This is a seven-year study (1/7/2011-31/12/2017) of radon monitoring at two sites of Campi Flegrei caldera (Neaples, Southern Italy) that in the last 70 years experienced repeated phases of volcanic unrest. The sites are equipped with devices for radon detection, based on the spectrometry analysis of the α-particles of radon daughters. A hybrid method, as combination of three known methods, is applied for the identification of residuals (anomalies) and trends of the time series of Radon. The results are compared with the following indicators of current caldera unrest: the tremor caused by the major fumarolic vent registered by a seismic station; the cumulative of background seismicity; the maximum vertical deformation acquired by GPS networks during the current phase of uplift; the temperature-pressure of the hydrothermal system estimated based on gas geo-indicators. The comparisons show strong correlation among independent signals and suggest that the extension of the area affected by current Campi Flegrei crisis is larger than the area of seismicity and of intense hydrothermal activity from which the radon stations are 1–4 km away. These results represent an absolute novelty in the study of a such calderic area and mark a significant step forward in the use and interpretation of the radon signal.
1 February 2021 in Journal of Environmental Radioactivity
This work concerns continuous monitoring of radon and thoron specific activity in soil gas within the framework of identifying possible anomalies. It is based on the analysis of a medium-term data record obtained from soil gas in an area of geophysical interest. The RaMonA spectrometric system is also used to measure the climatic parameters and a specific analysis of the alpha spectra is performed to better determine the alpha lines intensity. Since radon emission is also influenced by meteorological parameters, it is mandatory to differentiate the changes due to the deep phenomena. Different procedures are utilized to reach the above objective: statistical analysis using the Empirical Mode Decomposition technique, the Multiple Linear Regression method and the Remote Radon Estimation by using of the thoron trend to eliminate the locally produced radon fraction. The results of such methods are compared to recognize and to highlight radon anomalies.
222Rn gas represents the major contributor to human health risk from environmental radiological exposure. In confined spaces radon can accumulate to relatively high levels so that mitigation actions are necessary. The Italian legislation on radiation protection has set a reference value for the activity concentration of radon at 300 Bq/m3. In this study, measurements of the annual radon concentration of 62 bank buildings spread throughout the Campania region (Southern Italy) were carried out. Using devices based on CR-39 solid-state nuclear track detectors, the 222Rn level was assessed in 136 confined spaces (127 at underground floors and 9 at ground floors) frequented by workers and/or the public. The survey parameters considered in the analysis of the results were: floor types, wall cladding materials, number of openings, door/window opening duration for air exchange. Radon levels were found to be between 17 and 680 Bq/m3, with an average value of 130 Bq/m3 and a standard deviation of 120 Bq/m3. About 7% of the results gave a radon activity concentration above 300 Bq/m3. The analysis showed that the floor level and air exchange have the most significant influence. This study highlighted the importance of the assessment of indoor radon levels for work environments in particular, to protect the workers and public from radon-induced health effects.