Daniele Tognetto

Dr. Daniele Tognetto

Department of Medicine, Surgery and Health Sciences, University Eye Clinic of Trieste, 34100 Trieste, Italy

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2006 in Ophthalmology
Verified
Journal Article
Closed access
Daniele TognettoDaniele Tognetto
Daniele Tognetto
RGRosita Grandin
Rosita Grandin
GSGiorgia Sanguinetti
Giorgia Sanguinetti
DMDaniela Minutola
Daniela Minutola
Marta Di NicolaMarta Di Nicola
Marta Di Nicola
GRGiuseppe Ravalico
Giuseppe Ravalico

1 January 1996 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
GRGiuseppe Ravalico
Giuseppe Ravalico
Daniele TognettoDaniele Tognetto
Daniele Tognetto
MPMariaAntonietta Palomba
MariaAntonietta Palomba
PBPatrizia Busatto
Patrizia Busatto
FBFabio Baccara
Fabio Baccara
Posterior capsule opacification (PCO) after intraocular lens (IOL) implantation has a multifactored pathogenesis. Capsulorhexis and capsular bag implantation of a one-piece, biconvex poly(methyl methacrylate) (PMMA) IOL are likely to reduce the PCO incidence. This study was performed to determine whether an ideal capsulorhexis size able to reduce PCO incidence exists. A retrospective study of 107 patients who had extracapsular cataract extraction with capsulorhexis and capsular bag IOL implantation was carried out. The PCO site (central, paracentral, and peripheral) and degree (mild, moderate, and severe) were evaluated in relation to the capsulorhexis edge location relative to the IOL optic. Slitlamp biomicroscopy and photography and examination with a three-mirror Goldmann lens were performed. Patients were divided into three groups. Group 1: capsulorhexis free edge located on the IOL optic for 360 degrees; Group 2: capsulorhexis free edge located asymmetrically on and peripherally to the IOL optic; Group 3: capsulorhexis free edge located peripherally to IOL optic for 360 degrees. Each group was divided into two subgroups; one received polyHema IOLs and the second, PMMA IOLs. In Groups 1 and 2, the capsular transparency was higher than in Group 3 (P < .04). Central opacification percentage was lower in Group 1 than in Groups 2 and 3 (P < .04). No statistically significant differences between the polyHema and the PMMA subgroups were seen. Capsulorhexis with a slightly smaller diameter than the IOL optic appears to be better than a large-size capsulorhexis in reducing the incidence of PCO.

1 July 2002 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
Daniele TognettoDaniele Tognetto
Daniele Tognetto
LTLisa Toto
Lisa Toto
GSGiorgia Sanguinetti
Giorgia Sanguinetti
GRGiuseppe Ravalico
Giuseppe Ravalico
To evaluate the formation of glistenings in foldable intraocular lenses (IOLs) of various materials after cataract surgery. University Eye Clinic of Trieste, Trieste, Italy. In this prospective study, 273 patients were randomized to have implantation of 1 of 7 types of foldable IOLs in the capsular bag after phacoemulsification. The IOLs were the CeeOn Edge 911A (Pharmacia & Upjohn Co.), ACR6D (Corneal), AcrySof (Alcon), SI-40NB (AMO), Hydroview H60M (Storz), Sensar (AMO), and Stabibag (Ioltech). The presence of glistenings in the IOL optic was assessed by slitlamp evaluation 7, 30, 90, 180, 360, and 720 days after surgery. The glistenings were graded at each control. Glistenings were observed in all IOL groups. The percentage of patients with glistenings ranged from 40.0% to 67.5%, with the percentage increasing up to 90 days after surgery and then becoming stable in most groups. The AcrySof group had a continuous increase over time. The mean grade of glistenings increased up to 180 days after surgery and then became stable in most groups. The AcrySof and 911A groups had a continuous increase over time. Glistening formation was observed in 7 different foldable IOLs. The AcrySof group had a higher percentage and a greater density of glistenings.

1 April 1997 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
GRGiuseppe Ravalico
Giuseppe Ravalico
Daniele TognettoDaniele Tognetto
Daniele Tognetto
FBFabio Baccara
Fabio Baccara
ALAndrea Lovisato
Andrea Lovisato
To evaluate corneal endothelium morphology and function after phacoemulsification using different viscoelastics. Eye Clinic, University of Trieste, Italy. This prospective, randomized study included results of preoperative and postoperative (7, 30, and 90 days) examinations of 66 patients scheduled for phacoemulsification without ocular pathology; 8 patients were excluded. Patients were randomly assigned to one of four groups based on type of viscoelastic used: 1% sodium hyaluronate (Healon); 1.4% sodium hyaluronate (Healon GV); 4% sodium chondroitin sulfate-3% sodium hyaluronate (Viscoat); 2% hydroxypropyl methylcellulose (Hymecel). Mean cell density and cell size variation coefficient were determined by specular microscopy; central corneal thickness, by ultrasonic pachymetry; and endothelial permeability coefficient and active pump function, by anterior segment fluorophotometry. There were no significant differences in postoperative mean cell loss among the groups. The cell size variation coefficient was altered in all groups 7 days after surgery and was still impaired at 30 days in the Hymecel group. A significant increase in mean corneal thickness, endothelial permeability, and active pump function occurred in the Healon and Hymecel groups 7 days after surgery. These parameters were still altered 30 days after surgery in the Hymecel group. Endothelial functional alterations did not occur in the Healon GV or Viscoat group. Viscoat and Healon GV are effective in minimizing functional damage of endothelial structure in the early medium-term postoperative period.

1 July 1997 in Ophthalmology
Verified
Journal Article
Closed access
GRGiuseppe Ravalico
Giuseppe Ravalico
FBFabio Baccara
Fabio Baccara
ALAndrea Lovisato
Andrea Lovisato
Daniele TognettoDaniele Tognetto
Daniele Tognetto

1 September 1997 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
GRGiuseppe Ravalico
Giuseppe Ravalico
Daniele TognettoDaniele Tognetto
Daniele Tognetto
MPMaria Antonietta Palomba
Maria Antonietta Palomba
ALAndrea Lovisato
Andrea Lovisato
FBFabio Baccara
Fabio Baccara
To compare the morphology and function of the corneal endothelium in the early postoperative period after extracapsular cataract extraction (ECCE) and phacoemulsification. University Eye Clinic of Trieste, Italy. In this prospective, randomized study of patients scheduled for cataract surgery, 40 patients were divided into two groups of 20 patients each. Group 1 had ECCE and Group 2, phacoemulsification; both had capsular bag intraocular lens (IOL) implantation. Preoperatively and 7 and 30 days postoperatively, a complete ophthalmological examination, endothelial specular microscopy, ultrasonic pachymetry, and anterior segment fluorophotometry were done. Visual acuity, endothelial cell density, cell size variation coefficient, corneal thickness, endothelial permeability coefficient, and endothelial pump function were studied. Visual acuity was better 7 days after phacoemulsification than after ECCE, but no differences were observed after 30 days. No significant differences in postoperative loss of endothelial cells were found between the two groups. Coefficient of variation in size, corneal thickness, and endothelial permeability significantly increased in both groups 7 days postoperatively, but only in the ECCE group 30 days postoperatively; the differences between the two groups were statistically significant. Endothelial pump function significantly increased after 7 days in only the phacoemulsification group. Functional endothelial failure occurred in the early period after ECCE. Phacoemulsification seemed to minimize postoperative functional damage to the endothelium.