Yinan Hu

Mr. Yinan Hu

The Helmholtz Institute Mainz

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 July 2022 in Science Advances
Verified
Journal Article
Open access
EDErik T. Van Dyke
Erik T. Van Dyke
JEJames Eills
James Eills
RPRomán Picazo-Frutos
Román Picazo-Frutos
KSKirill F. Sheberstov
Kirill F. Sheberstov
Yinan HuYinan Hu
Yinan Hu
DBDanila Barskiy
Danila Barskiy
Zero- to ultralow-field nuclear magnetic resonance (ZULF NMR) is a rapidly developing form of spectroscopy that provides rich spectroscopic information in the absence of large magnetic fields. However, signal acquisition still requires a mechanism for generating a bulk magnetic moment for detection, and the currently used methods only apply to a limited pool of chemicals or come at prohibitively high cost. We demonstrate that the parahydrogen-based SABRE (signal amplification by reversible exchange)–Relay method can be used as a more general means of generating hyperpolarized analytes for ZULF NMR by observing zero-field J -spectra of [ 13 C]-methanol, [1- 13 C]-ethanol, and [2- 13 C]-ethanol in both 13 C-isotopically enriched and natural abundance samples. We explore the magnetic field dependence of the SABRE-Relay efficiency and show the existence of a second maximum at 19.0 ± 0.3 mT. Despite presence of water, SABRE-Relay is used to hyperpolarize ethanol extracted from a store-bought sample of vodka (% P H ~ 0.1%).

30 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XZXue Zhang
Xue Zhang
GCGeorgios Chatzidrosos
Georgios Chatzidrosos
Yinan HuYinan Hu
Yinan Hu
HZHuijie Zheng
Huijie Zheng
Arne WickenbrockArne Wickenbrock
Arne Wickenbrock
Dmitry BudkerDmitry Budker
Dmitry Budker
Sensitive and accurate diagnostic technologies with magnetic sensors are of great importance for identifying and localizing defects of rechargeable solid batteries using noninvasive detection. We demonstrate a microwave-free alternating current (AC) magnetometry method with negatively charged NV centers in diamond based on a cross-relaxation feature between nitrogen-vacancy (NV) centers and individual substitutional nitrogen (P1) centers occurring at 51.2 mT. We apply the technique to non-destructively image solid-state batteries. By detecting the eddy-current-induced magnetic field of the battery, we distinguish a defect on the external electrode and identify structural anomalies within the battery body. The achieved spatial resolution is μμμ360μm. The maximum magnetic field and phase shift generated by the battery at the modulation frequency of 5 kHz are estimated as 0.04 mT and 0.03 rad respectively.

6 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Yinan HuYinan Hu
Yinan Hu
GIGeoffrey Z. Iwata
Geoffrey Z. Iwata
LBLykourgos Bougas
Lykourgos Bougas
JBJohn W. Blanchard
John W. Blanchard
Arne WickenbrockArne Wickenbrock
Arne Wickenbrock
Dmitry BudkerDmitry Budker
Dmitry Budker
Solid-state battery technology is motivated by the desire to deliver flexible power storage in a safe and efficient manner. The increasingly widespread use of batteries from mass production facilities highlights the need for a rapid and sensitive diagnostic tool for identifying battery defects. We demonstrate the use of atomic magnetometry to measure the magnetic fields around miniature solid-state battery cells. These fields encode information about battery manufacturing defects, state of charge, and impurities, and they can provide important insights into battery aging processes. Compared with SQUID-based magnetometry, the availability of atomic magnetometers, however, highlights the possibility of constructing a low-cost, portable, and flexible implementation of battery quality control and characterization technology.

15 August 2022 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
GIGeoffrey Z. Iwata
Geoffrey Z. Iwata
Yinan HuYinan Hu
Yinan Hu
AWArne Wickenbrock
Arne Wickenbrock
TSTilmann Sander
Tilmann Sander
Muthuraman MuthuramanMuthuraman Muthuraman
Muthuraman Muthuraman
DBDmitry Budker
Dmitry Budker
Transcranial magnetic stimulation (TMS) has widespread clinical applications from diagnosis to treatment. We combined TMS with non-contact magnetic detection of TMS-evoked muscle activity in peripheral limbs to explore a new diagnostic modality that enhances the utility of TMS as a clinical tool by leveraging technological advances in magnetometry. We recorded measurements in a regular hospital room using an array of optically pumped magnetometers (OPMs) inside a portable shield that encloses only the forearm and hand of the subject. We present magnetomyograms (MMG)s of TMS-evoked movement in a human hand, together with a simultaneous surface electromyograph (EMG) data. The biomagnetic signals recorded in the MMG provides detailed spatial and temporal information that is complementary to that of the electric signal channels. Moreover, we identify features in the magnetic recording beyond that of the EMG. This system demonstrates the value of biomagnetic signals in TMS-based clinical approaches and widens its availability and practical potential.

1 October 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
TPTonghui Peng
Tonghui Peng
WGWei Gao
Wei Gao
YWYa Wu
Ya Wu
YMYulong Ma
Yulong Ma
SZShiwu Zhang
Shiwu Zhang
Yinan HuYinan Hu
Yinan Hu
With the wide application of electric energy storage component arrays, such as battery cell arrays, capacitor arrays, and inductor arrays, their potential safety risks have gradually drawn the public attention. However, existing technologies cannot realize rapid, precise, and nondestructive localization of the faulty component within these large-scale arrays, especially for a component with an early stage short-circuit fault. To address this challenge, this paper proposes a magnetic field based method and realizes precise fault localization by inducing an alternating magnetic field from the target array, unlike previous research where a static magnetic field was induced. Through establishing a physical model of the short-circuit component as well as the whole array, a spatial filtering algorithm based on beamforming techniques is utilized to process the measured magnetic field data in real time. Both the simulation and experimental results demonstrate the capability of the proposed method in enhancing the security of electric energy storage component arrays. Within an imaging area of 80 × 80 mm2, the proposed method can accurately locate the faulty component out of a nine-component array, with an error of only 0.72 mm for capacitors and 0.91 mm for battery cells.

19 May 2020 in arXiv
Verified
Preprint
Open access
PDF file
GIGeoffrey Z. Iwata
Geoffrey Z. Iwata
Yinan HuYinan Hu
Yinan Hu
TSTilmann Sander
Tilmann Sander
Muthuraman MuthuramanMuthuraman Muthuraman
Muthuraman Muthuraman
VCVenkata Chaitanya Chirumamilla
Venkata Chaitanya Chirumamilla
AWArne Wickenbrock
Arne Wickenbrock
Objective: We present magnetomyograms (MMG) of TMS-evoked movement in a human hand, together with a simultaneous surface electromyograph (EMG) and electroencephalograph (EEG) data. Approach: We combined TMS with non-contact magnetic detection of TMS-evoked muscle activity in peripheral limbs to explore a new diagnostic modality that enhances the utility of TMS as a clinical tool by leveraging technological advances in magnetometry. We recorded measurements in a regular hospital room using an array of optically pumped magnetometers (OPM) inside a portable shield that encompasses only the forearm and hand of the subject. Main Results: The biomagnetic signals recorded in the MMG provide detailed spatial and temporal information that is complementary to that of the electric signal channels. Moreover, we identify features in the magnetic recording beyond those of the EMG. Significance: These results validate the viability of MMG recording with a compact OPM based setup in small-sized magnetic shielding, and provide proof-of-principle for a non-contact data channel for detection and analysis of TMS-evoked muscle activity from peripheral limbs.