Ultrasound imaging has developed into an indispensable imaging technology in medical diagnosis and treatment applications due to its unique advantages, such as safety, affordability, and convenience. With the development of data information acquisition technology, ultrasound imaging is increasingly susceptible to speckle noise, which leads to defects, such as low resolution, poor contrast, spots, and shadows, which affect the accuracy of physician analysis and diagnosis. To solve this problem, we proposed a frequency division denoising algorithm combining transform domain and spatial domain. First, the ultrasound image was decomposed into a series of sub-modal images using 2D variational mode decomposition (2D-VMD), and adaptively determined 2D-VMD parameter K value based on visual information fidelity (VIF) criterion. Then, an anisotropic diffusion filter was used to denoise low-frequency sub-modal images, and a 3D block matching algorithm (BM3D) was used to reduce noise for high-frequency images with high noise. Finally, each sub-modal image was reconstructed after processing to obtain the denoised ultrasound image. In the comparative experiments of synthetic, simulation, and real images, the performance of this method was quantitatively evaluated. Various results show that the ability of this algorithm in denoising and maintaining structural details is significantly better than that of other algorithms.
25 November 2020 in Mathematical Problems in Engineering
We studied the chaotic peculiarities of magnetic-mechanical coupled system of GMA. Based on the working principle of GMA and according to Newton’s second law of motion, first piezomagnetic equation, disk spring design theory, and structural dynamics principle of GMA, the present study established a GMA magnetic-mechanical coupled system model. By carrying out data modeling of this coupled system model, the bifurcation chart of the system with the variation of damping factor, excitation force, and exciting frequency parameters as well as the homologous offset oscillogram, phase plane trace chart, and Poincaré diagram was obtained, and the chaotic peculiarities of the system were analyzed. The influence of parametric errors on the coupled system was studied. The analytical results showed that the oscillation equation of the GMA magnetic-mechanical coupled system had nonlinearity and the movement morphology was complicated and diversified. By adjusting the damping factor, exciting frequency, and excitation force parameters of the system, the system could work under the stable interval, which provided theoretical support for the stability design of GMA.