31 January 2017 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
QXQing Xiong
Qing Xiong
SJShengchang Ji
Shengchang Ji
LZLingyu Zhu
Lingyu Zhu
LZLipeng Zhong
Lipeng Zhong
YLYuan Liu
Yuan Liu
Because of lack of current zero, dc arc is hard to be extinguished, which has become the main reason causing faults in dc system. To find an effective method to detect dc arc faults is of great significance. In this paper, a method for detecting dc arc fault based on electromagnetic radiation signal is presented. A dc arc generating device is designed to simulate dc arc faults caused by loose connection in dc systems. A fourth-order Hilbert curve fractal antenna is adopted to detect the electromagnetic radiation signals of dc arc. The amplitude and spectrums of electromagnetic radiation signals measured under different circuit currents are analyzed. A photovoltaic (PV) system is constructed and the dc arc generated in that system is measured. The test results show that, under the present experimental condition, the electromagnetic radiation pulses have an obvious characteristic frequency, which are in a range of 39-41 MHz. The characteristic frequency of electromagnetic radiation of dc arc generated in PV system is around 39 MHz. Moreover, the characteristic frequency of dc arc is compared with that of switch operation. The dc arc has higher characteristic frequency and longer interval of each electromagnetic radiation pulse than those of the switch operation. The results indicate that the characteristic frequency of electromagnetic radiation signals can be used as the detection parameter of dc arc.

25 January 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QXQing Xiong
Qing Xiong
XFXianyong Feng
Xianyong Feng
AGAngelo L. Gattozzi
Angelo L. Gattozzi
XLXiaojun Liu
Xiaojun Liu
LZLinzi Zheng
Linzi Zheng
Robert HebnerRobert Hebner
Robert Hebner
Series arc faults can cause fire hazards in dc distribution systems. During a series arc fault, the line impedance usually increases rapidly and the arc current includes high-frequency components. To capture the arc-induced high-frequency signals, parallel capacitors are added to the circuit. The characteristics of the currents through these capacitors permit fault detection and localization. This paper determined that a Rogowski coil could be constructed with adequate bandwidth to cover the relevant frequency band of 1 kHz-1 MHz, found that the amplitude of the pulse and the difference in the integrated fast Fourier transform of the current signal are well correlated with the series fault, described experiments to demonstrate that, over the range tested, the two parameters are robust with respect to the pressure of the atmosphere in which the arc forms, the electrode material, the speed at which the electrodes separate to initiate the arc, the switch operation, the load-type and the load change, and demonstrated that within the well-known limits of traveling wave localization, such localization can be used based on the capacitor current pulse information after it has been validated by the spectrum analysis as a fault and not a spurious signal. The proposed approach was demonstrated in two low-voltage dc cable circuits.

11 June 2018 in IEEE Journal of Photovoltaics
Verified
Journal Article
Closed access
QXQing Xiong
Qing Xiong
XLXiaojun Liu
Xiaojun Liu
XFXianyong Feng
Xianyong Feng
AGAngelo L. Gattozzi
Angelo L. Gattozzi
YSYuhang Shi
Yuhang Shi
Robert HebnerRobert Hebner
Robert Hebner
Arc faults threaten the safe operation of photovoltaic (PV) systems. An arc fault detection and localization approach using parallel capacitors is proposed. A PV system has been analyzed and tested with five capacitors paralleled with the branches in the system. Series and parallel arc faults at nine locations have been tested in the system. When an arc occurred, current pulses were generated in the capacitors and their amplitudes and polarities were obtained through Hall current sensors. Discrete wavelet transformation was performed on the capacitor currents and the distributions of their amplitudes, frequency spectrums, and polarities are here reported. The results indicate that the distributions are unique under different fault types and locations, which could be used to detect and localize arc faults in PV systems. Moreover, the amplitudes of the capacitor currents can also help to localize a series arc fault within a PV string. Finally, the proposed approach is validated by a double-fault test.

1 August 2018 in Solar Energy
Verified
Journal Article
Closed access
QXQing Xiong
Qing Xiong
SJShengchang Ji
Shengchang Ji
XLXiaojun Liu
Xiaojun Liu
XFXianyong Feng
Xianyong Feng
FZFan Zhang
Fan Zhang
RHRobert E. Hebner
Robert E. Hebner

6 September 2018 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
QXQing Xiong
Qing Xiong
SJShengchang Ji
Shengchang Ji
XLXiaojun Liu
Xiaojun Liu
XLXining Li
Xining Li
LZLingyu Zhu
Lingyu Zhu
RHRobert E. Hebner
Robert E. Hebner
A dc arc fault can be a serious threat to the safe operation of a low-voltage dc system. Typically, a fair amount of electromagnetic radiation (EMR) accompanies the arcing process. To investigate the characteristics of EMR of the series dc arc fault, a fourth-order Hilbert fractal antenna is used to detect the EMR signals generated by the dc arc. The factors influencing the characteristics of EMR including electrode material, diameter, current, and pressure are considered. The amplitudes of the EMR pulses at the arc initiation moment are measured, and fast Fourier transform is used to analyze the characteristics of the frequency spectrums. The test results indicate that the amplitudes of the EMR pulses generated by stainless steel electrodes are higher than those generated by brass, copper, and aluminum electrodes. Furthermore, the trends of the amplitudes of the EMR pulses with increasing current are different for electrodes with different diameters. Finally, it is observed that the influence of the pressure is different for different electrode materials. The characteristic frequency band of the EMR pulses of the dc arcs generated under various test conditions is in a certain range (36-41 MHz), which can be used as a detecting characteristic parameter for the series dc arc.

15 June 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XFXianyong Feng
Xianyong Feng
QXQing Xiong
Qing Xiong
AGAngelo L. Gattozzi
Angelo L. Gattozzi
RHRobert E Hebner
Robert E Hebner
Medium voltage dc (MVDC) distribution is a promising solution for many applications such as transportation electrification, city centers, oil and gas platforms, and renewable energy collection systems. Compared to ac, a MVDC system can significantly improve power density, energy efficiency, and controllability. Weight and size of power equipment are limiting factors in transportation electrification, and cables usually take up a large space in a power system. A focus of this research is to investigate the potential of dc supply to reduce cable size without compromising cable service life. Since partial discharges (PD) in internal voids have been identified as a major source for power equipment premature failure, it is critical to understand PD mechanisms of medium voltage cables under both ac and dc, especially PD from internal void and delamination. This paper presents PD experimental data from medium voltage cables and test coupons to show that dc supply could be a more favorable condition for cables than ac.