Jose Maria Anglada-Cantarell

Prof. Dr. Jose Maria Anglada-Cantarell

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
NPNatalia Palacios-Garzón
Natalia Palacios-Garzón
SESonia Egido-Moreno
Sonia Egido-Moreno
Raúl Ayuso‐MonteroRaúl Ayuso‐Montero
Raúl Ayuso‐Montero
Eugenio Velasco-OrtegaEugenio Velasco-Ortega
Eugenio Velasco-Ortega
JAJose Maria Anglada-Cantarell
Jose Maria Anglada-Cantarell
José López-LópezJosé López-López
José López-López
The vertical position concerning the bone in which the implants are placed has been related as one of the factors causing marginal bone loss. The objective of this study was to evaluate the bone loss that occurs before prosthetic loading around tapered internal connection (CIC) implants placed at the crestal (C) and subcrestal (S) levels. Method: A randomized clinical trial (RCT) was carried out, with a sample size of 62 implants placed in 27 patients who underwent radiological controls on the day of placement, at one month, and at 4 months, and stability was measured by resonance frequency analysis (RFA) on three occasions. Results: Bone loss in implants C and S from the time of placement (T0) and the month after (T1) was not significant (p = 0.54) (C = 0.19 mm and S = 0.15 mm). The difference between one month (T1) and four months (T2) (C = 0.17 mm and S = 0.22 mm) was not significant either (p = 0.26). The difference between the day of placement (T0) and the third and last measurement (T2) was almost null (p = 0.94) (C = 0.35 mm and S = 0.36). The overall success rate of the implants was 97.8%. The stability of the implants measured with RFA went from 70.60 (T0) to 73.16 (T1) and 74.52 (T2). Conclusions: No significant differences were found in the bone loss for implants placed at the C and S levels. The millimeters of bone loss detected in both vertical positions did not have a significant impact on the stability of the implants.

29 October 2020 in Coatings
Verified
Journal Article
Open access
PDF file
NPNatalia Palacios-Garzón
Natalia Palacios-Garzón
Raúl Ayuso‐MonteroRaúl Ayuso‐Montero
Raúl Ayuso‐Montero
ESENRIC SALAS
ENRIC SALAS
JAJose Maria Anglada-Cantarell
Jose Maria Anglada-Cantarell
José López-LópezJosé López-López
José López-López
Introduction: The prosthetic connection of implants has been related to the loss of marginal bone. The aim of this study was to evaluate bone loss around external connection (EC) and internal conical connection (ICC) implants prior to prosthetic loading. Material and methods: A randomized clinical trial (RCT) was carried out, with a sample size of 93 implants (31 EC and 62 ICC) placed in 27 patients. Radiological controls were performed and stability was measured by resonance frequency analysis (RFA) on the day of placement, at 1 month and at 4 months after the placement. Results: Bone loss in EC implants was not statistically different than in ICC implants between the time of placement (T0) and the subsequent month (T1): (EC = 0.18 mm and ICC = 0.17 mm). Between one month (T1) and four months (T2): (EC = 0.39 mm and ICC = 0.19 mm) this difference was highly significant (p = 0.00). Bone loss between T0 and T2 was significantly lower in the ICC (EC = 0.57 mm and ICC = 0.36 mm), (p = 0.01). The overall success rate of the implants was 97.8%. The stability of the implants increased from 70.69 (T0) to 73.91 (T1) and 75.32 (T2). Conclusions: ICC showed less bone loss up to the time of prosthesis placement. Such bone loss did not have a significant impact on bone stability. Long term RCTs are needed to demonstrate whether this bone loss, which is more pronounced at the beginning in EC, tends to stabilize and equate to ICC.