Xichen YUAN

Dr. Xichen YUAN

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
XYXichen YUAN
Xichen YUAN
CLChen Li
Chen Li
XYXu Yin
Xu Yin
YYYang Yang
Yang Yang
Bowen JiBowen Ji
Bowen Ji
LRLi Ren
Li Ren
Biological information detection technology is mainly used for the detection of physiological and biochemical parameters closely related to human tissues and organ lesions, such as biomarkers. This technology has important value in the clinical diagnosis and treatment of chronic diseases in their early stages. Wearable biosensors can be integrated with the Internet of Things and Big Data to realize the detection, transmission, storage, and comprehensive analysis of human physiological and biochemical information. This technology has extremely wide applications and considerable market prospects in frontier fields including personal health monitoring, chronic disease diagnosis and management, and home medical care. In this review, we systematically summarized the sweat biomarkers, introduced the sweat extraction and collection methods, and discussed the application and development of epidermal wearable biosensors for monitoring biomarkers in sweat in preclinical research in recent years. In addition, the current challenges and development prospects in this field were discussed.

20 July 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
XYXichen YUAN
Xichen YUAN
OOOumaima Ouaskioud
Oumaima Ouaskioud
XYXu Yin
Xu Yin
CLChen Li
Chen Li
PMPengyi Ma
Pengyi Ma
LRLi Ren
Li Ren
Healthcare technology has allowed individuals to monitor and track various physiological and biological parameters. With the growing trend of the use of the internet of things and big data, wearable biosensors have shown great potential in gaining access to the human body, and providing additional functionality to analyze physiological and biochemical information, which has led to a better personalized and more efficient healthcare. In this review, we summarize the biomarkers in interstitial fluid, introduce and explain the extraction methods for interstitial fluid, and discuss the application of epidermal wearable biosensors for the continuous monitoring of markers in clinical biology. In addition, the current needs, development prospects and challenges are briefly discussed.

13 September 2020 in Small Methods
Verified
Journal Article
Open access
PDF file
LRLi Ren
Li Ren
XZXingwu Zhou
Xingwu Zhou
Rohollah NasiriRohollah Nasiri
Rohollah Nasiri
JFJun Fang
Jun Fang
XJXing Jiang
Xing Jiang
WSWujin Sun
Wujin Sun
Animal models and traditional cell cultures are essential tools for drug development. However, these platforms can show striking discrepancies in efficacy and side effects when compared to human trials. These differences can lengthen the drug development process and even lead to drug withdrawal from the market. The establishment of preclinical drug screening platforms that have higher relevancy to physiological conditions is desirable to facilitate drug development. Here, a heart‐on‐a‐chip platform, incorporating microgrooves and electrical pulse stimulations to recapitulate the well‐aligned structure and synchronous beating of cardiomyocytes (CMs) for drug screening, is reported. Each chip is made with facile lithographic and laser‐cutting processes that can be easily scaled up to high‐throughput format. The maturation and phenotypic changes of CMs cultured on the heart‐on‐a‐chip is validated and it can be treated with various drugs to evaluate cardiotoxicity and cardioprotective efficacy. The heart‐on‐a‐chip can provide a high‐throughput drug screening platform in preclinical drug development.

10 July 2021 in Bioelectromagnetics
Verified
Journal Article
Closed access
PDF file
ZZZheyuan Zhang
Zheyuan Zhang
YXYanru Xue
Yanru Xue
Jiancheng YangJiancheng Yang
Jiancheng Yang
PSPeng Shang
Peng Shang
XYXichen YUAN
Xichen YUAN

7 October 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
JLJiaxing Lei
Jiaxing Lei
Peng-Fei YangPeng-Fei Yang
Peng-Fei Yang
AYAi-Ling Yang
Ai-Ling Yang
YGYan-Feng Gong
Yan-Feng Gong
PSPeng Shang
Peng Shang
XYXichen YUAN
Xichen YUAN
(1) Background: Sleep problems have become one of the current serious public health issues. Pillow height affects the alignment of the cervical spine and is closely related to the mechanical environment of the cervical spine. An appropriate pillow height can provide adequate support for the head and neck to reduce the stress in the cervical spine and relax the muscles of the neck and shoulder, thereby relieving pain and improving sleep quality. (2) Methods: We reviewed the current trends, research methodologies, and determinants of pillow height evaluation, summarizing the evidences published since 1997. In particular, we scrutinized articles dealing with the physiological and mechanical characteristics of the head-neck-shoulder complex. (3) Results: Through the investigation and analysis of these articles, we presented several quantitative and objective determinants for pillow height evaluation, including cervical spine alignment, body dimension, contact pressure, and muscle activity. The measurement methods and selection criteria for these parameters are described in detail. However, the suggested range for achieving optimal cervical spine alignment, appropriate pressure distribution, and minimal muscle activity during sleep cannot yet be identified considering the lack of sufficient evidence. Moreover, there remain no firm conclusions about the optimal pillow height for the supine and lateral positions. (4) Conclusions: A comprehensive evaluation combining the above determinants provides a unique solution for ergonomic pillow design and proper pillow height selection, which can effectively promote the public sleep health. Therefore, it is necessary to develop a reasonable algorithm to weigh multiple determinants.

10 February 2021 in Coatings
Verified
Journal Article
Open access
PDF file
YZYuhao Zhou
Yuhao Zhou
Bowen JiBowen Ji
Bowen Ji
MWminghao wang
minghao wang
KZKai Zhang
Kai Zhang
SHShuaiqi Huangfu
Shuaiqi Huangfu
XYXichen YUAN
Xichen YUAN
Remarkable progress has been made in the high resolution, biocompatibility, durability and stretchability for the implantable brain-computer interface (BCI) in the last decades. Due to the inevitable damage of brain tissue caused by traditional rigid devices, the thin film devices are developing rapidly and attracting considerable attention, with continuous progress in flexible materials and non-silicon micro/nano fabrication methods. Therefore, it is necessary to systematically summarize the recent development of implantable thin film devices for acquiring brain information. This brief review subdivides the flexible thin film devices into the following four categories: planar, open-mesh, probe, and micro-wire layouts. In addition, an overview of the fabrication approaches is also presented. Traditional lithography and state-of-the-art processing methods are discussed for the key issue of high-resolution. Special substrates and interconnects are also highlighted with varied materials and fabrication routines. In conclusion, a discussion of the remaining obstacles and directions for future research is provided.