Daniel Milej

Dr. Daniel Milej

Imaging Division, Lawson Health Research Institute, London, ON, Canada
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2014 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Lorenzo SpinelliLorenzo Spinelli
Lorenzo Spinelli
MBM. Botwicz
M. Botwicz
NZN. Zolek
N. Zolek
MKM. Kacprzak
M. Kacprzak
Daniel MilejDaniel Milej
Daniel Milej
GZG. Zaccanti
G. Zaccanti
A multi-center study has been set up to accurately characterize the optical properties of diffusive liquid phantoms based on Intralipid and India ink at near-infrared (NIR) wavelengths. Nine research laboratories from six countries adopting different measurement techniques, instrumental set-ups, and data analysis methods determined at their best the optical properties and relative uncertainties of diffusive dilutions prepared with common samples of the two compounds. By exploiting a suitable statistical model, comprehensive reference values at three NIR wavelengths for the intrinsic absorption coefficient of India ink and the intrinsic reduced scattering coefficient of Intralipid-20% were determined with an uncertainty of about 2% or better, depending on the wavelength considered, and 1%, respectively. Even if in this study we focused on particular batches of India ink and Intralipid, the reference values determined here represent a solid and useful starting point for preparing diffusive liquid phantoms with accurately defined optical properties. Furthermore, due to the ready availability, low cost, long-term stability and batch-to-batch reproducibility of these compounds, they provide a unique fundamental tool for the calibration and performance assessment of diffuse optical spectroscopy instrumentation intended to be used in laboratory or clinical environment. Finally, the collaborative work presented here demonstrates that the accuracy level attained in this work for optical properties of diffusive phantoms is reliable.

1 August 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
HWHeidrun Wabnitz
Heidrun Wabnitz
DTDieter Richard Taubert
Dieter Richard Taubert
MMMikhail Mazurenka
Mikhail Mazurenka
OSOliver Steinkellner
Oliver Steinkellner
AJAlexander Jelzow
Alexander Jelzow
Alessandro TorricelliAlessandro Torricelli
Alessandro Torricelli
In recent years, instruments and methodologies to noninvasively probe human tissues by diffuse light in the near-infrared spectral range have undergone translation from laboratory bench to bedside. For example, clinical trials have been performed targeting the female breast. Optical mammography has been developed and applied to detect and characterize breast lesions,1,2 as well as to monitor the outcome of neoadjuvant chemotherapy of the breast.3,4 Diffuse optical spectroscopy is a promising technique for cancer risk assessment.5,6 In parallel, many clinical studies have been conducted targeting the brain. Optical imaging has been used to observe the hemodynamic response to cognitive, sensory, and motor stimuli,7 and to assess changes associated with traumatic brain injury,8 stroke,9 and epilepsy,10 with the aim of providing a less expensive and portable alternative to the existing neuroimaging techniques such as magnetic resonance imaging or x-ray computed tomography. Meanwhile, optical techniques have also been applied to other tissues such as muscle, joints, bone, and skin as a means of providing diagnostic information.

1 August 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
HWHeidrun Wabnitz
Heidrun Wabnitz
AJAlexander Jelzow
Alexander Jelzow
MMMikhail Mazurenka
Mikhail Mazurenka
OSOliver Steinkellner
Oliver Steinkellner
RMRainer Macdonald
Rainer Macdonald
APAntonio Pifferi
Antonio Pifferi
In biomedical optics, the characterization of instrumentation with the help of appropriate tissue-simulating phantoms1 plays an important role, ranging from proof-of-principle tests at early stages of the development to quality assurance during routine clinical application.2 Numerous performance studies have been carried out by individual research groups; however, there are only a few multilaboratory efforts to characterize and to compare multiple instruments. Such approaches are essential to provide a sound basis for achieving quantitatively comparable results in clinical studies. They require the development of standardized guidelines to perform the same measurements on phantoms with the same properties in different laboratories. In the field of photon migration instruments, the first systematic study of different instruments was performed on the basis of the MEDPHOT protocol.3 Recently, the development and testing of phantoms has been reported for quality assurance in a multicenter clinical trial to measure the response of breast tumors to neoadjuvant chemotherapy by means of diffuse optical spectroscopic imaging.4 In the context of fluorescence imaging of tissues, phantoms were developed to characterize and compare imaging systems and to train surgeons.5

18 June 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
AFAndrea Farina
Andrea Farina
Alessandro TorricelliAlessandro Torricelli
Alessandro Torricelli
IBIlaria Bargigia
Ilaria Bargigia
LSLorenzo Spinelli
Lorenzo Spinelli
RCRinaldo Cubeddu
Rinaldo Cubeddu
APAntonio Pifferi
Antonio Pifferi
The in-vivo optical properties of the human head are investigated in the 600–1100 nm range on different subjects using continuous wave and time domain diffuse optical spectroscopy. The work was performed in collaboration with different research groups and the different techniques were applied to the same subject. Data analysis was carried out using homogeneous and layered models and final results were also confirmed by Monte Carlo simulations. The depth sensitivity of each technique was investigated and related to the probed region of the cerebral tissue. This work, based on different validated instruments, is a contribution to fill the existing gap between the present knowledge and the actual in-vivo values of the head optical properties.

1 October 2016 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Open access
WWWojciech Weigl
Wojciech Weigl
Daniel MilejDaniel Milej
Daniel Milej
DJDariusz Janusek
Dariusz Janusek
SWStanisław Wojtkiewicz
Stanisław Wojtkiewicz
PSPiotr Sawosz
Piotr Sawosz
ALAdam Liebert
Adam Liebert
We present an overview of the wide range of potential applications of optical methods for monitoring traumatic brain injury. The MEDLINE database was electronically searched with the following search terms: “traumatic brain injury,” “head injury,” or “head trauma,” and “optical methods,” “NIRS,” “near-infrared spectroscopy,” “cerebral oxygenation,” or “cerebral oximetry.” Original reports concerning human subjects published from January 1980 to June 2015 in English were analyzed. Fifty-four studies met our inclusion criteria. Optical methods have been tested for detection of intracranial lesions, monitoring brain oxygenation, assessment of brain perfusion, and evaluation of cerebral autoregulation or intracellular metabolic processes in the brain. Some studies have also examined the applicability of optical methods during the recovery phase of traumatic brain injury . The limitations of currently available optical methods and promising directions of future development are described in this review. Considering the outstanding technical challenges, the limited number of patients studied, and the mixed results and opinions gathered from other reviews on this subject, we believe that optical methods must remain primarily research tools for the present. More studies are needed to gain confidence in the use of these techniques for neuromonitoring of traumatic brain injury patients.

7 October 2020 in Neurophotonics
Verified
Journal Article
Open access
Daniel MilejDaniel Milej
Daniel Milej
AAAndrou Abdalmalak
Androu Abdalmalak
ARAjay Rajaram
Ajay Rajaram
KLKeith St. Lawrence
Keith St. Lawrence
Significance: Near-infrared spectroscopy (NIRS) combined with diffuse correlation spectroscopy (DCS) provides a noninvasive approach for monitoring cerebral blood flow (CBF), oxygenation, and oxygen metabolism. However, these methods are vulnerable to signal contamination from the scalp. Our work evaluated methods of reducing the impact of this contamination using time-resolved (TR) NIRS and multidistance (MD) DCS. Aim: The magnitude of scalp contamination was evaluated by measuring the flow, oxygenation, and metabolic responses to a global hemodynamic challenge. Contamination was assessed by collecting data with and without impeding scalp blood flow. Approach: Experiments involved healthy participants. A pneumatic tourniquet was used to cause scalp ischemia, as confirmed by contrast-enhanced NIRS, and a computerized gas system to generate a hypercapnic challenge. Results: Comparing responses acquired with and without the tourniquet demonstrated that the TR-NIRS technique could reduce scalp contributions in hemodynamic signals up to 4 times (rSD = 3 cm) and 6 times (rSD = 4 cm). Similarly, blood flow responses from the scalp and brain could be separated by analyzing MD DCS data with a multilayer model. Using these techniques, there was no change in metabolism during hypercapnia, as expected, despite large increases in CBF and oxygenation. Conclusion: NIRS/DCS can accurately monitor CBF and metabolism with the appropriate enhancement to depth sensitivity, highlighting the potential of these techniques for neuromonitoring.