Moon Inder Singh

Dr. Moon Inder Singh

Thapar Institute of Engineering & Technology, Patiala
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
MSMoon Inder Singh
Moon Inder Singh
MSMandeep Singh
Mandeep Singh

30 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMoon Inder Singh
Moon Inder Singh
MSMandeep Singh
Mandeep Singh
The challenge to develop an affective Brain Computer Interface requires the understanding of emotions psychologically, physiologically as well as analytically. To make the analysis and classification of emotions possible, emotions have been represented in a two-dimensional or three-dimensional space represented by arousal and valence domains or arousal, valence and dominance domains, respectively. This paper presents the classification of emotions into four classes in an arousal–valence plane using the orthogonal nature of emotions. The average Event Related Potential (ERP) attributes and differential of average ERPs acquired from the frontal region of 24 subjects have been used to classify emotions into four classes. The attributes acquired from the frontal electrodes, viz., Fp1, Fp2, F3, F4, F8 and Fz, have been used for developing a classifier. The four-class subject-independent emotion classification results in the range of 67–83% have been obtained. Using three classifiers, a mid-range accuracy of 85% has been obtained, which is considerably better than existing studies on ERPs.

12 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Jaydeep PanchalJaydeep Panchal
Jaydeep Panchal
MSMoon Inder Singh
Moon Inder Singh
MSMandeep Singh
Mandeep Singh
KSKarmjit Singh Sandha
Karmjit Singh Sandha
This paper presents a novel, low-cost, portable impedance analyzer system designed for biopotential electrode evaluation and skin/electrode impedance measurement, critical for enhancing bioelectrical signal quality in healthcare applications. In contrast with conventional systems that depend on external PCs or host devices for data acquisition, visualization, and analysis, this design integrates all functionalities into a single, compact platform powered by the Analog Devices AD5933 impedance converter and a Raspberry Pi 4. The design incorporates custom analog circuitry to extend the measurement range from 10 Hz to 100 kHz and supports a wide impedance spectrum through switchable feedback resistors. Validated against a benchtop impedance analyzer, the system demonstrates high accuracy with normalized root-mean-square errors (NRMSEs) of 1.41% and 3.77% for the impedance magnitude and phase of passive components, respectively, and 1.43% and 1.29% for the biopotential electrode evaluation and skin/electrode impedance measurement. This cost-effective solution, with a total cost of USD 159, addresses the accessibility challenges faced by smaller research labs and healthcare facilities, offering a compact, low-power platform for reliable impedance analysis in biomedical applications.

11 December 2015 in Transactions of the Institute of Measurement and Control
Verified
Journal Article
Closed access
PDF file
MSMoon Inder Singh
Moon Inder Singh
MSMandeep Singh
Mandeep Singh
The study of changes in physiological signals for emotion recognition in human subjects has generated immense interest in medical instrumentation. One of the effective ways of classifying emotions is by the use of the event-related potentials (ERPs) of electroencephalogram (EEG) signals. This requires projection of an image on one computer system while simultaneously putting a marker on another computer system acquiring the EEG. This is achieved using costly modules to synchronize the stimulus presentation system with the data acquisition system. This paper describes an innovative low-cost technique to achieve this simultaneous triggering on the second computer system using the parallel operation of mechanical keyboards. The latency aspect of both USB and PS/2 keyboards with their two keys galvanically connected have been experimentally analysed and compared. It has been found experimentally that the USB keyboards, if used in cognition research, would give better latency results compared with the PS/2 keyboards. The synchronization error between the two USB keyboards has been found to be lower than or equal to 1 ms for the maximum number of keystrokes. The horizon of applications of this technique is unlimited and it can be used in almost every sphere of cognition enhancement and research, where a perfect synchronization of the brain stimulus with the corresponding physiological signals being acquired is required.

3 March 2020 in Transactions of the Institute of Measurement and Control
Verified
Journal Article
Closed access
PDF file
MSMoon Inder Singh
Moon Inder Singh
MSMandeep Singh
Mandeep Singh
Analysis and study of abstract human relations have always posed a daunting challenge for technocrats engaged in the field of psychometric analysis. The study on emotion recognition is all the more demanding as it involves integration of abstract phenomenon of emotion causation and emotion appraisal through physiological and brain signals. This paper describes the classification of human emotions into four classes, namely: low valence high arousal (LVHA), high valence high arousal (HVHA), high valence low arousal (HVLA) and low valence low arousal (LVLA) using Electroencephalogram (EEG) signals. The EEG signals have been collected on three EEG electrodes along the central line viz: Fz, Cz and Pz. The analysis has been done on average event related potentials (ERPs) and difference of average ERPs using Support Vector Machine (SVM) polynomial classifier. The four-class classification accuracy of 75% using average ERP attributes and an accuracy of 76.8% using difference of ERPs as attributes has been obtained. The accuracy obtained using differential average ERP attributes is better as compared with the already existing studies.

20 December 2021 in Metrology and Measurement Systems
Verified
Journal Article
Closed access
PDF file
MSMoon Inder Singh
Moon Inder Singh
MSMandeep Singh
Mandeep Singh