Sven Månsson

Prof. Dr. Sven Månsson

Lund University, Department of Medical Radiation Physics
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2003 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
KGKlaes Golman
Klaes Golman
Jan Henrik Ardenkjaer-LarsenJan Henrik Ardenkjaer-Larsen
Jan Henrik Ardenkjaer-Larsen
JPJ. Stefan Petersson
J. Stefan Petersson
Sven MånssonSven Månsson
Sven Månsson
ILIb Leunbach
Ib Leunbach
Dynamic nuclear polarization has enabled hyperpolarization of nuclei such as 13 C and 15 N in endogenous substances. The resulting high nuclear polarization makes it possible to perform subsecond 13 C MRI. By using the dynamic nuclear polarization hyperpolarization technique, 10% polarization was obtained in an aqueous solution of 100 mM 13 C-labeled urea, ready for injection. The in vivo T 1 relaxation time of 13 C in the urea solution was determined to 20 ± 2 s. Due to the long relaxation time, it is possible to use the hyperpolarized substance for medical imaging. A series of high-resolution (≈1-mm) magnetic resonance images were acquired, each with a scan time of 240 ms, 0-5 s after an i.v. injection of the hyperpolarized aqueous [ 13 C]urea solution in a rat. The results show that it is possible to perform 13 C angiography with a signal-to-noise ratio of ≈275 in ≈0.25 s. Perfusion studies with endogenous substances may allow higher spatial and/or temporal resolution than is possible with current proton imaging techniques.

2 July 2001 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
KGK. Golman
K. Golman
OAO. Axelsson
O. Axelsson
HJH. Jóhannesson
H. Jóhannesson
Sven MånssonSven Månsson
Sven Månsson
COC. Olofsson
C. Olofsson
JPJ.S. Petersson
J.S. Petersson
High nuclear spin polarization of 13C was reached in organic molecules. Enhancements of up to 104, compared to thermal polarization at 1.5 T, were achieved using the parahydrogen‐induced polarization technique in combination with a field cycling method. While parahydrogen has no net polarization, it has a high spin order, which is retained when hydrogen is incorporated into another molecule by a chemical reaction. By subjecting this molecule to a sudden change of the external magnetic field, the spin order is transferred into net polarization. A 13C angiogram of an animal was generated in less than a second. Magn Reson Med 46:1–5, 2001.

21 April 2008 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
KGKlaes Golman
Klaes Golman
JPJ. Stefan Petersson
J. Stefan Petersson
PMPeter Magnusson
Peter Magnusson
EJEdvin Johansson
Edvin Johansson
PÅPer Åkeson
Per Åkeson
Sven MånssonSven Månsson
Sven Månsson
Pyruvate is included in the energy production of the heart muscle and is metabolized into lactate, alanine, and CO2 in equilibrium with HCO. The aim of this study was to evaluate the feasibility of using 13C hyperpolarization enhanced MRI to monitor pyruvate metabolism in the heart during an ischemic episode. The left circumflex artery of pigs (4 months, male, 29–34 kg) was occluded for 15 or 45 min followed by 2 hr of reperfusion. Pigs were examined by 13C chemical shift imaging following intravenous injection of 1‐13C pyruvate. 13C chemical shift MR imaging was used in order to visualize the local concentrations of the metabolites. After a 15‐min occlusion (no infarct) the bicarbonate signal level in the affected area was reduced (25–44%) compared with the normal myocardium. Alanine signal level was normal. After a 45‐min occlusion (infarction) the bicarbonate signal was almost absent (0.2–11%) and the alanine signal was reduced (27–51%). Due to image‐folding artifacts the data obtained for lactate were inconclusive. These studies demonstrate that cardiac metabolic imaging with hyperpolarized 1‐13C‐pyruvate is feasible. The changes in concentrations of the metabolites within a minute after injection can be detected and metabolic maps constructed. Magn Reson Med 59:1005–1013, 2008.

14 June 2005 in European Radiology
Verified
Journal Article
Closed access
PDF file
Sven MånssonSven Månsson
Sven Månsson
EJEdvin Johansson
Edvin Johansson
PMPeter Magnusson
Peter Magnusson
CCChun-Ming Chai
Chun-Ming Chai
GHGeorg Hansson
Georg Hansson
KGKlaes Golman
Klaes Golman

21 November 2003 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
Sven MånssonSven Månsson
Sven Månsson
JWJan Wolber
Jan Wolber
BDBastiaan Driehuys
Bastiaan Driehuys
PWPer Wollmer
Per Wollmer
KGKlaes Golman
Klaes Golman
The ability to quantify pulmonary diffusing capacity and perfusion using dynamic hyperpolarized 129Xe NMR spectroscopy is demonstrated. A model of alveolar gas exchange was developed, which, in conjunction with 129Xe NMR, enables quantification of average alveolar wall thickness, pulmonary perfusion, capillary diffusion length, and mean transit time. The technique was employed to compare a group of naïve rats (n = 10) with a group of rats with acute inflammatory lung injury (n = 10), caused by instillation of lipopolysaccaride (LPS). The measured structural and perfusion‐related parameters were in agreement with reported values from studies using non‐NMR methods. Significant differences between the groups were found in total diffusion length (control 8.5 ± 0.5 μm, LPS 9.9 ± 0.6 μm, P < 0.001), in capillary diffusion length (control 2.9 ± 0.4 μm, LPS 3.9 ± 1.0 μm, P < 0.05), and in pulmonary hematocrit (control 0.55 ± 0.06, LPS 0.43 ± 0.08, P < 0.01), whereas no differences were observed in alveolar wall thickness, pulmonary perfusion, and mean transit time. These results demonstrate the ability of the method to distinguish two main aspects of lung function, namely, diffusing capacity and pulmonary perfusion. Magn Reson Med 50:1170–1179, 2003.

25 February 2004 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
EJE. Johansson
E. Johansson
Sven MånssonSven Månsson
Sven Månsson
RWR. Wirestam
R. Wirestam
JSJ. Svensson
J. Svensson
JPJ.S. Petersson
J.S. Petersson
FSF. Ståhlberg
F. Ståhlberg
Cerebral perfusion was assessed with 13C MRI in a rat model after intravenous injections of the 13C‐labeled compound bis‐1,1‐(hydroxymethyl)‐1‐13C‐cyclopropane‐D8 in aqueous solutions hyperpolarized by dynamic nuclear polarization (DNP). Since the tracer acted as a direct signal source, several of the problems associated with techniques based on traditional dynamic susceptibility contrast (DSC) MRI contrast agents were avoided. Maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) were calculated. The MTT was determined to be 2.8 ± 0.8 sec. However, arterial partial‐volume effects in the animal model prevented accurate absolute quantification of CBF and CBV. It was demonstrated that depolarization of the hyperpolarized 13C tracer via relaxation and the imaging sequence had little influence on CBF assessment when the time resolution of the imaging sequence was short compared to the MTT. However, CBV and MTT were increasingly underestimated as MTT or the depolarization rate increased if depolarization was not taken into account. With a modified bolus‐tracking theory depolarization could be compensated for, assuming that the depolarization rate was known. Three separate compensation methods were investigated experimentally and by numerical simulations. Magn Reson Med 51:464–472, 2004.