Tobias Opialla

Dr. Tobias Opialla

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2020 in Metabolites
Verified
Journal Article
Open access
PDF file
TOTobias Opialla
Tobias Opialla
SKStefan Kempa
Stefan Kempa
MPMatthias Pietzke
Matthias Pietzke
Reliable analyte identification is critical in metabolomics experiments to ensure proper interpretation of data. Due to chemical similarity of metabolites (as isobars and isomers) identification by mass spectrometry or chromatography alone can be difficult. Here we show that isomeric compounds are quite common in the metabolic space as given in common metabolite databases. Further, we show that retention information can shift dramatically between different experiments decreasing the value of external or even in-house compound databases. As a consequence the retention information in compound databases should be updated regularly, to allow a reliable identification. To do so we present a feasible and budget conscious method to guarantee updates of retention information on a regular basis using well designed compound mixtures. For this we combine compounds in “Ident-Mixes”, showing a way to distinctly identify chemically similar compounds through combinatorics and principle of exclusion. We illustrate the feasibility of this approach by comparing Gas chromatography (GC)–columns with identical properties from three different vendors and by creating a compound database from measuring these mixtures by Liquid chromatography–mass spectrometry (LC–MS). The results show the high influence of used materials on retention behavior and the ability of our approach to generate high quality identifications in a short time.

21 August 2019 in Metabolites
Verified
Journal Article
Open access
PDF file
NBNico Borgsmueller
Nico Borgsmueller
YGYoann Gloaguen
Yoann Gloaguen
TOTobias Opialla
Tobias Opialla
EBEric Blanc
Eric Blanc
ESEmilie Sicard
Emilie Sicard
KJKirwan Jennifer
Kirwan Jennifer
Lack of reliable peak detection impedes automated analysis of large-scale gas chromatography-mass spectrometry (GC-MS) metabolomics datasets. Performance and outcome of individual peak-picking algorithms can differ widely depending on both algorithmic approach and parameters, as well as data acquisition method. Therefore, comparing and contrasting between algorithms is difficult. Here we present a workflow for improved peak picking (WiPP), a parameter optimising, multi-algorithm peak detection for GC-MS metabolomics. WiPP evaluates the quality of detected peaks using a machine learning-based classification scheme based on seven peak classes. The quality information returned by the classifier for each individual peak is merged with results from different peak detection algorithms to create one final high-quality peak set for immediate down-stream analysis. Medium- and low-quality peaks are kept for further inspection. By applying WiPP to standard compound mixes and a complex biological dataset, we demonstrate that peak detection is improved through the novel way to assign peak quality, an automated parameter optimisation, and results in integration across different embedded peak picking algorithms. Furthermore, our approach can provide an impartial performance comparison of different peak picking algorithms. WiPP is freely available on GitHub (https://github.com/bihealth/WiPP) under MIT licence.

16 March 2011 in Analytica Chimica Acta
Verified
Journal Article
Closed access
GBGabor Balizs
Gabor Balizs
CWChristoph Weise
Christoph Weise
CRChristel Rozycki
Christel Rozycki
TOTobias Opialla
Tobias Opialla
SSStefanie Sawada
Stefanie Sawada
ALAlfonso Lampen
Alfonso Lampen

18 December 2021 in Metabolites
Verified
Journal Article
Open access
PDF file
RFRaphaela Fritsche
Raphaela Fritsche
YGYoann Gloaguen
Yoann Gloaguen
ABAnna Bauer
Anna Bauer
TOTobias Opialla
Tobias Opialla
SKStefan Kempa
Stefan Kempa
JKJennifer A. Kirwan
Jennifer A. Kirwan
Using manual derivatization in gas chromatography-mass spectrometry samples have varying equilibration times before analysis which increases technical variability and limits the number of potential samples analyzed. By contrast, automated derivatization methods can derivatize and inject each sample in an identical manner. We present a fully automated (on-line) derivatization method used for targeted analysis of different matrices. We describe method optimization and compare results from using off-line and on-line derivatization protocols, including the robustness and reproducibility of the methods. Our final parameters for the derivatization process were 20 µL of methoxyamine (MeOx) in pyridine for 60 min at 30 °C followed by 80 µL N-Methyl-N-trimethylsilyltrifluoracetamide (MSTFA) for 30 min at 30 °C combined with 4 h of equilibration time. The repeatability test in plasma and liver revealed a median relative standard deviation (RSD) of 16% and 10%, respectively. Serum samples showed a consistent intra-batch median RSD of 20% with an inter-batch variability of 27% across three batches. The direct comparison of on-line versus off-line demonstrated that on-line was fit for purpose and improves repeatability with a measured median RSD of 11% compared to 17% using the same method off-line. In summary, we recommend that optimized on-line methods may improve results for metabolomics and should be used where available.

10 March 2023 in Frontiers in Molecular Biosciences
Verified
Journal Article
Open access
TOTobias Opialla
Tobias Opialla
BGBenjamin Gollasch
Benjamin Gollasch
PKPeter H. J. L. Kuich
Peter H. J. L. Kuich
LKLars Klug
Lars Klug
GRGabriele Rahn
Gabriele Rahn
SKStefan Kempa
Stefan Kempa
Corrigendum: Exercise blood-drop metabolic profiling links metabolism with perceived exertion