Jung-Ik Ha

Prof. Dr. Jung-Ik Ha

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2003 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JJJi-Hoon Jang
Ji-Hoon Jang
SSSeung-Ki Sul
Seung-Ki Sul
JHJung-Ik Ha
Jung-Ik Ha
KIK. Ide
K. Ide
MSM. Sawamura
M. Sawamura
This paper presents a new sensorless control scheme of a surface-mounted permanent-magnet (SMPM) motor using high-frequency voltage signal injection method based on the high-frequency impedance difference. In the SMPM motor, due to the flux of the permanent magnet, the stator core around the q-axis winding is saturated. This makes the magnetic saliency in the motor. This magnetic saliency has the information about the rotor position. The high-frequency voltage signal is injected into the motor in order to detect the magnetic saliency and estimate the rotor position. In this paper, the relationship between the high-frequency voltages and high-frequency currents is developed using the voltage equations at the high frequency, and the high-frequency impedance characteristics are analyzed experimentally under various conditions. The proposed sensorless control scheme makes it possible to drive the SMPM motor in the low-speed region including zero speed, even under heavy load conditions. The experimental results verify the performance of the proposed sensorless algorithm.

1 January 1999 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
JHJung-Ik Ha
Jung-Ik Ha
SSSeung-Ki Sul
Seung-Ki Sul

13 August 2012 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SKSungmin Kim
Sungmin Kim
JHJung-Ik Ha
Jung-Ik Ha
SSSeung-Ki Sul
Seung-Ki Sul
The rotor position of an interior permanent-magnet synchronous machine (IPMSM) can be estimated without a position sensor by signal injection sensorless control at standstill and/or in very low speed rotating condition. In the signal injection sensorless control, however, the fundamental control performance is limited by the frequency of the injected signal, and no negligible acoustic noise is generated. If the frequency of the injected voltage signal would increase to pulsewidth modulation (PWM) switching frequency and if the switching frequency is near or above audible range, the dynamics of the sensorless control can be improved, and the acoustic noise can be remarkably reduced or totally eliminated. This paper describes how to extract the rotor position information of IPMSM using the voltage signal injection whose frequency is the same as the PWM switching frequency. Compared to the conventional heterodyning process, the proposed method is simple to implement and appropriate for PWM switching frequency signal injection. The high-frequency voltage signal can be injected in the stationary reference frame or in the estimated rotor reference frame. In this paper, the 5- and 16-kHz signal injections are proposed, implemented, and compared. The experimental results confirm the effectiveness of the proposed method.

3 April 2009 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JHJung-Ik Ha
Jung-Ik Ha
This paper presents a voltage injection method for reconstructing phase currents from current signals measured on single current-shunt circuits with cost-effective and high-performance configurations in the pulsewidth modulation (PWM) inverters that are used for digital appliances. This method involves the injection of voltage signals at the carrier frequency for reconstructing the phase currents in PWM inverters using a single current sensor in the DC-link. It uses minimum signals to reduce the voltage and current harmonics caused by the injected signals. The vector of the injected voltage is at a minimum distance from the original reference to ensure the measurement time in the reconstruction of the phase currents. An injection sequence control method is also proposed to avoid an abrupt change in the injection signals. A PWM scheme for splitting phase voltages is proposed to reduce any audible noise, especially in low-speed operation. The proposed method reconstructs the phase currents with signals from a single current sensor and minimizes the amplitude of the injected signals to reduce the harmonics at audible noise frequencies in the injection signals. Experimental results showed the effectiveness of the proposed method.

1 November 2016 in Desalination
Verified
Journal Article
Closed access
JKJunil Kang
Junil Kang
TKTaeyoung Kim
Taeyoung Kim
HSHojoon Shin
Hojoon Shin
JLJiho Lee
Jiho Lee
JHJung-Ik Ha
Jung-Ik Ha
JYJeyong Yoon
Jeyong Yoon

7 August 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JHJung-Ik Ha
Jung-Ik Ha
This paper presents a technique for predicting phase currents in vector-controlled pulsewidth-modulated (PWM) inverters using single dc-link current sensor. There is a limitation for current measurements in the inverters. The measurements are executed in the effective voltages, not in the zero voltage. The current measured in the dc-link and then reconstructed to the phase value is used as a feedback value for controlling an ac machine. Here, there is a difference between the reconstructed current and measured currents at the top or bottom of PWM carrier such as in the conventional inverters. It changes according to the reference voltages, load conditions, noises, and disturbances. Next, it can cause deterioration of the performance of current control by increasing ripples in currents and torque. This paper analyzes the difference in the drives of a permanent magnet synchronous motor and proposes a method for reducing it. The proposed method predicts the currents measured at the fixed sampling points from those measured in the dc-link and the PWM patterns of voltage outputs. It can reduce current ripples and the experimental results verify it. It is applicable to the vapor compression refrigeration process with the low-cost and high-performance feature.