Hiroshi Ishihata

Dr. Hiroshi Ishihata

Division of Periodontology and Endodontology, Department of Oral Biology, Tohoku University Graduate School of Dentistry

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2020 in Materials
Verified
Journal Article
Open access
PDF file
JZJingyu Zhang
Jingyu Zhang
YSYukihiko Sakisaka
Yukihiko Sakisaka
HIHiroshi Ishihata
Hiroshi Ishihata
KMKentaro Maruyama
Kentaro Maruyama
ENEiji Nemoto
Eiji Nemoto
SYSatoru Yamada
Satoru Yamada
The surface topography of Titanium (Ti) combined toughness and biocompatibility affects the attachment and migration of cells. Limited information of morphological characteristics, formed by precise machining in micron order, is currently available on the Ti that could promote osteoconduction. In the present study, a pure Ti membrane was pierced with precise 25 μm square holes at 75 μm intervals and appear burrs at the edge of aperture. We defined the surface without burrs as the “Head side” and that with burrs as the “Tail side”. The effects of the machining microtopography on the proliferation and differentiation of the preosteoblasts (MC3T3-E1 cells) were investigated. The cells were more likely to migrate to, and accumulate in, the aperture of holes on the head side, but grew uniformly regardless of holes on the tail side. The topography on the both surfaces increased osteopontin gene expression levels. Osteocalcin expression levels were higher on the head side than one on the blank scaffold and tail side (p < 0.05). The osteocalcin protein expression levels were higher on the tail side than on the head side after 21 days of cultivation, and were comparable to the proportion of the calcified area (p < 0.05). These results demonstrate the capacity of a novel microporous Ti membrane fabricated using a precise mechanical punching process to promote cell proliferation and activity.

17 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
HHHiroshi Hasegawa
Hiroshi Hasegawa
TKTetsuharu Kaneko
Tetsuharu Kaneko
MEManabu Endo
Manabu Endo
CKChihiro Kanno
Chihiro Kanno
MYMorio Yamazaki
Morio Yamazaki
HIHiroshi Ishihata
Hiroshi Ishihata
Acute-type lateral ridge defects (25 mm × 6 mm × 5 mm) were bilaterally created in the mandibles of four dogs (two defects per animal). The defects were reconstructed with particulate autologous bone and covered with a microperforated titanium membrane (Ti-honeycomb membrane, TiHM) or an existing conventional titanium mesh as control. The samples were dissected after 16 weeks postoperatively and processed for radiographic, histologic, and histomorphometric analyses. Regenerated tissue and bone volume were significantly larger in the TiHM group than in the control group (p = 0.05; p = 0.049). In contrast, bone mineral density was similar between the two groups. Histomorphometric analysis revealed that the regenerated bone area and calcific osseous area were larger in the TiHM group than in the control group; however, the differences were not significant. The efficacy of TiHM was generally satisfactory with the potential to become a standard tool for the GBR procedure; however, early membrane exposure will be a major problem to overcome.

11 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
HSHideaki Sato
Hideaki Sato
HIHiroshi Ishihata
Hiroshi Ishihata
YKYutaka Kameyama
Yutaka Kameyama
RSRyokichi Shimpo
Ryokichi Shimpo
SKSatoshi Komasa
Satoshi Komasa
Oral dysfunction due to peri-implantitis and shortened life of implants has become a major concern. Self-care and removal of oral biofilms by professional mechanical tooth cleaning (PMTC) are indispensable for its prevention. However, if the surface roughness of the implant is increased, it may result in the adhesion of biofilm in the oral cavity. Therefore, the PMTC method can serve for long-term implant management. Calcium carbonate (CaCO3) has been used as a cleaning method for implant surfaces; however, there is concern that the implant surface roughness could increase due to particle collision. Therefore, in this study, to establish a blasting cleaning method that does not adversely affect the implant surface, a new blasting cleaning method using agar particles was devised and its practical application examined. When the simulated stains were blasted with white alumina (WA) abrasive grains and CaCO3 particles, the simulated stains were almost removed, the surface roughness changed to a satin-finished surface—which was thought to be due to fine scratches—and the surface roughness increased. Most of the simulated stains were removed on the surface of the sample blasted with glycine particles and agar particles. Conversely, the gloss of the sample surface was maintained after cleaning, and the increase in surface roughness was slight.

30 January 2023 in Materials
Verified
Journal Article
Open access
PDF file
YSYukihiko Sakisaka
Yukihiko Sakisaka
HIHiroshi Ishihata
Hiroshi Ishihata
KMKentaro Maruyama
Kentaro Maruyama
ENEiji Nemoto
Eiji Nemoto
SCShigeki Chiba
Shigeki Chiba
SYSatoru Yamada
Satoru Yamada
In vitro studies on adherent cells require a process of passage to dissociate the cells from the culture substrate using enzymes or other chemical agents to maintain cellular activity. However, these proteolytic enzymes have a negative influence on the viability and phenotype of cells. The mesenchymal stem cell (MSC)-like cell line, C3H10T1/2, adhered, migrated, and proliferated to the same extent on newly designed microporous titanium (Ti) membrane and conventional culture dish, and spontaneous transfer to another substrate without enzymatic or chemical dissociation was achieved. The present study pierced a 10 μm-thick pure Ti sheet with 25 μm square holes at 75 μm intervals to create a dense porous structure with biomimetic topography. The pathway of machined holes allowed the cells to access both sides of the membrane frequently. In a culture with Ti membranes stacked above- and below-seeded cells, cell migration between the neighboring membranes was confirmed using the through-holes of the membrane and contact between the membranes as migration routes. Furthermore, the cells on each membrane migrated onto the conventional culture vessel. Therefore, a cell culture system with enzyme-free passaging was developed.