decrease the spectral and prediction precision of quantitative models of the MFR and VAC. Although routine spectral pre-treatment methods, including the first order (1st) derivative and multiplicative scatter correction (MSC), are effective in reducing noise, the standard error of prediction (SEP) values of partial least squares (PLS) models of MFR and VAC using the pretreated spectra are still much larger than the reproducibility requirement of standard methods. The key aim of this present study is to explore a novel method based on angle transform to improve the online models. Before establishing models, the original spectra are transformed to angular spectra that reflect the composition information of the sample and are not influenced by the spectral intensity. This method can effectively reduce the severe noise and improve the performance of the models. The SEPs of PLS models of the MFR and VAC using angular spectra are 0.08 and 0.21, respectively. These two values are lower than the reproducibility requirement of standard test methods for the MFR, 0.1 and VAC, 0.3. A new online method of NIR spectroscopy combined with PLS using angular spectra has been successfully established to simultaneously determine the chemical and physical properties of EVA pellets. This research solves a tough technical problem existing in online NIR analysis of pellet samples carried by conveyor belts or pipelines with diffuse reflectance mode.