Yiqing Wang

Dr. Yiqing Wang

State Key Laboratory of Materials-Oriented Chemical Engineering, College of Electrical Engineering and Control Science, Nanjing Tech University, Nanjing, 211816, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Yiqing WangYiqing Wang
Yiqing Wang
MYMin Yang
Min Yang
CWChuanjian wu
Chuanjian wu
PH sensors based on a nanostructured ion-sensitive field-effect transistor have characteristics such as fast response, high sensitivity and miniaturization, and they have been widely used in biomedicine, food detection and disease monitoring. However, their performance is affected by many factors, such as gate dielectric material, channel material and channel thickness. In order to obtain a pH sensor with high sensitivity and fast response, it is necessary to determine the appropriate equipment parameters, which have high processing cost and long production time. In this study, a nanostructured ion-sensitive field-effect transistor was developed based on the SILVACO technology computer-aided design (TCAD) simulator. Through experiments, we analyzed the effects of the gate dielectric material, channel material and channel thickness on the electrical characteristics of the nanostructured field-effect transistor. Based on simulation results, silicon nitride was selected as the gate dielectric layer, while indium oxide was chosen as the channel layer. The structure and parameters of the dual channel ion-sensitive field-effect transistor were determined and discussed in detail. Finally, according to the simulation results, a pH sensor based on the nanostructured ion-sensitive field-effect transistor was fabricated. The accuracy of simulation results was verified by measuring the output, transfer and pH characteristics of the device. The fabricated pH sensor had a subthreshold swing as low as 143.19 mV/dec and obtained an actual sensitivity of 88.125 mV/pH. In addition, we also tested the oxidation reaction of hydrogen peroxide catalyzed by horseradish peroxidase, and the sensitivity was up to 144.26 pA mol−1 L−1, verifying that the ion-sensitive field-effect transistor (ISFET) can be used to detect the pH of micro solution, and then combine the enzyme-linked assay to detect the concentration of protein, DNA, biochemical substances, biomarkers, etc.

15 August 2025 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
TWTing Wang
Ting Wang
TLTao Liu
Tao Liu
XZXinglong Zhu
Xinglong Zhu
MZMinghui Zhang
Minghui Zhang
JJJidong Jiang
Jidong Jiang
Yiqing WangYiqing Wang
Yiqing Wang

9 October 2023 in Current Research in Biotechnology
Verified
Journal Article
Open access
Yiqing WangYiqing Wang
Yiqing Wang
FWFei Wu
Fei Wu
XWXun Wang
Xun Wang
SDSong Ding
Song Ding
WZWei Zhang
Wei Zhang
YTYijun Tan
Yijun Tan

7 June 2024 in Talanta
Verified
Journal Article
Closed access
WZWei Zhang
Wei Zhang
JJJidong Jiang
Jidong Jiang
TLTao Liu
Tao Liu
XWXun Wang
Xun Wang
Yiqing WangYiqing Wang
Yiqing Wang
WJWanqin Jin
Wanqin Jin

3 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
CXChao Xue
Chao Xue
YZYinqiang Zhang
Yinqiang Zhang
SDSong Ding
Song Ding
SCSong Cheng
Song Cheng
Yiqing WangYiqing Wang
Yiqing Wang
Paint coated corrosion detection and evaluation is a big challenge for steel performance and structure health. Eddy current pulsed thermography (ECPT) technique is investigated because it can reflect the corrosion physical properties through paint coating by the infrared signal. This paper proposes skewness method, which presents the feature of temperature curve’s shape automatically, and compares it with principal component analysis (PCA), phase analysis, and kurtosis feature extraction methods for paint coated corrosion characterization and evaluation. The averaged skewness shows the best sensitivity for 0–6 months corrosion. The normalized second principal component (PC) presents good sensitivity and the best measurement scale for corroded time. Furthermore, the temperature curve analysis proves that the electrical conductivity dominates the induced heating and heat distribution. The corrosion height is utilized to explain why ECPT technique is valid within 10 months corroded time. ECPT technique is proved as a smart sensor system for paint coated corrosion detection and characterization.

31 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SYShilin Yang
Shilin Yang
CBCuimei Bo
Cuimei Bo
JLJun Li
Jun Li
QTQiang Tan
Qiang Tan
Yiqing WangYiqing Wang
Yiqing Wang
WJWanqin Jin
Wanqin Jin
Online glucose monitoring during the fermentation process is critical for evaluating the microbial metabolism state and reaction course, achieving precise process control for industrial efficiency enhancement. However, the fast, wide-range and highly accurate test technique always presents a challenge for state-of-the-art analytical instruments. In this work, we proposed an online glucose analysis system based on a homemade screen-printed enzymatic biosensor chip composed of Prussian blue nanocubes with a high sensitivity of 83.404 mA mM -1 cm -2 . To match the detection behavior of this chip, a specific signal conversion system was designed to realize the highly precise acquisition and treatment of nA-level currents by integrating hardware acquisition circuits and Kalman filtering algorithms. Focusing on the continuous change in glucose concentration during fermentation, an adaptive injection strategy for the sampling volume was proposed to achieve an ultrawide linear range from 1 g/L to 180 g/L. The results show that the online analytical system exhibits excellent detection performance with high accuracy and low relative error of detection (<2%) during the fermentation of sophorolipid and ethanol compared to high performance liquid chromatography and commercial analyzers.