Francisco Zamora-Arellano

Mr. Francisco Zamora-Arellano

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2020 in Electronics
Verified
Journal Article
Open access
PDF file
FZFrancisco Zamora-Arellano
Francisco Zamora-Arellano
OBOscar Lopez Bonilla
Oscar Lopez Bonilla
EGEnrique García Guerrero
Enrique García Guerrero
Jesús Everardo Olguín-TiznadoJesús Everardo Olguín-Tiznado
Jesús Everardo Olguín-Tiznado
Everardo Inzunza-GonzalezEverardo Inzunza-Gonzalez
Everardo Inzunza-Gonzalez
Esteban Tlelo-CuautleEsteban Tlelo-Cuautle
Esteban Tlelo-Cuautle
Electrical impedance tomography (EIT) is a useful procedure with applications in industry and medicine, particularly in the lungs and brain area. In this paper, the development of a portable, reliable and low-cost EIT system for image reconstruction by using an embedded system (ES) is introduced herein. The novelty of this article is the hardware development of a complete low-cost EIT system, as well as three simple and efficient algorithms that can be implemented on ES. The proposed EIT system applies the adjacent voltage method, starting with an impedance acquisition stage that sends data to a Raspberry Pi 4 (RPi4) as ES. To perform the image reconstruction, a user interface was developed by using GNU Octave for RPi4 and the EIDORS library. A statistical analysis is performed to determine the best average value from the samples measured by using an analog-to-digital converter (ADC) with a capacity of 30 kSPS and 24-bit resolution. The tests for the proposed EIT system were performed using materials such as metal, glass and an orange to simulate its application in food industry. Experimental results show that the statistical median is more accurate with respect to the real voltage measurement; however, it represents a higher computational cost. Therefore, the mean is calculated and improved by discarding data values in a transitory state, achieving better accuracy than the median to determine the real voltage value, enhancing the quality of the reconstructed images. A performance comparison between a personal computer (PC) and RPi4 is presented. The proposed EIT system offers an excellent cost-benefit ratio with respect to a traditional PC, taking into account precision, accuracy, energy consumption, price, light weight, size, portability and reliability. The proposed EIT system has potential application in mechanical ventilation, food industry and structural health monitoring.

2 November 2020 in Electronics
Verified
Journal Article
Open access
PDF file
BFBerenice Fong
Berenice Fong
EGEnrique García Guerrero
Enrique García Guerrero
DMDavid A. Mejia
David A. Mejia
OBOscar Lopez Bonilla
Oscar Lopez Bonilla
Luis Jesús Villarreal-GómezLuis Jesús Villarreal-Gómez
Luis Jesús Villarreal-Gómez
Everardo Inzunza-GonzalezEverardo Inzunza-Gonzalez
Everardo Inzunza-Gonzalez
The use of a back-propagation artificial neural network (ANN) to systematize the reliability of a Deep Vein Thrombosis (DVT) diagnostic by using Wells’ criteria is introduced herein. In this paper, a new ANN model is proposed to improve the Accuracy when dealing with a highly unbalanced dataset. To create the training dataset, a new data augmentation algorithm based on statistical data known as the prevalence of DVT of real cases reported in literature and from the public hospital is proposed. The above is used to generate one dataset of 10,000 synthetic cases. Each synthetic case has nine risk factors according to Wells’ criteria and also the use of two additional factors, such as gender and age, is proposed. According to interviews with medical specialists, a training scheme was established. In addition, a new algorithm is presented to improve the Accuracy and Sensitivity/Recall. According to the proposed algorithm, two thresholds of decision were found, the first one is 0.484, which is to improve Accuracy. The other one is 0.138 to improve Sensitivity/Recall. The Accuracy achieved is 90.99%, which is greater than that obtained with other related machine learning methods. The proposed ANN model was validated performing the k-fold cross validation technique using a dataset with 10,000 synthetic cases. The test was performed by using 59 real cases obtained from a regional hospital, achieving an Accuracy of 98.30%.