Guo Xia

Dr. Guo Xia

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Analytical Biochemistry
Verified
Journal Article
Closed access
GXGuo Xia
Guo Xia
JWJiangtao Wang
Jiangtao Wang
ZLZhijian Liu
Zhijian Liu
LBLihao Bai
Lihao Bai
LMLong Ma
Long Ma

6 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ZFZhiwei Feng
Zhiwei Feng
GXGuo Xia
Guo Xia
MLMr. Lu
Mr. Lu
XCXiaobo Cai
Xiaobo Cai
HCHao Cui
Hao Cui
MHMingyong Hu
Mingyong Hu
A unique method to design a high-throughput and high-resolution ultrathin Czerny–Turner (UTCT) spectrometer is proposed. This paper reveals an infrequent design process of spectrometers based on Coddington’s equations, which will lead us to develop a high-performance spectrometer from scratch. The spectrometer is composed of cylindrical elements except a planar grating. In the simulation design, spot radius is sub-pixel size, which means that almost all of the energy is collected by the detector. The spectral resolution is 0.4 nm at central wavelength and 0.75 nm at edge wavelength when the width of slit is chosen to be 25 μm and the groove density is 900 lines/mm.

18 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LMLong Ma
Long Ma
GXGuo Xia
Guo Xia
SJShiqun Jin
Shiqun Jin
BLBai Lihao
Bai Lihao
JWJiangtao Wang
Jiangtao Wang
XCXiaobo Cai
Xiaobo Cai
Refractive index resolution is an important indicator for a wavelength interrogation surface plasmon resonance sensor, which can be affected by signal-to-noise ratio. This paper investigates the impact of spectral signal-to-noise ratio on a surface plasmon resonance sensor. The effects of different spectral powers and noises are compared and verified through simulation and experiments. The results indicate that the optimal resonance wavelength is changed and the refractive index resolution can even be nearly twice as good when the spectral signal-to-noise ratio is increased. The optimal resonance wavelength can be found by changing the spectral power distribution or noise.

21 September 2022 in Photonics
Verified
Journal Article
Open access
PDF file
WSWenjie Shi
Wenjie Shi
LGLin Gao
Lin Gao
LZLong Zhang
Long Zhang
ZFZhiwei Feng
Zhiwei Feng
FFFan Fang
Fan Fang
GXGuo Xia
Guo Xia
In this study, we propose a method of evaluating the spectral resolution of crossed-asymmetric Czerny-Turner spectrometers by comparing the impact of different slit functions on the optical transfer function, and different slit widths, through simulation and experiments. The results show that, the Gaussian function is suitable for narrower slit widths, such as 25 μm, and the rectangle function or convolution of slit-scattering function with rectangle function is suitable for wider slit widths, such as 50 μm, 150 μm, and 200 μm. The proposed method can provide guidance in the evaluation of spectral resolution in the preliminary optical design process of spectrometers.

1 December 2018 in Optics & Laser Technology
Verified
Journal Article
Closed access
SJShiqun Jin
Shiqun Jin
JXJinyu Xing
Jinyu Xing
HPHu Penghao
Hu Penghao
MHMingyong Hu
Mingyong Hu
GXGuo Xia
Guo Xia

11 October 2022 in Optics Express
Verified
Journal Article
Closed access
GXGuo Xia
Guo Xia
LGLin Gao
Lin Gao
ZFZhi-Wei Feng
Zhi-Wei Feng
LZLong Zhang
Long Zhang
WSWen-Jie Shi
Wen-Jie Shi
YLYan-Duo Li
Yan-Duo Li
A novel integrated surface plasmon resonance (SPR) sensor that combines an optical waveguide platform and an ultra-thin spectrometer is proposed. The core of the proposed method is a special-shaped optical waveguide structure that employs a wedge-shaped incident surface, which changes the position of the total reflection of the incident light on the sagittal plane without affecting the direction of propagation on the tangential plane. The parameters of the sensing module with the integrated SPR sensor and spectrometer module were designed and optimized to achieve higher performance in a compact optical waveguide platform. An experimental system was built based on the theoretical model, and the spectral sensitivity of the system was analyzed before sample detection, and the results showed that the spectral resolution in the working range could reach 9.9 nm. The refractive index sensitivity of this novel SPR sensor was 3186 nm/RIU with good stability by detecting different concentrations of sodium chloride samples. This new structure does not require an external spectrometer, thereby enabling an increase in the compactness of the SPR sensing system. The proposed method can provide a novel idea for the miniaturization of SPR sensors.