Koichiro Kimura

Dr. Koichiro Kimura

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
MAMio Adachi
Mio Adachi
TFTomoyuki Fujioka
Tomoyuki Fujioka
MMMio Mori
Mio Mori
KKKazunori Kubota
Kazunori Kubota
YKYuka Kikuchi
Yuka Kikuchi
UTUkihide Tateishi
Ukihide Tateishi
We aimed to evaluate an artificial intelligence (AI) system that can detect and diagnose lesions of maximum intensity projection (MIP) in dynamic contrast-enhanced (DCE) breast magnetic resonance imaging (MRI). We retrospectively gathered MIPs of DCE breast MRI for training and validation data from 30 and 7 normal individuals, 49 and 20 benign cases, and 135 and 45 malignant cases, respectively. Breast lesions were indicated with a bounding box and labeled as benign or malignant by a radiologist, while the AI system was trained to detect and calculate possibilities of malignancy using RetinaNet. The AI system was analyzed using test sets of 13 normal, 20 benign, and 52 malignant cases. Four human readers also scored these test data with and without the assistance of the AI system for the possibility of a malignancy in each breast. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were 0.926, 0.828, and 0.925 for the AI system; 0.847, 0.841, and 0.884 for human readers without AI; and 0.889, 0.823, and 0.899 for human readers with AI using a cutoff value of 2%, respectively. The AI system showed better diagnostic performance compared to the human readers (p = 0.002), and because of the increased performance of human readers with the assistance of the AI system, the AUC of human readers was significantly higher with than without the AI system (p = 0.039). Our AI system showed a high performance ability in detecting and diagnosing lesions in MIPs of DCE breast MRI and increased the diagnostic performance of human readers.

19 August 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
TFTomoyuki Fujioka
Tomoyuki Fujioka
MTMarie Takahashi
Marie Takahashi
MMMio Mori
Mio Mori
JTJunichi Tsuchiya
Junichi Tsuchiya
EYEmi Yamaga
Emi Yamaga
UTUkihide Tateishi
Ukihide Tateishi
The purpose of this study was to use the Coronavirus Disease 2019 (COVID-19) Reporting and Data System (CO-RADS) to evaluate the chest computed tomography (CT) images of patients suspected of having COVID-19, and to investigate its diagnostic performance and interobserver agreement. The Dutch Radiological Society developed CO-RADS as a diagnostic indicator for assessing suspicion of lung involvement of COVID-19 on a scale of 1 (very low) to 5 (very high). We investigated retrospectively 154 adult patients with clinically suspected COVID-19, between April and June 2020, who underwent chest CT and reverse transcription-polymerase chain reaction (RT-PCR). The patients’ average age was 61.3 years (range, 21–93), 101 were male, and 76 were RT-PCR positive. Using CO-RADS, four radiologists evaluated the chest CT images. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated. Interobserver agreement was calculated using the intraclass correlation coefficient (ICC) by comparing the individual reader’s score to the median of the remaining three radiologists. The average sensitivity was 87.8% (range, 80.2–93.4%), specificity was 66.4% (range, 51.3–84.5%), and AUC was 0.859 (range, 0.847–0.881); there was no significant difference between the readers (p > 0.200). In 325 (52.8%) of 616 observations, there was absolute agreement among observers. The average ICC of readers was 0.840 (range, 0.800–0.874; p < 0.001). CO-RADS is a categorical taxonomic evaluation scheme for COVID-19 pneumonia, using chest CT images, that provides outstanding performance and from substantial to almost perfect interobserver agreement for predicting COVID-19.

15 October 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
KYken yamagiwa
ken yamagiwa
JTJunichi Tsuchiya
Junichi Tsuchiya
KYKota Yokoyama
Kota Yokoyama
RWRyosuke Watanabe
Ryosuke Watanabe
KKKoichiro Kimura
Koichiro Kimura
UTUkihide Tateishi
Ukihide Tateishi
Deep learning (DL) image quality improvement has been studied for application to 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). It is unclear, however, whether DL can increase the quality of images obtained with semiconductor-based PET/CT scanners. This study aimed to compare the quality of semiconductor-based PET/CT scanner images obtained by DL-based technology and conventional OSEM image with Gaussian postfilter. For DL-based data processing implementation, we used Advanced Intelligent Clear-IQ Engine (AiCE, Canon Medical Systems, Tochigi, Japan) and for OSEM images, Gaussian postfilter of 3 mm FWHM is used. Thirty patients who underwent semiconductor-based PET/CT scanner imaging between May 6, 2021, and May 19, 2021, were enrolled. We compared AiCE images and OSEM images and scored them for delineation, image noise, and overall image quality. We also measured standardized uptake values (SUVs) in tumors and healthy tissues and compared them between AiCE and OSEM. AiCE images scored significantly higher than OSEM images for delineation, image noise, and overall image quality. The Fleiss kappa value for the interobserver agreement was 0.57. Among the 21 SUV measurements in healthy organs, 11 (52.4%) measurements were significantly different between AiCE and OSEM images. More pathological lesions were detected in AiCE images as compared with OSEM images, with AiCE images showing higher SUVs for pathological lesions than OSEM images. AiCE can improve the quality of images acquired with semiconductor-based PET/CT scanners, including the noise level, contrast, and tumor detection capability.

8 April 2022 in Tomography
Verified
Journal Article
Open access
PDF file
KKKoichiro Kimura
Koichiro Kimura
TFTomoyuki Fujioka
Tomoyuki Fujioka
MMMio Mori
Mio Mori
TATakuya Adachi
Takuya Adachi
THTakumi Hiraishi
Takumi Hiraishi
UTUkihide Tateishi
Ukihide Tateishi
Routine CT examinations are crucial in colorectal cancer patients (CCPs); however, the high frequency of radiation exposure is a significant concern. This study investigated the radiation dose, image quality, and diagnostic performance of tin filter-based spectral shaping chest–abdominal–pelvic (CAP) CT for CCPs. We reviewed 44 CCPs who underwent single-phase enhanced tin-filtered 100 kV (TF100kV) and standard 120 kV (ST120kV) CAP CT on separate days. Radiation metrics including the volume CT dose index (CTDIvol), dose-length product (DLP), and effective dose (ED) were calculated for both protocols. Two radiologists assessed the presence of the following lesions: lung metastasis, liver metastasis, lymph node metastasis, peritoneal dissemination, and bone metastasis. The area under the receiver operating characteristic curve (AUC) was calculated for the diagnostic performance of each protocol. Radiation metrics of the TF100kV protocol were significantly lower than those of the ST120kV protocol (CDTIvol 1.60 ± 0.31 mGy vs. 14.4 ± 2.50, p < 0.0001; DLP 107.1 (95.9–125.5) mGy·cm vs. 996.7 (886.2–1144.3), p < 0.0001; ED 1.93 (1.73–2.26) mSv vs. 17.9 (16.0–20.6), p < 0.0001, respectively). TF100kV protocol achieved comparable diagnostic performance to that of the ST120kV protocol (AUC for lung metastasis: 1.00 vs. 0.94; liver metastasis: 0.88 vs. 0.83, respectively). TF100kV protocol could substantially reduce the radiation dose by 89% compared to that with the ST120kV protocol while maintaining good diagnostic performance in CCPs.

26 March 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
YUYusuke Uchida
Yusuke Uchida
SYSoichiro Yoshida
Soichiro Yoshida
YAYuki Arita
Yuki Arita
HSHiroki Shimoda
Hiroki Shimoda
KKKoichiro Kimura
Koichiro Kimura
Yasuhisa FujiiYasuhisa Fujii
Yasuhisa Fujii
Preoperative imaging differentiation between ChRCC and RO is difficult with conventional subjective evaluation, and the development of quantitative analysis is a clinical challenge. Forty-nine patients underwent partial or radical nephrectomy preceded by MRI and followed by pathological diagnosis with ChRCC or RO (ChRCC: n = 41, RO: n = 8). The whole-lesion volume of interest was set on apparent diffusion coefficient (ADC) maps of 1.5T-MRI. The importance of selected texture features (TFs) was evaluated, and diagnostic models were created using random forest (RF) analysis. The Mean Decrease Gini as calculated through RF analysis was the highest for mean_ADC_value. ChRCC had a significantly lower mean_ADC_value than RO (1.26 vs. 1.79 × 10−3 mm2/s, p < 0.0001). Feature selection by the Boruta method identified the first-quartile ADC value and GLZLM_HGZE as important features. ROC curve analysis showed that there was no significant difference in the classification performances between the mean_ADC_value-only model and the Boruta model (AUC: 0.954 vs. 0.969, p = 0.236). The mean ADC value had good predictive ability for the distinction between ChRCC and RO, comparable to that of the combination of TFs optimized for the evaluated cohort. The mean ADC value may be useful in distinguishing between ChRCC and RO.

11 January 2025 in Japanese Journal of Radiology
Verified
Journal Article
Open access
PDF file
KYKota Yokoyama
Kota Yokoyama
MMMitsuru Matsuki
Mitsuru Matsuki
TITakanori Isozaki
Takanori Isozaki
KIKimiteru Ito
Kimiteru Ito
TITomoki Imokawa
Tomoki Imokawa
UTUkihide Tateishi
Ukihide Tateishi
Adrenal diseases pose significant diagnostic challenges due to the wide range of neoplastic and non-neoplastic pathologies. Radiologists have a crucial role in diagnosing and managing these conditions by, leveraging advanced imaging techniques. This review discusses the vital role of computed tomography (CT), magnetic resonance imaging (MRI), and nuclear medicine in adrenal imaging, and focuses on morphological and functional evaluations. First, the anatomy and physiology of the adrenal glands are described, followed by a discussion on ectopic adrenocortical adenomas and how they develop. The concepts and imaging findings of congenital diseases, such as congenital adrenal hyperplasia (CAH), adrenal rest tumors, and adrenocortical nodular disease, considering recent updates to the WHO Classification of Tumours (5th ed.) terminology are highlighted. The diagnostic value of dynamic contrast-enhanced CT and chemical-shift MRI for identifying adrenocortical adenomas are emphasized, alongside the use of adrenocortical scintigraphy such as 131I-adosterol scintigraphy for diagnosing Cushing’s disease, Cushing’s syndrome (CS), subclinical CS, and ectopic adrenocorticotropic hormone-producing tumors. Systemic complications associated with CS, and the diagnosis and treatment of pheochromocytomas, paragangliomas (PPGLs), and neuroblastomas, will also be discussed focusing on 123I-metaiodobenzylguanidine (MIBG) imaging and 131I-MIBG therapy. Pitfalls in 123I-MIBG imaging and the increasing importance of diagnosing hereditary PPGLs due to increased genetic testing are also be discussed. Additionally, the broad differential diagnosis for adrenal masses—including malignancies like adrenal carcinoma, metastases, and malignant lymphoma, as well as benign conditions like myelolipoma and ganglioneuroma, and complications, such as adrenal hemorrhage, infarction, and infections—will be outlined. The goal of this review was to provide an overview of adrenal diseases that includes the most recent information for radiologists to stay updated on the latest imaging techniques and advancements that can ensure accurate diagnosis and effective management.