Background: Coxiella burnetii, the bacterium causing Q fever, is an obligate intracellular biosafety level 3 agent. Detection and quantification of these bacteria with conventional methods is time consuming and dangerous. During the last years, several PCR based diagnostic assays were developed to detect C. burnetii DNA in cell cultures and clinical samples. We developed and evaluated TaqMan-based real-time PCR assays that targeted the singular icd (isocitrate dehydrogenase) gene and the transposase of the IS1111a element present in multiple copies in the C. burnetii genome. Results: To evaluate the precision of the icd and IS1111 real-time PCR assays, we performed different PCR runs with independent DNA dilutions of the C. burnetii Nine Mile RSA493 strain. The results showed very low variability, indicating efficient reproducibility of both assays. Using probit analysis, we determined that the minimal number of genome equivalents per reaction that could be detected with a 95% probability was 10 for the icd marker and 6.5 for the IS marker. Plasmid standards with cloned icd and IS1111 fragments were used to establish standard curves which were linear over a range from 10 to 107 starting plasmid copy numbers. We were able to quantify cell numbers of a diluted, heat-inactivated Coxiella isolate with a detection limit of 17 C. burnetii particles per reaction. Real-time PCR targeting both markers was performed with DNA of 75 different C. burnetii isolates originating from all over the world. Using this approach, the number of IS1111 elements in the genome of the Nine Mile strain was determined to be 23, close to 20, the number revealed by genome sequencing. In other isolates, the number of IS1111 elements varied widely (between seven and 110) and seemed to be very high in some isolates. Conclusion: We validated TaqMan-based real-time PCR assays targeting the icd and IS1111 markers of C. burnetii. The assays were shown to be specific, highly sensitive and efficiently reproducible. Cell numbers in dilutions of a C. burnetii isolate were reliably quantified. PCR quantification suggested a high variability of the number of IS1111 elements in different C. burnetii isolates, which may be useful for further phylogenetic studies.
A real-time quantitative polymerase chain reaction assay was devised to determine the load of human herpesvirus (HHV)—6A and —6B DNA in paired samples of plasma and peripheral blood leukocytes (PBL) of 25 bone marrow transplant patients. The assay detects HHV-6 DNA variants A and B in a linear range of 107–101 genome equivalents per assay. Viral DNA was measured in 336 paired DNA PBL samples and in corresponding plasma samples. HHV-6A and/or -6B DNA was detected in PBL of 23 of 25 patients and in plasma of 24 of 25 patients. HHV-6B was the predominant variant found in PBL and also was detected in the corresponding plasma. Surprisingly, only 1 of 25 patients had detectable HHV-6A DNA in PBL, although 23 of 25 patients were positive for HHV-6A DNA in plasma. HHV-6 DNA load in plasma was significantly higher for HHV-6A than for HHV-6B (P = .0066).
The principle of a capture ELISA is binding of specific capture antibodies (polyclonal or monoclonal) to the surface of a suitable 96 well plate. These immobilized antibodies are capable of specifically binding a virus present in a clinical sample. Subsequently, the captured virus is detected using a specific detection antibody. The drawback of this method is that a capture ELISA can only function for a single virus captured by the primary antibody. Human Apolipoprotein H (ApoH) or β2-glycoprotein 1 is able to poly-specifically bind viral pathogens. Replacing specific capture antibodies by ApoH should allow poly-specific capture of different viruses that subsequently could be revealed using specific detection antibodies. Thus, using a single capture ELISA format different viruses could be analysed depending on the detection antibody that is applied. In order to demonstrate that this is a valid approach we show detection of group A rotaviruses from stool samples as a proof of principle for a new method of capture ELISA that should also be applicable to other viruses.
Porcine Hokovirus (PHoV) was recently discovered in Hong Kong. This new Parvovirus of pigs is closely related to the human Parvoviruses 4 and 5 (PARV4/5) and bovine Hokovirus (BHoV). So far, nothing is known about the presence and prevalence of PHoV in regions of the world other than Hong Kong. A study was initiated to investigate PHoV in German wild boars from five different geographical regions, using a newly established quantitative real-time PCR assay. Analysis of collected liver and serum samples revealed high overall prevalence (32.7%; 51/156) of PHoV in wild boars. The prevalence differed between the regions and increased with age. Two near full-length genomes and a large fragment for three additional isolates from different regions were sequenced and used for phylogenetic analysis. The German PHoV sequences from wild boars showed a close relationship with sequences of isolates from Hong Kong.