The impact of antithrombotic regimen and platelet inhibition extent on subclinical leaflet thrombosis (SLT) detected by cardiac multidetector computed tomography (MDCT) after transcatheter aortic valve replacement (TAVR) is not well established. Hypoattenuation affecting motion (HAM) has been proposed as a surrogate marker of SLT, and is characterized by hypoattenuated leaflet thickening (HALT) and concomitant reduction in leaflet motion (RELM). We sought to investigate (i) the prevalence of HAM and HALT after TAVR detected by MDCT, (ii) the predictors of SLT, (iii) the impact of oral anticoagulant (OAC) and platelet inhibition extent assessed by platelet reactivity index vasodilator stimulated phosphoprotein (PRI-VASP) and closure time adenosine diphosphate (CT-ADP) on SLT. Of 187 consecutive patients who underwent TAVR from 1 August 2017 to 31 March 2018, 90 of them had cardiac CT at relevant follow-up. Clinical, biological, echocardiographic, procedural characteristics and treatments were collected before, at discharge, and 1 year after TAVR. P2Y12 platelet inhibition extent and primary haemostasis disorders were investigated using platelet PRI-VASP and CT-ADP point-of-care assays. Eighty-five post-TAVR CTs out of 90 were ranked for clarity and assessed with sufficient diagnostic quality. HAM was evidenced in 13 patients (15.3%) and HALT in 30 patients (35%). Procedural characteristics, including aortic valve calcium score, annulus size, or procedural heparin regimens, were equivalent between groups. Likewise, no impact of P2Y12 inhibition (PRI-VASP) nor primary haemostasis disorders (CT-ADP) on SLT could be evidenced. No impact of SLT on valve deterioration evaluated by transthoracic echocardiography (TTE) and clinical events could be established at 12 months follow-up. By multivariate analysis, lack of oral anticoagulant therapy at discharge (HR 12.130 CI 95% (1.394–150.582); p = 0.028) and higher haemoglobin levels were evidenced as the sole independent predictors of SLT. In four patients with HAM, MDCT follow-up was obtained after initiation of OAC therapy and showed a complete regression of HAM. SLT was evidenced in a sizeable proportion of patients treated by TAVR and was mainly determined by the lack of oral anticoagulant therapy. Conversely, no impact of platelet inhibition extent on SLT could be evidenced.
While cardiovascular disease has been associated with an increased risk of coronavirus disease 2019 (COVID-19), no studies have described its clinical course in patients with aortic stenosis who had undergone transcatheter aortic valve replacement (TAVR). Numerous observational studies have reported an association between the A blood group and an increased susceptibility to SARS-CoV-2 infection. Our objective was to investigate the frequency and clinical course of COVID-19 in a large sample of patients who had undergone TAVR and to determine the associations of the ABO blood group with disease occurrence and outcomes. Patients who had undergone TAVR between 2010 and 2019 were included in this study and followed-up through the recent COVID-19 outbreak. The occurrence and severity (hospitalization and/or death) of COVID-19 and their associations with the ABO blood group served as the main outcome measures. Of the 1125 patients who had undergone TAVR, 403 (36%) died before 1 January 2020, and 20 (1.8%) were lost to follow-up. The study sample therefore consisted of 702 patients. Of them, we identified 22 cases (3.1%) with COVID-19. Fourteen patients (63.6%) were hospitalized or died of disease. Multivariable analysis identified the A blood group (vs. others) as the only independent predictor of COVID-19 in patients who had undergone TAVR (odds ratio (OR) = 6.32; 95% confidence interval (CI) = 2.11−18.92; p = 0.001). The A blood group (vs. others; OR = 8.27; 95% CI = 1.83−37.43, p = 0.006) and a history of cancer (OR = 4.99; 95% CI = 1.64−15.27, p = 0.005) were significantly and independently associated with disease severity (hospitalization and/or death). We conclude that patients who have undergone TAVR frequently have a number of cardiovascular comorbidities that may work to increase the risk of COVID-19. The subgroup with the A blood group was especially prone to developing the disease and showed unfavorable outcomes.
Published data on the size-specific effective orifice area (EOA) of transcatheter heart valves (THVs) remain scarce. Here, we sought to investigate the intra-individual changes in EOA and mean transvalvular aortic gradient (MG) of the Sapien 3 (S3), CoreValve (CV), and Evolut R (EVR) prostheses both at short-term and at 1-year follow-up. The study sample consisted of 260 consecutive patients with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI). EOAs and MGs were measured with Doppler echocardiography for the following prostheses: S3 23 mm (n = 74; 28.5%), S3 26 mm (n = 67; 25.8%), S3 29 mm (n = 20; 7.7%), CV 23 mm (n = 2; 0.8%), CV 26 mm (n = 15; 5.8%), CV 29 mm (n = 24; 9.2%), CV 31 mm (n = 9; 3.5%), EVR 26 mm (n = 22; 8.5%), and EVR 29 mm (n = 27; 10.4%). Values were obtained at discharge, 1 month, 6 months, and 1 year from implantation. At discharge, EOAs were larger and MGs lower for larger-size prostheses, regardless of being balloon-expandable or self-expandable. In patients with small aortic annulus size, the hemodynamic performances of CV and EVR prostheses were superior to those of S3. However, we did not observe significant differences in terms of all-cause mortality according to THV type or size. Both balloon-expandable and self-expandable new-generation THVs show excellent hemodynamic performances without evidence of very early valve degeneration.
With respect to the transfemoral approach, transradial procedures enable a drastic reduction of bleeding events and are associated with a reduction of mortality. Radial artery spasm (RAS) is one of the most common complications and may lead to patient discomfort and procedural failure. Currently, there is no consensus on the optimal sedation protocol to avoid RAS. The aim of this study was to investigate the respective impact of opioids analgesia and inhalation sedation with a 50% nitrous oxide/oxygen premix (Kalinox) on pain and occurrence of RAS during transradial coronary procedures. Consecutive patients undergoing transradial coronary angiography were prospectively enrolled in one, single center observational study (Nouvel Hôpital Civil, Strasbourg, France). Patients received opioids analgesia or inhalation sedation with Kalinox. The primary endpoints of the study were the incidence of a pain scale ≥5/10 and the occurrence of RAS. The secondary endpoints were the incidence of side effects. A total of 325 patients were enrolled (185 in the opioids analgesia group, 140 in the Kalinox group). RAS and pain scale ≥5 rates were not significantly different in the opioids analgesia and Kalinox groups (respectively 13.5% vs. 10.0% and 16.2% vs. 11.4%). Headache was more frequently observed in the Kalinox group (6.4% vs. 0.0%; p = 0.002). By multivariate analysis, female gender, BMI <25 kg/m2, puncture difficulty, the use of plastic needle and 6F sheath were identified as independent predictors of RAS. Procedural inhalation sedation by Kalinox is as safe as opioids analgesia during transradial coronary angiography.
Background: Bleeding events are among the striking complications following transcatheter aortic valve replacement (TAVR), and bleeding prediction models are crucially warranted. Several studies have highlighted that primary hemostasis disorders secondary to persistent loss of high-molecular-weight (HMW) multimers of the von Willebrand factor (vWF) and assessed by adenosine diphosphate closure time (CT-ADP) may be a strong predictor of late major/life-threatening bleeding complications (MLBCs). Pre-existing atrial fibrillation (AF) is a frequent comorbidity in TAVR patients and potentially associated with increased bleeding events after the procedure. Objectives: This study evaluated the impact of ongoing primary hemostasis disorders, as assessed by post-procedural CT-ADP > 180 s, on clinical events after TAVR among anticoagulated AF patients. Methods: An ongoing primary hemostasis disorder was defined by post-procedure CT-ADP > 180 s. Bleeding complications were assessed according to the Valve Academic Research Consortium-2 (VARC-2) criteria. The primary endpoint was the occurrence of late MLBCs at one-year follow-up. The secondary endpoint was a composite of mortality, stroke, myocardial infarction, and rehospitalization for heart failure. Results: In total, 384 TAVR patients were included in the analysis. Of these patients, 57 patients (14.8%) had a prolongated CT-ADP > 180 s. Increased MLBCs were observed in patients with CT-ADP > 180 s (35.1% versus 1.2%; p < 0.0001). Conversely, the occurrence of the composite endpoint did not differ between the groups. Multivariate analysis identified CT-ADP > 180 s (HR 28.93; 95% CI 9.74–85.95; p < 0.0001), bleeding history, paradoxical aortic stenosis (AS), and major vascular complications following TAVR as independent predictors of late MLBCs. Conclusion: Among patients with anticoagulated AF, a post-procedural CT-ADP > 180 s was identified as a strong independent predictor of late MLBCs. These findings suggest that persistent primary hemostasis disorders contribute to a higher risk of late bleeding events and should be considered for a tailored, risk-adjusted antithrombotic therapy after TAVR.
Background: The impact of coronary artery disease (CAD) and revascularization by percutaneous coronary intervention (PCI) on prognosis in patients undergoing transcatheter aortic valve replacement (TAVR) remain debated. A dismal prognosis in patients undergoing PCI has been associated with elevated baseline SYNTAX score (bSS) and residual SYNTAX score (rSS). The objective was to investigate whether the degree of bSS and rSS impacted ischemic and bleeding events after TAVR. Methods: bSS and rSS were calculated in 311 patients admitted for TAVR. The primary outcome was the occurrence of major adverse cardiac events (MACE), a composite endpoint of myocardial infarction, stroke, cardiovascular death, or rehospitalization for heart failure. The occurrence of late major/life-threatening bleeding complications (MLBCs) and each primary endpoint individually were the secondary endpoints. Results: bSS > 22 was associated with higher occurrence of MACE (p = 0.013). rSS > 8 and bSS > 22 had no impact on overall cardiovascular mortality. rSS > 8 and bSS > 22 were associated with higher rates of myocardial infarction (p = 0.001 and p = 0.004) and late occurrence of MLBCs. Multivariate analysis showed that bSS > 22 (sHR 2.48) and rSS > 8 (sHR 2.35) remained predictors of MLBCs but not of myocardial infarction. Conclusions: Incomplete coronary revascularization and CAD burden did not impact overall and cardiac mortality but constitute predictors of late MLBCs in TAVR patients.