Bart De Keizer

Dr. Bart De Keizer

UMC Utrecht
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MEMattijs Elschot
Mattijs Elschot
BVBart J. Vermolen
Bart J. Vermolen
MLMarnix G. E. H. Lam
Marnix G. E. H. Lam
BKBart De Keizer
Bart De Keizer
MBMaurice A. A. J. van Den Bosch
Maurice A. A. J. van Den Bosch
HJHugo W. A. M. de Jong
Hugo W. A. M. de Jong
After yttrium-90 (90Y) microsphere radioembolization (RE), evaluation of extrahepatic activity and liver dosimetry is typically performed on 90Y Bremsstrahlung SPECT images. Since these images demonstrate a low quantitative accuracy, 90Y PET has been suggested as an alternative. The aim of this study is to quantitatively compare SPECT and state-of-the-art PET on the ability to detect small accumulations of 90Y and on the accuracy of liver dosimetry. SPECT/CT and PET/CT phantom data were acquired using several acquisition and reconstruction protocols, including resolution recovery and Time-Of-Flight (TOF) PET. Image contrast and noise were compared using a torso-shaped phantom containing six hot spheres of various sizes. The ability to detect extra- and intrahepatic accumulations of activity was tested by quantitative evaluation of the visibility and unique detectability of the phantom hot spheres. Image-based dose estimates of the phantom were compared to the true dose. For clinical illustration, the SPECT and PET-based estimated liver dose distributions of five RE patients were compared. At equal noise level, PET showed higher contrast recovery coefficients than SPECT. The highest contrast recovery coefficients were obtained with TOF PET reconstruction including resolution recovery. All six spheres were consistently visible on SPECT and PET images, but PET was able to uniquely detect smaller spheres than SPECT. TOF PET-based estimates of the dose in the phantom spheres were more accurate than SPECT-based dose estimates, with underestimations ranging from 45% (10-mm sphere) to 11% (37-mm sphere) for PET, and 75% to 58% for SPECT, respectively. The differences between TOF PET and SPECT dose-estimates were supported by the patient data. In this study we quantitatively demonstrated that the image quality of state-of-the-art PET is superior over Bremsstrahlung SPECT for the assessment of the 90Y microsphere distribution after radioembolization.

27 November 2013 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
HAHugo J. A. Adams
Hugo J. A. Adams
Thomas C. KweeThomas C. Kwee
Thomas C. Kwee
BKBart De Keizer
Bart De Keizer
RFRob Fijnheer
Rob Fijnheer
JKJohn M. H. de Klerk
John M. H. de Klerk
RNRutger A. J. Nievelstein
Rutger A. J. Nievelstein

17 January 2015 in European Radiology
Verified
Journal Article
Closed access
PDF file
CBConstantinus F. Buckens
Constantinus F. Buckens
GDGawein Dijkhuis
Gawein Dijkhuis
BKBart De Keizer
Bart De Keizer
HVHarald J. Verhaar
Harald J. Verhaar
PJPim A. de Jong
Pim A. de Jong

18 December 2013 in Annals of Oncology
Verified
Journal Article
Open access
PDF file
HAH. J. A. Adams
H. J. A. Adams
Thomas C. KweeThomas C. Kwee
Thomas C. Kwee
BKBart De Keizer
Bart De Keizer
RFR. Fijnheer
R. Fijnheer
JKJ. M. H. de Klerk
J. M. H. de Klerk
RNR. A. J. Nievelstein
R. A. J. Nievelstein
This study aimed to systematically review and meta-analyze published data on the diagnostic performance of 18F-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG-PET/CT) in detecting bone marrow involvement in newly diagnosed Hodgkin lymphoma, and to determine whether FDG-PET/CT can replace blind bone marrow biopsy (BMB) in these patients. The PubMed/Medline and Embase databases were systematically searched for relevant studies. Methodological quality of each study was assessed. Sensitivities and specificities of FDG-PET/CT in individual studies were calculated and underwent meta-analysis with a random effects model. A summary receiver operating characteristic curve (sROC) was constructed with the Moses–Shapiro–Littenberg method. The weighted summary proportion of FDG-PET/CT-negative patients with a positive BMB among all cases was calculated under the fixed effects model. Nine eligible studies, comprising a total of 955 patients with newly diagnosed Hodgkin lymphoma, were included. Overall, the studies were of moderate methodological quality. The sensitivity and specificity of FDG-PET/CT for the detection of bone marrow involvement ranged from 87.5% to 100% and from 86.7% to 100%, respectively, with pooled estimates of 96.9% [95% confidence interval (CI) 93.0% to 99.0%] and 99.7% (95% CI 98.9% to 100%), respectively. The area under the sROC curve was 0.9860. The weighted summary proportion of FDG-PET/CT-negative patients with a positive BMB among all cases was 1.1% (95% CI 0.6% to 2.0%). Although the methodological quality of studies that were included in this systematic review and meta-analysis was moderate, the current evidence suggests that FDG-PET/CT may be an appropriate method to replace BMB in newly diagnosed Hodgkin lymphoma.

16 January 2008 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
BKBart De Keizer
Bart De Keizer
MAMaarten O. van Aken
Maarten O. van Aken
RFRichard A. Feelders
Richard A. Feelders
WHWouter W. de Herder
Wouter W. de Herder
BKBoen L. R. Kam
Boen L. R. Kam
DKDik J. Kwekkeboom
Dik J. Kwekkeboom
Introduction Receptor radionuclide therapy is a promising treatment modality for patients with neuroendocrine tumors for whom alternative treatments are limited. The aim of this study was to investigate the incidence of hormonal crises after therapy with the radiolabeled somatostatin analogue [177Lu-DOTA0,Tyr3]octreotate (177Lu-octreotate). Materials and methods All 177Lu-octreotate treatments between January 2000 and January 2007 were investigated. Four hundred seventy-six patients with gastroenteropancreatic neuroendocrine tumors and three patients with metastatic pheochromocytoma were included for analysis. Results Four hundred seventy-nine patients received a total of 1,693 administrations of 177Lu-octreotate. Six of 479 patients (1%) developed severe symptoms because of massive release of bioactive substances after the first cycle of 177Lu-octreotate. One patient had a metastatic hormone-producing small intestinal carcinoid; two patients had metastatic, hormone-producing bronchial carcinoids; two patients had vasoactive intestinal polypeptide-producing pancreatic endocrine tumors (VIPomas); and one patient had a metastatic pheochromocytoma. With adequate treatment, all patients eventually recovered. Conclusion Hormonal crises after 177Lu-octreotate therapy occur in 1% of patients. Generally, 177Lu-octreotate therapy is well tolerated.

16 April 2016 in Langenbeck's Archives of Surgery
Verified
Journal Article
Open access
PDF file
WKWouter P Kluijfhout
Wouter P Kluijfhout
JPJesse D. Pasternak
Jesse D. Pasternak
FDFrederick Thurston Drake
Frederick Thurston Drake
TBToni Beninato
Toni Beninato
JGJessica E. Gosnell
Jessica E. Gosnell
ISInsoo Suh
Insoo Suh
Purpose The great spatial and temporal resolution of positron emission tomography might provide the answer for patients with primary hyperparathyroidism (pHPT) and non-localized parathyroid glands. We performed a systematic review of the evidence regarding all investigated tracers. Methods A study was considered eligible when the following criteria were met: (1) adults ≥17 years old with non-familial pHPT, (2) evaluation of at least one PET isotope, and (3) post-surgical and pathological diagnosis as the gold standard. Performance was expressed in sensitivity and PPV. Results Twenty-four papers were included subdivided by radiopharmaceutical: 14 studies investigated l-[11C]Methionine (11C-MET), one [11C]2-hydroxy-N,N,N-trimethylethanamium (11C-CH), six 2-deoxy-2-[18F]fluoro-d-glucose (18F-FDG), one 6-[18F] fluoro-l-DOPA (18F-DOPA), and three N-[(18F)Fluoromethyl]-2-hydroxy-N,N-dimethylethanaminium (18F-FCH). The 14 studies investigating MET included a total of 327 patients with 364 lesions. Sensitivity for the detection of a lesion in the correct quadrant had a pooled estimate of 69 % (95 % CI 60–78 %). Heterogeneity was overall high with I2 of 51 % (p = 0.01) for all 14 studies. Pooled PPV ranged from 91 to 100 % with a pooled estimate of 98 % (95 % CI 96–100 %). Of the other investigated tracers, 18-FCH seems the most promising with high diagnostic performance. Conclusions The results of our meta-analysis show that 11C-MET PET has an overall good sensitivity and PPV and may be considered a reliable second-line imaging modality to enable minimally invasive parathyroidectomy. Our literature review suggests that 18F-FCH PET may produce even greater accuracy and should be further investigated using both low-dose CT and MRI for anatomical correlation.