Casper Kunstmann-Olsen

Dr. Casper Kunstmann-Olsen

University of York
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Applied Catalysis B: Environment and Energy
Verified
Journal Article
Closed access
MCMichael Craven
Michael Craven
DXDong Xiao
Dong Xiao
Casper Kunstmann-OlsenCasper Kunstmann-Olsen
Casper Kunstmann-Olsen
EKElena F. Kozhevnikova
Elena F. Kozhevnikova
FBFrédéric Blanc
Frédéric Blanc
IKIvan V. Kozhevnikov
Ivan V. Kozhevnikov

1 June 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Casper Kunstmann-OlsenCasper Kunstmann-Olsen
Casper Kunstmann-Olsen
MHMartin Hanczyc
Martin Hanczyc
JHJames Hoyland
James Hoyland
SRSteen Rasmussen
Steen Rasmussen
HRHorst-Günter Rubahn
Horst-Günter Rubahn

18 April 2016 in Chemistry of Materials
Verified
Journal Article
Open access
Casper Kunstmann-OlsenCasper Kunstmann-Olsen
Casper Kunstmann-Olsen
DBDomagoj Belic
Domagoj Belic
DBDan F. Bradley
Dan F. Bradley
MGMarcin P. Grzelczak
Marcin P. Grzelczak
MBMathias Brust
Mathias Brust
The changes in interparticle spacing upon hydration and dehydration of drop-cast films of hydrophilic gold nanoparticles (GNP) have been measured in situ with nanometer resolution using WetSTEM and ESEM. These subtle variations correlate well with the corresponding changes in the optical spectra and perceived color as well as changes in the electrical conductivity of the films. AC impedance analysis allows us to differentiate between resistive and capacitive components and to evaluate how these depend on average particle spacing and the water content of the matrix, respectively. Thin films of this type are well-known structures used for development of sensors and diagnostics.

11 April 2023 in Advanced Optical Materials
Verified
Journal Article
Open access
SCSoraya Caixeiro
Soraya Caixeiro
Casper Kunstmann-OlsenCasper Kunstmann-Olsen
Casper Kunstmann-Olsen
MSMarcel Schubert
Marcel Schubert
JHJoseph Hill
Joseph Hill
IBIsla R. M. Barnard
Isla R. M. Barnard
MGMalte C. Gather
Malte C. Gather
Multiplexed, specific, and sensitive detection of antigens is critical for the rapid and accurate diagnosis of disease and the informed development of personalized treatment plans. Here, it is shown that polymer microsphere lasers can be used as photonic sensors to monitor and quantify direct surface binding of biomolecules via changes in the refractive index. The unique spectral signature of each individual laser can be used to find their size and effective refractive index which adds a new encoding dimension when compared to conventional fluorescent beads. Antibody‐functionalized microlasers selectively detect protein binding, as demonstrated for Immunoglobulin G and C‐reactive protein, and have the ability to resolve different stages of the multilayer surface modification. Moreover, by continuously monitoring single lasers, the possibility of real‐time monitoring of binding dynamics between antigens in solution phase and the immobilized antibodies is demonstrated. For multiplexed detection, the microlasers are employed in a flow cytometer configuration, with fast spectral detection and identification of microlasers with and without antigen binding. It is envisioned that by combining microlasers with well‐established surface modification chemistries and flow geometries, the multiplexing ability of microbead immunoassays can be strongly increased while also opening avenues for single‐cell profiling within heterogeneous cell populations.

8 December 2011 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
Casper Kunstmann-OlsenCasper Kunstmann-Olsen
Casper Kunstmann-Olsen
JHJames D. Hoyland
James D. Hoyland
Horst-Günter RubahnHorst-Günter Rubahn
Horst-Günter Rubahn

2 May 2025 in npj Biosensing
Verified
Journal Article
Open access
CGCameron Gilroy
Cameron Gilroy
CSCallum D. Silver
Callum D. Silver
Casper Kunstmann-OlsenCasper Kunstmann-Olsen
Casper Kunstmann-Olsen
LMLisa Miller
Lisa Miller
SJSteven Johnson
Steven Johnson
TKThomas F. Krauss
Thomas F. Krauss
The blood test is one of the most performed investigations in clinical practice, with samples typically analysed in a centralised laboratory. Many of these tests monitor routine conditions that would benefit from a point-of-care approach, reducing the burden on practitioners, patients and healthcare systems. Such a decentralised model requires the development of sophisticated, yet easy-to-use technology; however, platforms that combine high-performance with low-cost and simplicity remain scarce. Moreover, most research papers only address a subset of requirements and study specific aspects in isolation. A systems approach that considers the interplay between each element of the technology is clearly required to develop a coherent solution. Here, we present such a systems approach in the context of testing for C-reactive protein (CRP), a commonly requested test in clinical practise that indicates inflammation and is particularly relevant for monitoring patients with chronic diseases, e.g. those with rheumatoid arthritis or who are undergoing cancer therapy. The approach we take here features an entirely passive microfluidic cartridge for blood separation, integrated with a high-performance sensing platform which we have tested in a real-world context. The device is compatible with a handheld detection unit and is simple to use yet can accurately detect CRP levels at clinically relevant levels.