Vincent Bourdin

Dr. Vincent Bourdin


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Solar Energy
Verified
Journal Article
Closed access
NLN. Lindsay
N. Lindsay
QLQ. Libois
Q. Libois
JBJ. Badosa
J. Badosa
AMA. Migan-Dubois
A. Migan-Dubois
VBVincent Bourdin
Vincent Bourdin

1 January 1993 in Chemical Engineering Science
Verified
Journal Article
Closed access
LSL.M. Sun
L.M. Sun
VBVincent Bourdin
Vincent Bourdin

1 June 2014 in Solar Energy Materials and Solar Cells
Verified
Journal Article
Closed access
PHP. Hoang
P. Hoang
VBVincent Bourdin
Vincent Bourdin
QLQ. Liu
Q. Liu
GCG. Caruso
G. Caruso
VAV. Archambault
V. Archambault

1 March 1996 in AIChE Journal
Verified
Journal Article
Closed access
PDF file
VBVincent Bourdin
Vincent Bourdin
PGPh. Grenier
Ph. Grenier
FMF. Meunier
F. Meunier
LSL. M. Sun
L. M. Sun

1 January 1996 in Adsorption
Verified
Journal Article
Closed access
PDF file
VBVincent Bourdin
Vincent Bourdin
AGAndreas Germanus
Andreas Germanus
PGPhilippe Grenier
Philippe Grenier
JKJörg Kärger
Jörg Kärger

1 May 1998 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
VBVincent Bourdin
Vincent Bourdin
PGP. G. Gray
P. G. Gray
PGPh. Grenier
Ph. Grenier
MTM. F. Terrier
M. F. Terrier
An apparatus has been built for kinetics measurement in adsorption processes. It consists of a variable volume chamber where the adsorbent sample is placed. During the adsorption process the pressure and the sample temperature are measured. The temperature is measured by infrared detection achieving fast, sensitive, and nonintrusive measurements. Two methods are used for adsorption kinetics measurement: the volume step and the thermal frequency response. In the volume step method the volume is suddenly reduced and the adsorption process occurs at constant volume. Due to the sorption heat released during adsorption, the adsorbed mass is closely related to the sample temperature. This method permits one to determine the relevant thermodynamic parameters of the system and the kinetics up to 20 ms. The different mass transfer modes may then be separated. The thermal frequency response (TFR) method consists of achieving a periodic volume of the chamber. The amplitude and phase lag of the temperature, taking the pressure function as a reference, may be used to measure with great accuracy very fast kinetics (up to 1 ms). Moreover, it permits the easy discrimination of surface barrier from Fickian diffusion. Finally it allows one to measure microporous and macroporous mass transfer in the same experiment. It is shown that substantial improvements are obtained with the TFR method compared with the pressure frequency response method which was, until now, the best macroscopic method. Moreover, the TFR method has produced results in good accordance with the microscopic pulsed field gradient-nuclear magnetic resonance method. Volume step and TFR methods are limited to low pressure (less than ∼4 kPa ) in consequence of nonisothermal gas compression. Experimental results are given to illustrate the possibilities of both methods.