Objectives: We tested whether the poor ability of pulse pressure variation to predict fluid responsiveness in cases of acute respiratory distress syndrome was related to low lung compliance. We also tested whether the changes in cardiac index induced by passive leg-raising and by an end-expiratory occlusion test were better than pulse pressure variation at predicting fluid responsiveness in acute respiratory distress syndrome patients. Design: Prospective study. Setting: Medical intensive care unit. Patients: We included 54 patients with circulatory shock (63 ± 13 yrs; Simplified Acute Physiology Score II, 63 ± 24). Twenty-seven patients had acute respiratory distress syndrome (compliance of the respiratory system, 22 ± 3 mL/cm H2O). In nonacute respiratory distress syndrome patients, the compliance of the respiratory system was 45 ± 9 mL/cm H2O. Measurements and Main Results: We measured the response of cardiac index (transpulmonary thermodilution) to fluid administration (500 mL saline). Before fluid administration, we recorded pulse pressure variation and the changes in pulse contour analysis-derived cardiac index induced by passive leg-raising and end-expiratory occlusion. Fluid increased cardiac index ≥15% (44% ± 39%) in 30 “responders.” Pulse pressure variation was significantly correlated with compliance of the respiratory system (r = .58), but not with tidal volume. The higher the compliance of the respiratory system, the better the prediction of fluid responsiveness by pulse pressure variation. A compliance of the respiratory system of 30 mL/cm H2O was the best cut-off for discriminating patients regarding the ability of pulse pressure variation to predict fluid responsiveness. If compliance of the respiratory system was >30 mL/cm H2O, then the area under the receiver-operating characteristics curve for predicting fluid responsiveness was not different for pulse pressure variation and the passive leg-raising and end-expiratory occlusion tests (0.98 ± 0.03, 0.91 ± 0.06, and 0.97 ± 0.03, respectively). By contrast, if compliance of the respiratory system was ≤30 mL/cm H2O, then the area under the receiver-operating characteristics curve was significantly lower for pulse pressure variation than for the passive leg-raising and end-expiratory occlusion tests (0.69 ± 0.10, 0.94 ± 0.05, and 0.93 ± 0.05, respectively). Conclusions: The ability of pulse pressure variation to predict fluid responsiveness was inversely related to compliance of the respiratory system. If compliance of the respiratory system was ≤30 mL/cm H2O, then pulse pressure variation became less accurate for predicting fluid responsiveness. However, the passive leg-raising and end-expiratory occlusion tests remained valuable in such cases.
We evaluated the ability of an infrared photoplethysmography arterial waveform (continuous non-invasive arterial pressure, CNAP) to estimate arterial pulse pressure variation (PPV). We compared the ability of non-invasive PPV to predict fluid responsiveness with invasive PPV, respiratory variation of pulse contour-derived stroke volume, and changes in cardiac index induced by passive leg raising (PLR) and end-expiratory occlusion (EEO) tests. We measured the responses of cardiac index (PiCCO) to 500 ml of saline in 47 critically ill patients with haemodynamic failure. Before fluid administration, we recorded non-invasive and invasive PPVs, stroke volume variation, and changes in cardiac index induced by PLR and by 15 s EEO. Logistic regressions were performed to investigate the advantage of combining invasive PPV, stroke volume variation, PLR, and EEO when predicting fluid responsiveness. In eight patients, CNAP could not record arterial pressure. In the 39 remaining patients, fluid increased cardiac index by ≥15% in 17 ‘responders’. Considering the 195 pairs of measurements, the bias (sd) between invasive and non-invasive PPVs was −0.6 (2.3)%. The areas under the receiver operating characteristic (ROC) curves for predicting fluid responsiveness were 0.89 (95% confidence interval, 0.78–1.01) for non-invasive PPV compared with 0.89 (0.77–1.01), 0.84 (0.70–0.96), 0.95 (0.88–1.03), and 0.97 (0.91–1.03) for invasive pulse pressure, stroke volume variations, PLR, and EEO tests (no significant difference). Combining multiple tests did not significantly improve the area under the ROC curves. Non-invasive assessment of PPV seems valuable in predicting fluid responsiveness.
1 April 2017 in Clinical Microbiology and Infection
Increasing numbers of pyelonephritis-associated uropathogenic Escherichia coli (UPEC) are exhibiting high resistance to antibiotic therapy. They include a particular clonal group, the CTX-M-15-producing O25b:H4-ST131 clone, which has been shown to have a high dissemination potential. Here we show that a representative isolate of this E. coli clone, referred to as TN03, has enhanced metabolic capacities, acts as a potent intestine- colonizing strain, and displays the typical features of UPEC strains. In a modified streptomycin-treated mouse model of intestinal colonization where streptomycin was stopped 5 days before inoculation, we show that TN03 outcompetes the commensal E. coli strains K-12 MG1655, IAI1, and ED1a at days 1 and 7. Using an experimental model of ascending UTI in C3H/HeN mice, we then show that TN03 colonized the urinary tract. One week after the transurethral inoculation of the TN03 isolates, the bacterial loads in the bladder and kidneys were significantly greater than those of two other UPEC strains (CFT073 and HT7) belonging to the same B2 phylogenetic group. The differences in bacterial loads did not seem to be directly linked to differences in the inflammatory response, since the intrarenal expression of chemokines and cytokines and the number of polymorphonuclear neutrophils attracted to the site of inflammation was the same in kidneys colonized by TN03, CFT073, or HT7. Lastly, we show that in vitro TN03 has a high maximum growth rate in both complex (Luria-Bertani and human urine) and minimum media. In conclusion, our findings indicate that TN03 is a potent UPEC strain that colonizes the intestinal tract and may persist in the kidneys of infected hosts.