Tamás Haidegger

Dr. Tamás Haidegger

Obuda Universtiy, EKIK
+1
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
AFAlfred M. Franz
Alfred M. Franz
Tamás HaideggerTamás Haidegger
Tamás Haidegger
WBWolfgang Birkfellner
Wolfgang Birkfellner
KCKevin Cleary
Kevin Cleary
TPTerry M. Peters
Terry M. Peters
LMLena Maier-Hein
Lena Maier-Hein
Object tracking is a key enabling technology in the context of computer-assisted medical interventions. Allowing the continuous localization of medical instruments and patient anatomy, it is a prerequisite for providing instrument guidance to subsurface anatomical structures. The only widely used technique that enables real-time tracking of small objects without line-of-sight restrictions is electromagnetic (EM) tracking. While EM tracking has been the subject of many research efforts, clinical applications have been slow to emerge. The aim of this review paper is therefore to provide insight into the future potential and limitations of EM tracking for medical use. We describe the basic working principles of EM tracking systems, list the main sources of error, and summarize the published studies on tracking accuracy, precision and robustness along with the corresponding validation protocols proposed. State-of-the-art approaches to error compensation are also reviewed in depth. Finally, an overview of the clinical applications addressed with EM tracking is given. Throughout the paper, we report not only on scientific progress, but also provide a review on commercial systems. Given the continuous debate on the applicability of EM tracking in medicine, this paper provides a timely overview of the state-of-the-art in the field.

23 June 2022 in Proceedings of the IEEE
Verified
Journal Article
Open access
Tamás HaideggerTamás Haidegger
Tamás Haidegger
SSStefanie Speidel
Stefanie Speidel
DSDanail Stoyanov
Danail Stoyanov
RSRichard Satava
Richard Satava
Telesurgical robotics, as a technical solution for robot-assisted minimally invasive surgery (RAMIS), has become the first domain within medicosurgical robotics that achieved a true global clinical adoption. Its relative success (still at a low single-digit percentile total market penetration) roots in the particular human-in-the-loop control, in which the trained surgeon is always kept responsible for the clinical outcome achieved by the robot-actuated invasive tools. Nowadays, this paradigm is challenged by the need for improved surgical performance, traceability, and safety reaching beyond the human capabilities. Partially due to the technical complexity and the financial burden, the adoption of telesurgical robotics has not reached its full potential, by far. Apart from the absolutely market-dominating da Vinci surgical system, there are already 60+ emerging RAMIS robot types, out of which 15 have already achieved some form of regulatory clearance. This article aims to connect the technological advancement with the principles of commercialization, particularly looking at engineering components that are under development and have the potential to bring significant advantages to the clinical practice. Current RAMIS robots often do not exceed the functionalities deriving from their mechatronics, due to the lack of data-driven assistance and smart human–machine collaboration. Computer assistance is gradually gaining more significance within emerging RAMIS systems. Enhanced manipulation capabilities, refined sensors, advanced vision, task-level automation, smart safety features, and data integration mark together the inception of a new era in telesurgical robotics, infiltrated by machine learning (ML) and artificial intelligence (AI) solutions. Observing other domains, it is definite that a key requirement of a robust AI is the good quality data, derived from proper data acquisition and sharing to allow building solutions in real time based on ML. Emerging RAMIS technologies are reviewed both in a historical and a future perspective.

22 July 2010 in Surgical Endoscopy
Verified
Journal Article
Closed access
PDF file
Tamás HaideggerTamás Haidegger
Tamás Haidegger
JSJózsef Sándor
József Sándor
ZBZoltán Benyó
Zoltán Benyó

1 January 2015 in International Journal of Advanced Robotic Systems
Verified
Journal Article
Open access
MHMathias Hoeckelmann
Mathias Hoeckelmann
IRImre J. Rudas
Imre J. Rudas
PFPaolo Fiorini
Paolo Fiorini
FKFrank Kirchner
Frank Kirchner
Tamás HaideggerTamás Haidegger
Tamás Haidegger
Commercial surgical robots have been in clinical use since the mid-1990s, supporting surgeons in various tasks. In the past decades, many systems emerged as research platforms, and a few entered the global market. This paper summarizes the currently available surgical systems and research directions in the broader field of surgical robotics. The widely deployed teleoperated manipulators aim to enhance human cognitive and physical skills and provide smart tools for surgeons, while image-guided robotics focus on surpassing human limitations by introducing automated targeting and treatment delivery methods. Both concepts are discussed based on prototypes and commercial systems. Through concrete examples the possible future development paths of surgical robots are illustrated. While research efforts are taking different approaches to improve the capacity of such systems, the aim of this survey is to assess their maturity from the commercialization point of view.

1 November 2013 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
Tamás HaideggerTamás Haidegger
Tamás Haidegger
MBMarcos Barreto
Marcos Barreto
Paulo J. S. GonçalvesPaulo J. S. Gonçalves
Paulo J. S. Gonçalves
MHMaki K. Habib
Maki K. Habib
VKVeera Ragavan Sampath Kumar
Veera Ragavan Sampath Kumar
EPEdson Prestes
Edson Prestes

30 May 2013 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
László SzilágyiLászló Szilágyi
László Szilágyi
Tamás HaideggerTamás Haidegger
Tamás Haidegger
ÁLÁkos Lehotsky
Ákos Lehotsky
MNMelinda Nagy
Melinda Nagy
ECErik-Artur Csonka
Erik-Artur Csonka
DFDale Fisher
Dale Fisher
Background: Hand hygiene compliance is generally assessed by observation of adherence to the “WHO five moments” using numbers of opportunities as the denominator. The quality of the activity is usually not monitored since there is no established methodology for the routine assessment of hand hygiene technique. The aim of this study was to objectively assess hand rub coverage of staff using a novel imaging technology and to look for patterns and trends in missed areas after the use of WHO’s 6 Step technique. Methods: A hand hygiene education and assessment program targeted 5200 clinical staff over 7 days at the National University Hospital, Singapore. Participants in small groups were guided by professional trainers through 5 educational stations, which included technique-training and UV light assessment supported by digital photography of hands. Objective criteria for satisfactory hand hygiene quality were defined a priori. The database of images created during the assessment program was analyzed subsequently. Patterns of poor hand hygiene quality were identified and linked to staff demographic. Results: Despite the assessment taking place immediately after the training, only 72% of staff achieved satisfactory coverage. Failure to adequately clean the dorsal and palmar aspects of the hand occurred in 24% and 18% of the instances, respectively. Fingertips were missed by 3.5% of subjects. The analysis based on 4642 records showed that nurses performed best (77% pass), and women performed better than men (75% vs. 62%, p<0.001). Further risk indicators have been identified regarding age and occupation. Conclusion: Ongoing education and training has a vital role in improving hand hygiene compliance and technique of clinical staff. Identification of typical sites of failure can help to develop improved training.